Cargando…

First successful transcatheter valve-in-valve implantation into a failed mechanical prosthetic aortic valve facilitated by fracturing of the leaflets: a case report

BACKGROUND: Degenerated and failed bioprosthetic cardiac valves can safely be treated with transcatheter valve-in-valve implantation in patients at high risk for reoperation. So far, non-functional mechanical valves must be treated with a surgical redo. Breaking the carbon leaflets before implanting...

Descripción completa

Detalles Bibliográficos
Autores principales: Butter, Christian, Kühnel, Ralf-Uwe, Hölschermann, Frank
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8323064/
https://www.ncbi.nlm.nih.gov/pubmed/34345763
http://dx.doi.org/10.1093/ehjcr/ytab130
_version_ 1783731171834724352
author Butter, Christian
Kühnel, Ralf-Uwe
Hölschermann, Frank
author_facet Butter, Christian
Kühnel, Ralf-Uwe
Hölschermann, Frank
author_sort Butter, Christian
collection PubMed
description BACKGROUND: Degenerated and failed bioprosthetic cardiac valves can safely be treated with transcatheter valve-in-valve implantation in patients at high risk for reoperation. So far, non-functional mechanical valves must be treated with a surgical redo. Breaking the carbon leaflets before implanting a transcatheter valve into the remaining ring has never been described before. CASE SUMMARY: Here, we present the case of a 65-year-old male patient with severe heart failure, poor left ventricular function based on a fully immobile disc of his mechanical bileaflet aortic valve implanted 7 years ago. After the heart team declined to reoperate the patient due to his extremely high risk, we considered a transcatheter valve-in-valve implantation as the ultimate treatment approach. After successful interventional cracking of the leaflets in vitro, this approach, together with implanting a balloon-expandable transcatheter aortic valve replacement (TAVR) into the remaining ring, was performed under cerebral protection. The intervention resulted in a fully functional TAVR, improvement of heart function, and early discharge from the hospital. DISCUSSION: This case demonstrates the possibility to implant a transcatheter valve successfully into a non-functional mechanical bileaflet aortic prosthesis after fracturing the carbon discs while the brain is protected by a filter system. Critical steps of the procedure were identified. This new therapeutic approach might be offered to a limited patient cohort who is not eligible for a surgical redo.
format Online
Article
Text
id pubmed-8323064
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-83230642021-08-02 First successful transcatheter valve-in-valve implantation into a failed mechanical prosthetic aortic valve facilitated by fracturing of the leaflets: a case report Butter, Christian Kühnel, Ralf-Uwe Hölschermann, Frank Eur Heart J Case Rep Case Report BACKGROUND: Degenerated and failed bioprosthetic cardiac valves can safely be treated with transcatheter valve-in-valve implantation in patients at high risk for reoperation. So far, non-functional mechanical valves must be treated with a surgical redo. Breaking the carbon leaflets before implanting a transcatheter valve into the remaining ring has never been described before. CASE SUMMARY: Here, we present the case of a 65-year-old male patient with severe heart failure, poor left ventricular function based on a fully immobile disc of his mechanical bileaflet aortic valve implanted 7 years ago. After the heart team declined to reoperate the patient due to his extremely high risk, we considered a transcatheter valve-in-valve implantation as the ultimate treatment approach. After successful interventional cracking of the leaflets in vitro, this approach, together with implanting a balloon-expandable transcatheter aortic valve replacement (TAVR) into the remaining ring, was performed under cerebral protection. The intervention resulted in a fully functional TAVR, improvement of heart function, and early discharge from the hospital. DISCUSSION: This case demonstrates the possibility to implant a transcatheter valve successfully into a non-functional mechanical bileaflet aortic prosthesis after fracturing the carbon discs while the brain is protected by a filter system. Critical steps of the procedure were identified. This new therapeutic approach might be offered to a limited patient cohort who is not eligible for a surgical redo. Oxford University Press 2021-07-30 /pmc/articles/PMC8323064/ /pubmed/34345763 http://dx.doi.org/10.1093/ehjcr/ytab130 Text en © The Author(s) 2021. Published by Oxford University Press on behalf of the European Society of Cardiology. https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle Case Report
Butter, Christian
Kühnel, Ralf-Uwe
Hölschermann, Frank
First successful transcatheter valve-in-valve implantation into a failed mechanical prosthetic aortic valve facilitated by fracturing of the leaflets: a case report
title First successful transcatheter valve-in-valve implantation into a failed mechanical prosthetic aortic valve facilitated by fracturing of the leaflets: a case report
title_full First successful transcatheter valve-in-valve implantation into a failed mechanical prosthetic aortic valve facilitated by fracturing of the leaflets: a case report
title_fullStr First successful transcatheter valve-in-valve implantation into a failed mechanical prosthetic aortic valve facilitated by fracturing of the leaflets: a case report
title_full_unstemmed First successful transcatheter valve-in-valve implantation into a failed mechanical prosthetic aortic valve facilitated by fracturing of the leaflets: a case report
title_short First successful transcatheter valve-in-valve implantation into a failed mechanical prosthetic aortic valve facilitated by fracturing of the leaflets: a case report
title_sort first successful transcatheter valve-in-valve implantation into a failed mechanical prosthetic aortic valve facilitated by fracturing of the leaflets: a case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8323064/
https://www.ncbi.nlm.nih.gov/pubmed/34345763
http://dx.doi.org/10.1093/ehjcr/ytab130
work_keys_str_mv AT butterchristian firstsuccessfultranscathetervalveinvalveimplantationintoafailedmechanicalprostheticaorticvalvefacilitatedbyfracturingoftheleafletsacasereport
AT kuhnelralfuwe firstsuccessfultranscathetervalveinvalveimplantationintoafailedmechanicalprostheticaorticvalvefacilitatedbyfracturingoftheleafletsacasereport
AT holschermannfrank firstsuccessfultranscathetervalveinvalveimplantationintoafailedmechanicalprostheticaorticvalvefacilitatedbyfracturingoftheleafletsacasereport