The use of X-ray microtomography to investigate the microstructure of pharmaceutical tablets: Potentials and comparison to common physical methods

Within this study, tablets microstructure was investigated by X-ray microtomgraphy. The aim was to gain information about their microstructure, and thus, derive deeper interpretation of tablet properties (mechanical strength, component distribution) and qualified property functions. Challenges in im...

Descripción completa

Detalles Bibliográficos
Autores principales: Schomberg, Ann Kathrin, Diener, Alexander, Wünsch, Isabell, Finke, Jan Henrik, Kwade, Arno
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8327351/
https://www.ncbi.nlm.nih.gov/pubmed/34377974
http://dx.doi.org/10.1016/j.ijpx.2021.100090
_version_ 1783732057636077568
author Schomberg, Ann Kathrin
Diener, Alexander
Wünsch, Isabell
Finke, Jan Henrik
Kwade, Arno
author_facet Schomberg, Ann Kathrin
Diener, Alexander
Wünsch, Isabell
Finke, Jan Henrik
Kwade, Arno
author_sort Schomberg, Ann Kathrin
collection PubMed
description Within this study, tablets microstructure was investigated by X-ray microtomgraphy. The aim was to gain information about their microstructure, and thus, derive deeper interpretation of tablet properties (mechanical strength, component distribution) and qualified property functions. Challenges in image processing are discussed for the correct identification of solids and voids. Furthermore, XMT measurements are critically compared with complementary physical methods for characterizing active pharmaceutical ingredient (API) content and porosity and its distribution (mercury porosimetry, calculated tablet porosity, Focused Ion Beam-Scanning Electron Microscopy (FIB-SEM)). The derived porosity by XMT is generally lower than the calculated porosity based on geometrical data due to the resolution of the XMT in relation to the pore sizes in tablets. With rising compactions stress and API concentration, deviations between the actual and the calculated API decrease. XMT showed that API clusters are present for all tablets containing >1 wt% of ibuprofen. The 3D orientation of the components is assessable by deriving cord lengths along all dimensions of the tablets. An increasing compaction stress leads to rising cord lengths, showing higher connectivity of the respective material. Its lesser extent in the z-direction illustrates the anisotropy of the compaction process. Additionally, cracks in the fabric are identified in tablets without visible macroscopic damage. Finally, the application of XMT provides valuable structural insights if its limitations are taken into account and its strengths are fostered by advanced pre- and post-processing.
format Online
Article
Text
id pubmed-8327351
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-83273512021-08-09 The use of X-ray microtomography to investigate the microstructure of pharmaceutical tablets: Potentials and comparison to common physical methods Schomberg, Ann Kathrin Diener, Alexander Wünsch, Isabell Finke, Jan Henrik Kwade, Arno Int J Pharm X Research Paper Within this study, tablets microstructure was investigated by X-ray microtomgraphy. The aim was to gain information about their microstructure, and thus, derive deeper interpretation of tablet properties (mechanical strength, component distribution) and qualified property functions. Challenges in image processing are discussed for the correct identification of solids and voids. Furthermore, XMT measurements are critically compared with complementary physical methods for characterizing active pharmaceutical ingredient (API) content and porosity and its distribution (mercury porosimetry, calculated tablet porosity, Focused Ion Beam-Scanning Electron Microscopy (FIB-SEM)). The derived porosity by XMT is generally lower than the calculated porosity based on geometrical data due to the resolution of the XMT in relation to the pore sizes in tablets. With rising compactions stress and API concentration, deviations between the actual and the calculated API decrease. XMT showed that API clusters are present for all tablets containing >1 wt% of ibuprofen. The 3D orientation of the components is assessable by deriving cord lengths along all dimensions of the tablets. An increasing compaction stress leads to rising cord lengths, showing higher connectivity of the respective material. Its lesser extent in the z-direction illustrates the anisotropy of the compaction process. Additionally, cracks in the fabric are identified in tablets without visible macroscopic damage. Finally, the application of XMT provides valuable structural insights if its limitations are taken into account and its strengths are fostered by advanced pre- and post-processing. Elsevier 2021-07-10 /pmc/articles/PMC8327351/ /pubmed/34377974 http://dx.doi.org/10.1016/j.ijpx.2021.100090 Text en © 2021 The Author(s) https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Research Paper
Schomberg, Ann Kathrin
Diener, Alexander
Wünsch, Isabell
Finke, Jan Henrik
Kwade, Arno
The use of X-ray microtomography to investigate the microstructure of pharmaceutical tablets: Potentials and comparison to common physical methods
title The use of X-ray microtomography to investigate the microstructure of pharmaceutical tablets: Potentials and comparison to common physical methods
title_full The use of X-ray microtomography to investigate the microstructure of pharmaceutical tablets: Potentials and comparison to common physical methods
title_fullStr The use of X-ray microtomography to investigate the microstructure of pharmaceutical tablets: Potentials and comparison to common physical methods
title_full_unstemmed The use of X-ray microtomography to investigate the microstructure of pharmaceutical tablets: Potentials and comparison to common physical methods
title_short The use of X-ray microtomography to investigate the microstructure of pharmaceutical tablets: Potentials and comparison to common physical methods
title_sort use of x-ray microtomography to investigate the microstructure of pharmaceutical tablets: potentials and comparison to common physical methods
topic Research Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8327351/
https://www.ncbi.nlm.nih.gov/pubmed/34377974
http://dx.doi.org/10.1016/j.ijpx.2021.100090
work_keys_str_mv AT schombergannkathrin theuseofxraymicrotomographytoinvestigatethemicrostructureofpharmaceuticaltabletspotentialsandcomparisontocommonphysicalmethods
AT dieneralexander theuseofxraymicrotomographytoinvestigatethemicrostructureofpharmaceuticaltabletspotentialsandcomparisontocommonphysicalmethods
AT wunschisabell theuseofxraymicrotomographytoinvestigatethemicrostructureofpharmaceuticaltabletspotentialsandcomparisontocommonphysicalmethods
AT finkejanhenrik theuseofxraymicrotomographytoinvestigatethemicrostructureofpharmaceuticaltabletspotentialsandcomparisontocommonphysicalmethods
AT kwadearno theuseofxraymicrotomographytoinvestigatethemicrostructureofpharmaceuticaltabletspotentialsandcomparisontocommonphysicalmethods
AT schombergannkathrin useofxraymicrotomographytoinvestigatethemicrostructureofpharmaceuticaltabletspotentialsandcomparisontocommonphysicalmethods
AT dieneralexander useofxraymicrotomographytoinvestigatethemicrostructureofpharmaceuticaltabletspotentialsandcomparisontocommonphysicalmethods
AT wunschisabell useofxraymicrotomographytoinvestigatethemicrostructureofpharmaceuticaltabletspotentialsandcomparisontocommonphysicalmethods
AT finkejanhenrik useofxraymicrotomographytoinvestigatethemicrostructureofpharmaceuticaltabletspotentialsandcomparisontocommonphysicalmethods
AT kwadearno useofxraymicrotomographytoinvestigatethemicrostructureofpharmaceuticaltabletspotentialsandcomparisontocommonphysicalmethods