Cargando…

Enhanced interfragmentary stability and improved clinical prognosis with use of the off-axis screw technique to treat vertical femoral neck fractures in nongeriatric patients

BACKGROUND: The optimal internal fixation strategy for vertical femoral neck fractures (VFNFs) in nongeriatric patients remains uncertain. Therefore, the purpose of this study was to compare the clinical prognoses and underlying mechanical characteristics of a novel off-axis screw technique with dyn...

Descripción completa

Detalles Bibliográficos
Autores principales: Jiang, Dajun, Zhan, Shi, Cai, Qianying, Hu, Hai, Jia, Weitao
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8325251/
https://www.ncbi.nlm.nih.gov/pubmed/34332590
http://dx.doi.org/10.1186/s13018-021-02619-8
_version_ 1783731527789576192
author Jiang, Dajun
Zhan, Shi
Cai, Qianying
Hu, Hai
Jia, Weitao
author_facet Jiang, Dajun
Zhan, Shi
Cai, Qianying
Hu, Hai
Jia, Weitao
author_sort Jiang, Dajun
collection PubMed
description BACKGROUND: The optimal internal fixation strategy for vertical femoral neck fractures (VFNFs) in nongeriatric patients remains uncertain. Therefore, the purpose of this study was to compare the clinical prognoses and underlying mechanical characteristics of a novel off-axis screw technique with dynamic hip screws (DHSs) and three traditional parallel screws. METHODS: This study included a clinical investigation and a patient-specific finite element analysis (FEA). In the clinical investigation, VFNF patients were grouped by fixation type: (1) use of three parallel screws (G-TRI); (2) augmentation with an off-axis screw (G-ALP); and (3) DHS with an anti-rotational screw (G-DHS). Fixation failures (nonunion, femoral neck shortening (FNS), varus deformation, screw cut-out) and avascular necrosis (AVN) consequent to the three types of fixations were compared. In the FEA, twenty-four fixation models with the three fixation types were created based on the data of eight healthy volunteers. Models were assessed under walking conditions. Stiffness, interfragmentary motion (IFM), and implant stress were evaluated. RESULTS: In the clinical investigation, the fixation failure rate was significantly (p < 0.05) lower in G-ALP (18.5%) than in G-DHS (37.5%) and G-TRI (39.3%). No significant difference in AVN was observed among the three fixation groups. In the FEA, stiffness and implant stress in the G-DHS models were significantly (p < 0.05) higher, and the IFM of G-ALP was significantly (p < 0.05) lower among the groups. CONCLUSIONS: Among fixation types for VFNFs, the off-axis screw technique exhibited better interfragmentary stability (lowest IFM) and a lower fixation failure rate (especially FNS). Analyzing interfragmentary stability in biomechanical experiments is more consistent with clinical prognosis than construct stability for VFNFs, suggesting that internal fixations should aim for this outcome. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13018-021-02619-8.
format Online
Article
Text
id pubmed-8325251
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-83252512021-08-02 Enhanced interfragmentary stability and improved clinical prognosis with use of the off-axis screw technique to treat vertical femoral neck fractures in nongeriatric patients Jiang, Dajun Zhan, Shi Cai, Qianying Hu, Hai Jia, Weitao J Orthop Surg Res Research Article BACKGROUND: The optimal internal fixation strategy for vertical femoral neck fractures (VFNFs) in nongeriatric patients remains uncertain. Therefore, the purpose of this study was to compare the clinical prognoses and underlying mechanical characteristics of a novel off-axis screw technique with dynamic hip screws (DHSs) and three traditional parallel screws. METHODS: This study included a clinical investigation and a patient-specific finite element analysis (FEA). In the clinical investigation, VFNF patients were grouped by fixation type: (1) use of three parallel screws (G-TRI); (2) augmentation with an off-axis screw (G-ALP); and (3) DHS with an anti-rotational screw (G-DHS). Fixation failures (nonunion, femoral neck shortening (FNS), varus deformation, screw cut-out) and avascular necrosis (AVN) consequent to the three types of fixations were compared. In the FEA, twenty-four fixation models with the three fixation types were created based on the data of eight healthy volunteers. Models were assessed under walking conditions. Stiffness, interfragmentary motion (IFM), and implant stress were evaluated. RESULTS: In the clinical investigation, the fixation failure rate was significantly (p < 0.05) lower in G-ALP (18.5%) than in G-DHS (37.5%) and G-TRI (39.3%). No significant difference in AVN was observed among the three fixation groups. In the FEA, stiffness and implant stress in the G-DHS models were significantly (p < 0.05) higher, and the IFM of G-ALP was significantly (p < 0.05) lower among the groups. CONCLUSIONS: Among fixation types for VFNFs, the off-axis screw technique exhibited better interfragmentary stability (lowest IFM) and a lower fixation failure rate (especially FNS). Analyzing interfragmentary stability in biomechanical experiments is more consistent with clinical prognosis than construct stability for VFNFs, suggesting that internal fixations should aim for this outcome. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s13018-021-02619-8. BioMed Central 2021-07-31 /pmc/articles/PMC8325251/ /pubmed/34332590 http://dx.doi.org/10.1186/s13018-021-02619-8 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research Article
Jiang, Dajun
Zhan, Shi
Cai, Qianying
Hu, Hai
Jia, Weitao
Enhanced interfragmentary stability and improved clinical prognosis with use of the off-axis screw technique to treat vertical femoral neck fractures in nongeriatric patients
title Enhanced interfragmentary stability and improved clinical prognosis with use of the off-axis screw technique to treat vertical femoral neck fractures in nongeriatric patients
title_full Enhanced interfragmentary stability and improved clinical prognosis with use of the off-axis screw technique to treat vertical femoral neck fractures in nongeriatric patients
title_fullStr Enhanced interfragmentary stability and improved clinical prognosis with use of the off-axis screw technique to treat vertical femoral neck fractures in nongeriatric patients
title_full_unstemmed Enhanced interfragmentary stability and improved clinical prognosis with use of the off-axis screw technique to treat vertical femoral neck fractures in nongeriatric patients
title_short Enhanced interfragmentary stability and improved clinical prognosis with use of the off-axis screw technique to treat vertical femoral neck fractures in nongeriatric patients
title_sort enhanced interfragmentary stability and improved clinical prognosis with use of the off-axis screw technique to treat vertical femoral neck fractures in nongeriatric patients
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8325251/
https://www.ncbi.nlm.nih.gov/pubmed/34332590
http://dx.doi.org/10.1186/s13018-021-02619-8
work_keys_str_mv AT jiangdajun enhancedinterfragmentarystabilityandimprovedclinicalprognosiswithuseoftheoffaxisscrewtechniquetotreatverticalfemoralneckfracturesinnongeriatricpatients
AT zhanshi enhancedinterfragmentarystabilityandimprovedclinicalprognosiswithuseoftheoffaxisscrewtechniquetotreatverticalfemoralneckfracturesinnongeriatricpatients
AT caiqianying enhancedinterfragmentarystabilityandimprovedclinicalprognosiswithuseoftheoffaxisscrewtechniquetotreatverticalfemoralneckfracturesinnongeriatricpatients
AT huhai enhancedinterfragmentarystabilityandimprovedclinicalprognosiswithuseoftheoffaxisscrewtechniquetotreatverticalfemoralneckfracturesinnongeriatricpatients
AT jiaweitao enhancedinterfragmentarystabilityandimprovedclinicalprognosiswithuseoftheoffaxisscrewtechniquetotreatverticalfemoralneckfracturesinnongeriatricpatients