Cargando…

A Randomized, Open-Label Comparison of Once-Weekly Insulin Icodec Titration Strategies Versus Once-Daily Insulin Glargine U100

OBJECTIVE: Insulin icodec is a novel once-weekly basal insulin analog. This trial investigated the efficacy and safety of icodec using different once-weekly titration algorithms. RESEARCH DESIGN AND METHODS: This was a phase 2, randomized, open-label, 16-week, treat-to-target study. Insulin-naive ad...

Descripción completa

Detalles Bibliográficos
Autores principales: Lingvay, Ildiko, Buse, John B., Franek, Edward, Hansen, Melissa V., Koefoed, Mette M., Mathieu, Chantal, Pettus, Jeremy, Stachlewska, Karolina, Rosenstock, Julio
Formato: Online Artículo Texto
Lenguaje:English
Publicado: American Diabetes Association 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8323172/
https://www.ncbi.nlm.nih.gov/pubmed/33875484
http://dx.doi.org/10.2337/dc20-2878
Descripción
Sumario:OBJECTIVE: Insulin icodec is a novel once-weekly basal insulin analog. This trial investigated the efficacy and safety of icodec using different once-weekly titration algorithms. RESEARCH DESIGN AND METHODS: This was a phase 2, randomized, open-label, 16-week, treat-to-target study. Insulin-naive adults (n = 205) with type 2 diabetes and HbA(1c) 7–10% while treated with oral glucose-lowering medications initiated once-weekly icodec titrations A (prebreakfast self-measured blood glucose target 80–130 mg/dL; adjustment ±21 units/week; n = 51), B (80–130 mg/dL; ±28 units/week; n = 51), or C (70–108 mg/dL; ±28 units/week; n = 52), or once-daily insulin glargine 100 units/mL (IGlar U100) (80–130 mg/dL; ±4 units/day; n = 51), all titrated weekly. Percentage of time in range (TIR) (70–180 mg/dL) during weeks 15 and 16 was measured using continuous glucose monitoring. RESULTS: TIR improved from baseline (means: A, 57.0%; B, 55.2%; C, 51.0%; IGlar U100, 55.3%) to weeks 15 and 16 (estimated mean: A, 76.6%; B, 83.0%; C, 80.9%; IGlar U100, 75.9%). TIR was greater for titration B than for IGlar U100 (estimated treatment difference 7.08%-points; 95% CI 2.12 to 12.04; P = 0.005). No unexpected safety signals were observed. Level 2 hypoglycemia (<54 mg/dL) was low in all groups (0.05, 0.15, 0.38, 0.00 events per patient-year of exposure for icodec titrations A, B, and C and IGlar U100, respectively), with no episodes of severe hypoglycemia. CONCLUSIONS: Once-weekly icodec was efficacious and well tolerated across all three titration algorithms investigated. The results for icodec titration A (80–130 mg/dL; ±21 units/week) displayed the best balance between glycemic control and risk of hypoglycemia.