Cargando…

Detection rate of breast malignancy of needle localization biopsy of breast microcalcification

OBJECTIVE: The current study aimed to retrospectively assess the cancer detection rate of needle localization biopsy of breast microcalcifications undetectable on sonography. MATERIALS AND METHODS: Patients who underwent mammography-guided needle localization biopsy of breast microcalcifications und...

Descripción completa

Detalles Bibliográficos
Autores principales: Chong, Kian-Hwee, Huang, Kuo-Feng, Kuo, Hsiu-Wen, Tzeng, I-Shiang, Chen, Jia-Hui
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8323655/
https://www.ncbi.nlm.nih.gov/pubmed/34386366
http://dx.doi.org/10.4103/tcmj.tcmj_191_20
_version_ 1783731285059960832
author Chong, Kian-Hwee
Huang, Kuo-Feng
Kuo, Hsiu-Wen
Tzeng, I-Shiang
Chen, Jia-Hui
author_facet Chong, Kian-Hwee
Huang, Kuo-Feng
Kuo, Hsiu-Wen
Tzeng, I-Shiang
Chen, Jia-Hui
author_sort Chong, Kian-Hwee
collection PubMed
description OBJECTIVE: The current study aimed to retrospectively assess the cancer detection rate of needle localization biopsy of breast microcalcifications undetectable on sonography. MATERIALS AND METHODS: Patients who underwent mammography-guided needle localization biopsy of breast microcalcifications undetectable on sonography from January 2005 to December 2017 were included in the study. Patients with incomplete medical records were excluded from the study. Patient mammograms were categorized using the Breast Imaging-Reporting and Data System (BI-RADS) assessment criteria. The percentages of benign and malignant lesions were determined by pathological examination of surgically recovered specimens. Correlation between preoperative imaging assessment and final diagnosis was investigated, and the complications associated with the procedures were recorded. RESULTS: A total of 301 needle-localized biopsies were performed under mammographic guidance. The mean age of the patients was 58.18 ± 7.73 years. The overall ductal carcinoma in situ (DCIS) and cancer detection rate was 23.3%. The proportion of patients with BI-RADS 0 category and undergoing second mammography was higher in the DCIS and cancer group. A total of 227 patients did not undergo second mammography. Of these patients, 70 demonstrated BI-RADS 4 category, 34 were diagnosed with DCIS, and 5 were diagnosed with breast cancer during subsequent follow-up. CONCLUSION: Needle-localized excision of microcalcifications undetectable on sonography has high detection rate for early stage of breast cancer with low risk of associated complications. Regular mammography is a satisfactory follow-up tool for female patients with microcalcifications in the breasts. Additional studies should be performed to compare between needle-localized excision and vacuum-assisted breast biopsy.
format Online
Article
Text
id pubmed-8323655
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-83236552021-08-11 Detection rate of breast malignancy of needle localization biopsy of breast microcalcification Chong, Kian-Hwee Huang, Kuo-Feng Kuo, Hsiu-Wen Tzeng, I-Shiang Chen, Jia-Hui Tzu Chi Med J Original Article OBJECTIVE: The current study aimed to retrospectively assess the cancer detection rate of needle localization biopsy of breast microcalcifications undetectable on sonography. MATERIALS AND METHODS: Patients who underwent mammography-guided needle localization biopsy of breast microcalcifications undetectable on sonography from January 2005 to December 2017 were included in the study. Patients with incomplete medical records were excluded from the study. Patient mammograms were categorized using the Breast Imaging-Reporting and Data System (BI-RADS) assessment criteria. The percentages of benign and malignant lesions were determined by pathological examination of surgically recovered specimens. Correlation between preoperative imaging assessment and final diagnosis was investigated, and the complications associated with the procedures were recorded. RESULTS: A total of 301 needle-localized biopsies were performed under mammographic guidance. The mean age of the patients was 58.18 ± 7.73 years. The overall ductal carcinoma in situ (DCIS) and cancer detection rate was 23.3%. The proportion of patients with BI-RADS 0 category and undergoing second mammography was higher in the DCIS and cancer group. A total of 227 patients did not undergo second mammography. Of these patients, 70 demonstrated BI-RADS 4 category, 34 were diagnosed with DCIS, and 5 were diagnosed with breast cancer during subsequent follow-up. CONCLUSION: Needle-localized excision of microcalcifications undetectable on sonography has high detection rate for early stage of breast cancer with low risk of associated complications. Regular mammography is a satisfactory follow-up tool for female patients with microcalcifications in the breasts. Additional studies should be performed to compare between needle-localized excision and vacuum-assisted breast biopsy. Wolters Kluwer - Medknow 2021-03-22 /pmc/articles/PMC8323655/ /pubmed/34386366 http://dx.doi.org/10.4103/tcmj.tcmj_191_20 Text en Copyright: © 2021 Tzu Chi Medical Journal https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Chong, Kian-Hwee
Huang, Kuo-Feng
Kuo, Hsiu-Wen
Tzeng, I-Shiang
Chen, Jia-Hui
Detection rate of breast malignancy of needle localization biopsy of breast microcalcification
title Detection rate of breast malignancy of needle localization biopsy of breast microcalcification
title_full Detection rate of breast malignancy of needle localization biopsy of breast microcalcification
title_fullStr Detection rate of breast malignancy of needle localization biopsy of breast microcalcification
title_full_unstemmed Detection rate of breast malignancy of needle localization biopsy of breast microcalcification
title_short Detection rate of breast malignancy of needle localization biopsy of breast microcalcification
title_sort detection rate of breast malignancy of needle localization biopsy of breast microcalcification
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8323655/
https://www.ncbi.nlm.nih.gov/pubmed/34386366
http://dx.doi.org/10.4103/tcmj.tcmj_191_20
work_keys_str_mv AT chongkianhwee detectionrateofbreastmalignancyofneedlelocalizationbiopsyofbreastmicrocalcification
AT huangkuofeng detectionrateofbreastmalignancyofneedlelocalizationbiopsyofbreastmicrocalcification
AT kuohsiuwen detectionrateofbreastmalignancyofneedlelocalizationbiopsyofbreastmicrocalcification
AT tzengishiang detectionrateofbreastmalignancyofneedlelocalizationbiopsyofbreastmicrocalcification
AT chenjiahui detectionrateofbreastmalignancyofneedlelocalizationbiopsyofbreastmicrocalcification