Cargando…

Comparison of the novel VieScope with conventional and video laryngoscope in a difficult airway scenario – a randomized, controlled simulation trial

BACKGROUND: Endotracheal intubation continues to be the gold standard for securing the airway in emergency situations. Difficult intubation is still a dreadful situation when securing the airway. OBJECTIVE: To compare VieScope with Glidescope and conventional Macintosh laryngoscopy (MAC) in a simula...

Descripción completa

Detalles Bibliográficos
Autores principales: Ecker, Hannes, Kolvenbach, Simone, Stranz, Sebastian, Herff, Holger, Wetsch, Wolfgang A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8323300/
https://www.ncbi.nlm.nih.gov/pubmed/34330219
http://dx.doi.org/10.1186/s12873-021-00484-6
Descripción
Sumario:BACKGROUND: Endotracheal intubation continues to be the gold standard for securing the airway in emergency situations. Difficult intubation is still a dreadful situation when securing the airway. OBJECTIVE: To compare VieScope with Glidescope and conventional Macintosh laryngoscopy (MAC) in a simulated difficult airway situation. METHODS: In this randomized controlled simulation trial, 35 anesthesiologists performed endotracheal intubation using VieScope, GlideScope and MAC in a randomized order on a certified airway manikin with difficult airway. RESULTS: For the primary endpoint of correct tube position, no statistical difference was found (p = 0.137). Time until intubation for GlideScope (27.5 ± 20.3 s) and MAC (20.8 ± 8.1 s) were shorter compared to the VieScope (36.3 ± 10.1 s). Time to first ventilation, GlideScope (39.3 ± 21.6 s) and MAC (31.9 ± 9.5 s) were also shorter compared to the VieScope (46.5 ± 12.4 s). There was no difference shown between handling time for VieScope (20.7 ± 7.0 s) and time until intubation with GlideScope or MAC. Participants stated a better Cormack & Lehane Score with VieScope, compared to direct laryngoscopy. CONCLUSION: Rate of correct tracheal tube position was comparable between the three devices. Time to intubation and ventilation were shorter with MAC and Glidescope compared to VieScope. It did however show a comparable handling time to video laryngoscopy and MAC. It also did show a better visualization of the airway in the Cormack & Lehane Score compared to MAC. TRIAL REGISTRATION: The study was registered at the German Clinical Trials Register www.drks.de (Identifier: DRKS00024968) on March 31st 2021.