Cargando…

Evaluation of a rapid biosensor tool for measuring PAH availability in petroleum-impacted sediment

Decades of research have shown that the concentration of freely dissolved PAH (C(free)) in sediment correlates with PAH bioavailability and toxicity to aquatic organisms. Passive sampling techniques and models have been used for measuring and predicting C(free,) respectively, but these techniques re...

Descripción completa

Detalles Bibliográficos
Autores principales: Conder, Jason, Jalalizadeh, Mehregan, Luo, Hong, Bess, Amanda, Sande, Steven, Healey, Michael, Unger, Michael A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8323639/
https://www.ncbi.nlm.nih.gov/pubmed/34337585
http://dx.doi.org/10.1016/j.envadv.2021.100032
_version_ 1783731281251532800
author Conder, Jason
Jalalizadeh, Mehregan
Luo, Hong
Bess, Amanda
Sande, Steven
Healey, Michael
Unger, Michael A.
author_facet Conder, Jason
Jalalizadeh, Mehregan
Luo, Hong
Bess, Amanda
Sande, Steven
Healey, Michael
Unger, Michael A.
author_sort Conder, Jason
collection PubMed
description Decades of research have shown that the concentration of freely dissolved PAH (C(free)) in sediment correlates with PAH bioavailability and toxicity to aquatic organisms. Passive sampling techniques and models have been used for measuring and predicting C(free,) respectively, but these techniques require weeks for analytical chemical measurements and data evaluation. This study evaluated the performance of a portable, field-deployable antibody-based PAH biosensor method that can provide measurements of PAH C(free) within a matter of minutes using a small volume of mechanically-extracted sediment porewater. Four sediments with a wide range of PAHs (ΣPAH 2.4 to 307 mg/kg) derived from petroleum, creosote, and mixed urban sources, were analyzed via three methods: 1) bulk chemistry analysis; 2) ex situ sediment passive sampling; and 3) biosensor analysis of mechanically-extracted sediment porewater. Mean ΣPAH C(free) determined by the biosensor for the four sediments (3.1 to 55 μg/L) were within a factor of 1.1 (on average) compared to values determined by the passive samplers (2.0 to 52 μg/L). All mean values differed by a factor of 3 or less. The biosensor was also useful in identifying sediments that are likely to be non-toxic to benthic invertebrates. In two of the four sediments, biosensor results of 20 and 55 μg/L exceeded a potential risk-based screening level of 10 μg/L, indicating toxicity could not be ruled out. PAH Toxic Units (ΣTU) measured in these two sediments using the passive sampler C(free) results were also greater than the ΣTU threshold of 1 (6.7 and 5.8, respectively), confirming the conclusions reached with the biosensor. In contrast, the other two sediments were identified as non-toxic by both the biosensor (3.1 and 4.3 μg/L) and the passive sampler (ΣTUs of 0.34 and 0.039). These results indicate that the biosensor is a promising tool for rapid screening of sediments potentially-impacted with PAHs.
format Online
Article
Text
id pubmed-8323639
institution National Center for Biotechnology Information
language English
publishDate 2021
record_format MEDLINE/PubMed
spelling pubmed-83236392021-07-30 Evaluation of a rapid biosensor tool for measuring PAH availability in petroleum-impacted sediment Conder, Jason Jalalizadeh, Mehregan Luo, Hong Bess, Amanda Sande, Steven Healey, Michael Unger, Michael A. Environ Adv Article Decades of research have shown that the concentration of freely dissolved PAH (C(free)) in sediment correlates with PAH bioavailability and toxicity to aquatic organisms. Passive sampling techniques and models have been used for measuring and predicting C(free,) respectively, but these techniques require weeks for analytical chemical measurements and data evaluation. This study evaluated the performance of a portable, field-deployable antibody-based PAH biosensor method that can provide measurements of PAH C(free) within a matter of minutes using a small volume of mechanically-extracted sediment porewater. Four sediments with a wide range of PAHs (ΣPAH 2.4 to 307 mg/kg) derived from petroleum, creosote, and mixed urban sources, were analyzed via three methods: 1) bulk chemistry analysis; 2) ex situ sediment passive sampling; and 3) biosensor analysis of mechanically-extracted sediment porewater. Mean ΣPAH C(free) determined by the biosensor for the four sediments (3.1 to 55 μg/L) were within a factor of 1.1 (on average) compared to values determined by the passive samplers (2.0 to 52 μg/L). All mean values differed by a factor of 3 or less. The biosensor was also useful in identifying sediments that are likely to be non-toxic to benthic invertebrates. In two of the four sediments, biosensor results of 20 and 55 μg/L exceeded a potential risk-based screening level of 10 μg/L, indicating toxicity could not be ruled out. PAH Toxic Units (ΣTU) measured in these two sediments using the passive sampler C(free) results were also greater than the ΣTU threshold of 1 (6.7 and 5.8, respectively), confirming the conclusions reached with the biosensor. In contrast, the other two sediments were identified as non-toxic by both the biosensor (3.1 and 4.3 μg/L) and the passive sampler (ΣTUs of 0.34 and 0.039). These results indicate that the biosensor is a promising tool for rapid screening of sediments potentially-impacted with PAHs. 2021-01-06 2021-04 /pmc/articles/PMC8323639/ /pubmed/34337585 http://dx.doi.org/10.1016/j.envadv.2021.100032 Text en https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) )
spellingShingle Article
Conder, Jason
Jalalizadeh, Mehregan
Luo, Hong
Bess, Amanda
Sande, Steven
Healey, Michael
Unger, Michael A.
Evaluation of a rapid biosensor tool for measuring PAH availability in petroleum-impacted sediment
title Evaluation of a rapid biosensor tool for measuring PAH availability in petroleum-impacted sediment
title_full Evaluation of a rapid biosensor tool for measuring PAH availability in petroleum-impacted sediment
title_fullStr Evaluation of a rapid biosensor tool for measuring PAH availability in petroleum-impacted sediment
title_full_unstemmed Evaluation of a rapid biosensor tool for measuring PAH availability in petroleum-impacted sediment
title_short Evaluation of a rapid biosensor tool for measuring PAH availability in petroleum-impacted sediment
title_sort evaluation of a rapid biosensor tool for measuring pah availability in petroleum-impacted sediment
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8323639/
https://www.ncbi.nlm.nih.gov/pubmed/34337585
http://dx.doi.org/10.1016/j.envadv.2021.100032
work_keys_str_mv AT conderjason evaluationofarapidbiosensortoolformeasuringpahavailabilityinpetroleumimpactedsediment
AT jalalizadehmehregan evaluationofarapidbiosensortoolformeasuringpahavailabilityinpetroleumimpactedsediment
AT luohong evaluationofarapidbiosensortoolformeasuringpahavailabilityinpetroleumimpactedsediment
AT bessamanda evaluationofarapidbiosensortoolformeasuringpahavailabilityinpetroleumimpactedsediment
AT sandesteven evaluationofarapidbiosensortoolformeasuringpahavailabilityinpetroleumimpactedsediment
AT healeymichael evaluationofarapidbiosensortoolformeasuringpahavailabilityinpetroleumimpactedsediment
AT ungermichaela evaluationofarapidbiosensortoolformeasuringpahavailabilityinpetroleumimpactedsediment