Cargando…

Long-Term Efficacy of Ultrasound-Guided Percutaneous Laser Ablation for Low-Risk Papillary Thyroid Microcarcinoma: A 5-Year Follow-Up Study

OBJECTIVE: To evaluate the long-term efficacy and safety of ultrasound-guided percutaneous laser ablation (PLA) for the treatment of low-risk papillary thyroid microcarcinoma (PTMC). METHODS: From June 2012 to May 2015, 105 patients with solitary, pathologically confirmed PTMC lesions were treated w...

Descripción completa

Detalles Bibliográficos
Autores principales: Peng, Kai, Zhou, Ping, Liu, Wengang
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8324339/
https://www.ncbi.nlm.nih.gov/pubmed/34337037
http://dx.doi.org/10.1155/2021/6616826
_version_ 1783731374227718144
author Peng, Kai
Zhou, Ping
Liu, Wengang
author_facet Peng, Kai
Zhou, Ping
Liu, Wengang
author_sort Peng, Kai
collection PubMed
description OBJECTIVE: To evaluate the long-term efficacy and safety of ultrasound-guided percutaneous laser ablation (PLA) for the treatment of low-risk papillary thyroid microcarcinoma (PTMC). METHODS: From June 2012 to May 2015, 105 patients with solitary, pathologically confirmed PTMC lesions were treated with ultrasound-guided PLA. Nodule location, nodule volume, thyroid function, and clinical symptoms were evaluated before ablation. Contrast-enhanced ultrasound (CEUS) was performed 1 h after treatment to evaluate whether the ablation was complete. Ultrasound examination was performed at 1, 3, 6, and 12 months after ablation and every 6 months thereafter to determine the size of the ablation area and search for recurrence in the thyroid parenchyma and lymph node metastasis. Thyroid function was examined before and 1 month after ablation. Fine needle aspiration biopsy was performed for any suspicious metastatic lymph nodes and recurrent lesions in the thyroid. RESULTS: All 105 lesions were completely inactivated after one ablation, making the success rate for single ablation 100%. The average ablation time was 2.78 ± 1.05 min, and the average ablation energy was 505 ± 185 J. All patients could tolerate and complete the ablation. No serious complications occurred during the treatment; only minor side effects such as pain and local discomfort were reported. The volume reduction rates were −781.14 ± 653.29% at 1 h posttreatment and −268.65 ± 179.57%, −98.39 ± 76.58%, 36.78 ± 30.32%, 75.55 ± 21.81%, 96.79 ± 10.57%, and 100% at 1, 3, 6, 12, 18, and 24 months after ablation, respectively. This rate remained 100% at the later follow-up times. Overall, 28 (26.67%), 74 (70.48%), 96 (91.43%), and 103 (100%) were completely absorbed by 6, 12, 18, and 24 months after PLA. One patient developed another lesion 12 months after ablation, and two patients had central cervical lymph node metastasis 24 months after ablation. CONCLUSION: PLA is a safe and effective alternative clinical treatment for low-risk PTMC.
format Online
Article
Text
id pubmed-8324339
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-83243392021-07-31 Long-Term Efficacy of Ultrasound-Guided Percutaneous Laser Ablation for Low-Risk Papillary Thyroid Microcarcinoma: A 5-Year Follow-Up Study Peng, Kai Zhou, Ping Liu, Wengang Biomed Res Int Research Article OBJECTIVE: To evaluate the long-term efficacy and safety of ultrasound-guided percutaneous laser ablation (PLA) for the treatment of low-risk papillary thyroid microcarcinoma (PTMC). METHODS: From June 2012 to May 2015, 105 patients with solitary, pathologically confirmed PTMC lesions were treated with ultrasound-guided PLA. Nodule location, nodule volume, thyroid function, and clinical symptoms were evaluated before ablation. Contrast-enhanced ultrasound (CEUS) was performed 1 h after treatment to evaluate whether the ablation was complete. Ultrasound examination was performed at 1, 3, 6, and 12 months after ablation and every 6 months thereafter to determine the size of the ablation area and search for recurrence in the thyroid parenchyma and lymph node metastasis. Thyroid function was examined before and 1 month after ablation. Fine needle aspiration biopsy was performed for any suspicious metastatic lymph nodes and recurrent lesions in the thyroid. RESULTS: All 105 lesions were completely inactivated after one ablation, making the success rate for single ablation 100%. The average ablation time was 2.78 ± 1.05 min, and the average ablation energy was 505 ± 185 J. All patients could tolerate and complete the ablation. No serious complications occurred during the treatment; only minor side effects such as pain and local discomfort were reported. The volume reduction rates were −781.14 ± 653.29% at 1 h posttreatment and −268.65 ± 179.57%, −98.39 ± 76.58%, 36.78 ± 30.32%, 75.55 ± 21.81%, 96.79 ± 10.57%, and 100% at 1, 3, 6, 12, 18, and 24 months after ablation, respectively. This rate remained 100% at the later follow-up times. Overall, 28 (26.67%), 74 (70.48%), 96 (91.43%), and 103 (100%) were completely absorbed by 6, 12, 18, and 24 months after PLA. One patient developed another lesion 12 months after ablation, and two patients had central cervical lymph node metastasis 24 months after ablation. CONCLUSION: PLA is a safe and effective alternative clinical treatment for low-risk PTMC. Hindawi 2021-07-23 /pmc/articles/PMC8324339/ /pubmed/34337037 http://dx.doi.org/10.1155/2021/6616826 Text en Copyright © 2021 Kai Peng et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Peng, Kai
Zhou, Ping
Liu, Wengang
Long-Term Efficacy of Ultrasound-Guided Percutaneous Laser Ablation for Low-Risk Papillary Thyroid Microcarcinoma: A 5-Year Follow-Up Study
title Long-Term Efficacy of Ultrasound-Guided Percutaneous Laser Ablation for Low-Risk Papillary Thyroid Microcarcinoma: A 5-Year Follow-Up Study
title_full Long-Term Efficacy of Ultrasound-Guided Percutaneous Laser Ablation for Low-Risk Papillary Thyroid Microcarcinoma: A 5-Year Follow-Up Study
title_fullStr Long-Term Efficacy of Ultrasound-Guided Percutaneous Laser Ablation for Low-Risk Papillary Thyroid Microcarcinoma: A 5-Year Follow-Up Study
title_full_unstemmed Long-Term Efficacy of Ultrasound-Guided Percutaneous Laser Ablation for Low-Risk Papillary Thyroid Microcarcinoma: A 5-Year Follow-Up Study
title_short Long-Term Efficacy of Ultrasound-Guided Percutaneous Laser Ablation for Low-Risk Papillary Thyroid Microcarcinoma: A 5-Year Follow-Up Study
title_sort long-term efficacy of ultrasound-guided percutaneous laser ablation for low-risk papillary thyroid microcarcinoma: a 5-year follow-up study
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8324339/
https://www.ncbi.nlm.nih.gov/pubmed/34337037
http://dx.doi.org/10.1155/2021/6616826
work_keys_str_mv AT pengkai longtermefficacyofultrasoundguidedpercutaneouslaserablationforlowriskpapillarythyroidmicrocarcinomaa5yearfollowupstudy
AT zhouping longtermefficacyofultrasoundguidedpercutaneouslaserablationforlowriskpapillarythyroidmicrocarcinomaa5yearfollowupstudy
AT liuwengang longtermefficacyofultrasoundguidedpercutaneouslaserablationforlowriskpapillarythyroidmicrocarcinomaa5yearfollowupstudy