Cargando…

Early warning of citric acid overdose and timely adjustment of regional citrate anticoagulation based on machine learning methods

BACKGROUND: Regional citrate anticoagulation (RCA) is an important local anticoagulation method during bedside continuous renal replacement therapy. To improve patient safety and achieve computer assisted dose monitoring and control, we took intensive care units patients into cohort and aiming at de...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Huan, Ma, Yingying, Hong, Na, Wang, Hao, Su, Longxiang, Liu, Chun, He, Jie, Jiang, Huizhen, Long, Yun, Zhu, Weiguo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8323216/
https://www.ncbi.nlm.nih.gov/pubmed/34330247
http://dx.doi.org/10.1186/s12911-021-01489-8
Descripción
Sumario:BACKGROUND: Regional citrate anticoagulation (RCA) is an important local anticoagulation method during bedside continuous renal replacement therapy. To improve patient safety and achieve computer assisted dose monitoring and control, we took intensive care units patients into cohort and aiming at developing a data-driven machine learning model to give early warning of citric acid overdose and provide adjustment suggestions on citrate pumping rate and 10% calcium gluconate input rate for RCA treatment. METHODS: Patient age, gender, pumped citric acid dose value, 5% NaHCO(3) solvent, replacement fluid solvent, body temperature value, and replacement fluid PH value as clinical features, models attempted to classify patients who received regional citrate anticoagulation into correct outcome category. Four models, Adaboost, XGBoost, support vector machine (SVM) and shallow neural network, were compared on the performance of predicting outcomes. Prediction results were evaluated using accuracy, precision, recall and F1-score. RESULTS: For classifying patients at the early stages of citric acid treatment, the accuracy of neutral networks model is higher than Adaboost, XGBoost and SVM, the F1-score of shallow neutral networks (90.77%) is overall outperformed than other models (88.40%, 82.17% and 88.96% for Adaboost, XGBoost and SVM). Extended experiment and validation were further conducted using the MIMIC-III database, the F1-scores for shallow neutral networks, Adaboost, XGBoost and SVM are 80.00%, 80.46%, 80.37% and 78.90%, the AUCs are 0.8638, 0.8086, 0.8466 and 0.7919 respectively. CONCLUSION: The results of this study demonstrated the feasibility and performance of machine learning methods for monitoring and adjusting local regional citrate anticoagulation, and further provide decision-making recommendations to clinicians point-of-care. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12911-021-01489-8.