PURPOSE: This study aimed to evaluate the safety and feasibility of implanting decellularized porcine corneal lenticules in a femtosecond laser-assisted pocket for patients with advanced keratoconus and post-Lasik ectasia. METHODS: This is a retrospective clinical study of implanting a porcine corne...

Descripción completa

Detalles Bibliográficos
Autores principales: El-Massry, Ahmed, Ibrahim, Osama, Abdalla, Moones, Osman, Ihab, Mahmoud, Shahira
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Dove 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8323849/
https://www.ncbi.nlm.nih.gov/pubmed/34345164
http://dx.doi.org/10.2147/OPTH.S325666
_version_ 1783731317369733120
author El-Massry, Ahmed
Ibrahim, Osama
Abdalla, Moones
Osman, Ihab
Mahmoud, Shahira
author_facet El-Massry, Ahmed
Ibrahim, Osama
Abdalla, Moones
Osman, Ihab
Mahmoud, Shahira
author_sort El-Massry, Ahmed
collection PubMed
description PURPOSE: This study aimed to evaluate the safety and feasibility of implanting decellularized porcine corneal lenticules in a femtosecond laser-assisted pocket for patients with advanced keratoconus and post-Lasik ectasia. METHODS: This is a retrospective clinical study of implanting a porcine corneal lenticular implant in seven eyes: six with advanced keratoconus and clear cornea and one with advanced post-Lasik ectasia with a follow-up for 12 months. The lenticules are extracted from porcine tissue, subjected to a decellularization process, intensely cross-linked, sterilized and packed. They are 7 mm in diameter with at 100–120-micron thickness. The femtosecond laser was used to create an intra-stromal pocket, and then the lenticules were implanted inside the pocket followed by corneal cross-linking 3 months later for six out of seven eyes. RESULTS: Five patients had keratoconus (6 eyes) and one patient (one eye) had post-Lasik ectasia. Visual acuity improved in all patients except for one case at 6 and 12 months and this was statistically significant (P=0.002 and 0.007). At one-year follow-up, the mean central corneal thickness increased from 389.43 ± 45.41 to 429.33± 63.20 µm, the maximum keratometry decreased from 64.8 ±5.11 to 62.82± 6.16 D, the mean corneal resistance factor (CRT) increased from 5.67 to 8.42, and the total higher-order aberrations decreased from 1.80 to 1.16. Both changes in the CCT and CRF were statistically significant. One eye had wrinkles and opacified graft, and it was exchanged 3 months postoperatively. CONCLUSION: Porcine corneal lenticules implantation is immunologically safe and well tolerated in patients with advanced keratoconus and post-Lasik ectasia and may be feasible as an alternative to keratoplasty.
format Online
Article
Text
id pubmed-8323849
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Dove
record_format MEDLINE/PubMed
spelling pubmed-83238492021-08-02 Safety and Indicative Effectiveness of Porcine Corneal Lenticular Implants in Patients with Advanced Keratoconus and Post Lasik Ectasia: A Retrospective Clinical Study El-Massry, Ahmed Ibrahim, Osama Abdalla, Moones Osman, Ihab Mahmoud, Shahira Clin Ophthalmol Original Research PURPOSE: This study aimed to evaluate the safety and feasibility of implanting decellularized porcine corneal lenticules in a femtosecond laser-assisted pocket for patients with advanced keratoconus and post-Lasik ectasia. METHODS: This is a retrospective clinical study of implanting a porcine corneal lenticular implant in seven eyes: six with advanced keratoconus and clear cornea and one with advanced post-Lasik ectasia with a follow-up for 12 months. The lenticules are extracted from porcine tissue, subjected to a decellularization process, intensely cross-linked, sterilized and packed. They are 7 mm in diameter with at 100–120-micron thickness. The femtosecond laser was used to create an intra-stromal pocket, and then the lenticules were implanted inside the pocket followed by corneal cross-linking 3 months later for six out of seven eyes. RESULTS: Five patients had keratoconus (6 eyes) and one patient (one eye) had post-Lasik ectasia. Visual acuity improved in all patients except for one case at 6 and 12 months and this was statistically significant (P=0.002 and 0.007). At one-year follow-up, the mean central corneal thickness increased from 389.43 ± 45.41 to 429.33± 63.20 µm, the maximum keratometry decreased from 64.8 ±5.11 to 62.82± 6.16 D, the mean corneal resistance factor (CRT) increased from 5.67 to 8.42, and the total higher-order aberrations decreased from 1.80 to 1.16. Both changes in the CCT and CRF were statistically significant. One eye had wrinkles and opacified graft, and it was exchanged 3 months postoperatively. CONCLUSION: Porcine corneal lenticules implantation is immunologically safe and well tolerated in patients with advanced keratoconus and post-Lasik ectasia and may be feasible as an alternative to keratoplasty. Dove 2021-07-26 /pmc/articles/PMC8323849/ /pubmed/34345164 http://dx.doi.org/10.2147/OPTH.S325666 Text en © 2021 El-Massry et al. https://creativecommons.org/licenses/by-nc/3.0/This work is published and licensed by Dove Medical Press Limited. The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License (http://creativecommons.org/licenses/by-nc/3.0/ (https://creativecommons.org/licenses/by-nc/3.0/) ). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed. For permission for commercial use of this work, please see paragraphs 4.2 and 5 of our Terms (https://www.dovepress.com/terms.php).
spellingShingle Original Research
El-Massry, Ahmed
Ibrahim, Osama
Abdalla, Moones
Osman, Ihab
Mahmoud, Shahira
Safety and Indicative Effectiveness of Porcine Corneal Lenticular Implants in Patients with Advanced Keratoconus and Post Lasik Ectasia: A Retrospective Clinical Study
title Safety and Indicative Effectiveness of Porcine Corneal Lenticular Implants in Patients with Advanced Keratoconus and Post Lasik Ectasia: A Retrospective Clinical Study
title_full Safety and Indicative Effectiveness of Porcine Corneal Lenticular Implants in Patients with Advanced Keratoconus and Post Lasik Ectasia: A Retrospective Clinical Study
title_fullStr Safety and Indicative Effectiveness of Porcine Corneal Lenticular Implants in Patients with Advanced Keratoconus and Post Lasik Ectasia: A Retrospective Clinical Study
title_full_unstemmed Safety and Indicative Effectiveness of Porcine Corneal Lenticular Implants in Patients with Advanced Keratoconus and Post Lasik Ectasia: A Retrospective Clinical Study
title_short Safety and Indicative Effectiveness of Porcine Corneal Lenticular Implants in Patients with Advanced Keratoconus and Post Lasik Ectasia: A Retrospective Clinical Study
title_sort safety and indicative effectiveness of porcine corneal lenticular implants in patients with advanced keratoconus and post lasik ectasia: a retrospective clinical study
topic Original Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8323849/
https://www.ncbi.nlm.nih.gov/pubmed/34345164
http://dx.doi.org/10.2147/OPTH.S325666
work_keys_str_mv AT elmassryahmed safetyandindicativeeffectivenessofporcinecorneallenticularimplantsinpatientswithadvancedkeratoconusandpostlasikectasiaaretrospectiveclinicalstudy
AT ibrahimosama safetyandindicativeeffectivenessofporcinecorneallenticularimplantsinpatientswithadvancedkeratoconusandpostlasikectasiaaretrospectiveclinicalstudy
AT abdallamoones safetyandindicativeeffectivenessofporcinecorneallenticularimplantsinpatientswithadvancedkeratoconusandpostlasikectasiaaretrospectiveclinicalstudy
AT osmanihab safetyandindicativeeffectivenessofporcinecorneallenticularimplantsinpatientswithadvancedkeratoconusandpostlasikectasiaaretrospectiveclinicalstudy
AT mahmoudshahira safetyandindicativeeffectivenessofporcinecorneallenticularimplantsinpatientswithadvancedkeratoconusandpostlasikectasiaaretrospectiveclinicalstudy