Cargando…
Fully automated whole-liver volume quantification on CT-image data: Comparison with manual volumetry using enhanced and unenhanced images as well as two different radiation dose levels and two reconstruction kernels
OBJECTIVES: To evaluate the accuracy of fully automated liver volume quantification vs. manual quantification using unenhanced as well as enhanced CT-image data as well as two different radiation dose levels and also two image reconstruction kernels. MATERIAL AND METHODS: The local ethics board gave...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Public Library of Science
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8328340/ https://www.ncbi.nlm.nih.gov/pubmed/34339472 http://dx.doi.org/10.1371/journal.pone.0255374 |
_version_ | 1783732290296217600 |
---|---|
author | Hagen, Florian Mair, Antonia Bitzer, Michael Bösmüller, Hans Horger, Marius |
author_facet | Hagen, Florian Mair, Antonia Bitzer, Michael Bösmüller, Hans Horger, Marius |
author_sort | Hagen, Florian |
collection | PubMed |
description | OBJECTIVES: To evaluate the accuracy of fully automated liver volume quantification vs. manual quantification using unenhanced as well as enhanced CT-image data as well as two different radiation dose levels and also two image reconstruction kernels. MATERIAL AND METHODS: The local ethics board gave its approval for retrospective data analysis. Automated liver volume quantification in 300 consecutive livers in 164 male and 103 female oncologic patients (64±12y) performed at our institution (between January 2020 and May 2020) using two different dual-energy helicals: portal-venous phase enhanced, ref. tube current 300mAs (CARE Dose4D) for tube A (100 kV) and ref. 232mAs tube current for tube B (Sn140kV), slice collimation 0.6mm, reconstruction kernel I30f/1, recon. thickness of 0.6mm and 5mm, 80–100 mL iodine contrast agent 350 mg/mL, (flow 2mL/s) and unenhanced ref. tube current 100mAs (CARE Dose4D) for tube A (100 kV) and ref. 77mAs tube current for tube B (Sn140kV), slice collimation 0.6mm (kernel Q40f) were analyzed. The post-processing tool (syngo.CT Liver Analysis) is already FDA-approved. Two resident radiologists with no and 1-year CT-experience performed both the automated measurements independently from each other. Results were compared with those of manual liver volume quantification using the same software which was supervised by a senior radiologist with 30-year CT-experience (ground truth). RESULTS: In total, a correlation of 98% was obtained for liver volumetry based on enhanced and unenhanced data sets compared to the manual liver quantification. Radiologist #1 and #2 achieved an inter-reader agreement of 99.8% for manual liver segmentation (p<0.0001). Automated liver volumetry resulted in an overestimation (>5% deviation) of 3.7% for unenhanced CT-image data and 4.0% for contrast-enhanced CT-images. Underestimation (<5%) of liver volume was 2.0% for unenhanced CT-image data and 1.3% for enhanced images after automated liver volumetry. Number and distribution of erroneous volume measurements using either thin or thick slice reconstructions was exactly the same, both for the enhanced as well for the unenhanced image data sets (p> 0.05). CONCLUSION: Results of fully automated liver volume quantification are accurate and comparable with those of manual liver volume quantification and the technique seems to be confident even if unenhanced lower-dose CT image data is used. |
format | Online Article Text |
id | pubmed-8328340 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Public Library of Science |
record_format | MEDLINE/PubMed |
spelling | pubmed-83283402021-08-03 Fully automated whole-liver volume quantification on CT-image data: Comparison with manual volumetry using enhanced and unenhanced images as well as two different radiation dose levels and two reconstruction kernels Hagen, Florian Mair, Antonia Bitzer, Michael Bösmüller, Hans Horger, Marius PLoS One Research Article OBJECTIVES: To evaluate the accuracy of fully automated liver volume quantification vs. manual quantification using unenhanced as well as enhanced CT-image data as well as two different radiation dose levels and also two image reconstruction kernels. MATERIAL AND METHODS: The local ethics board gave its approval for retrospective data analysis. Automated liver volume quantification in 300 consecutive livers in 164 male and 103 female oncologic patients (64±12y) performed at our institution (between January 2020 and May 2020) using two different dual-energy helicals: portal-venous phase enhanced, ref. tube current 300mAs (CARE Dose4D) for tube A (100 kV) and ref. 232mAs tube current for tube B (Sn140kV), slice collimation 0.6mm, reconstruction kernel I30f/1, recon. thickness of 0.6mm and 5mm, 80–100 mL iodine contrast agent 350 mg/mL, (flow 2mL/s) and unenhanced ref. tube current 100mAs (CARE Dose4D) for tube A (100 kV) and ref. 77mAs tube current for tube B (Sn140kV), slice collimation 0.6mm (kernel Q40f) were analyzed. The post-processing tool (syngo.CT Liver Analysis) is already FDA-approved. Two resident radiologists with no and 1-year CT-experience performed both the automated measurements independently from each other. Results were compared with those of manual liver volume quantification using the same software which was supervised by a senior radiologist with 30-year CT-experience (ground truth). RESULTS: In total, a correlation of 98% was obtained for liver volumetry based on enhanced and unenhanced data sets compared to the manual liver quantification. Radiologist #1 and #2 achieved an inter-reader agreement of 99.8% for manual liver segmentation (p<0.0001). Automated liver volumetry resulted in an overestimation (>5% deviation) of 3.7% for unenhanced CT-image data and 4.0% for contrast-enhanced CT-images. Underestimation (<5%) of liver volume was 2.0% for unenhanced CT-image data and 1.3% for enhanced images after automated liver volumetry. Number and distribution of erroneous volume measurements using either thin or thick slice reconstructions was exactly the same, both for the enhanced as well for the unenhanced image data sets (p> 0.05). CONCLUSION: Results of fully automated liver volume quantification are accurate and comparable with those of manual liver volume quantification and the technique seems to be confident even if unenhanced lower-dose CT image data is used. Public Library of Science 2021-08-02 /pmc/articles/PMC8328340/ /pubmed/34339472 http://dx.doi.org/10.1371/journal.pone.0255374 Text en © 2021 Hagen et al https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/) , which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited. |
spellingShingle | Research Article Hagen, Florian Mair, Antonia Bitzer, Michael Bösmüller, Hans Horger, Marius Fully automated whole-liver volume quantification on CT-image data: Comparison with manual volumetry using enhanced and unenhanced images as well as two different radiation dose levels and two reconstruction kernels |
title | Fully automated whole-liver volume quantification on CT-image data: Comparison with manual volumetry using enhanced and unenhanced images as well as two different radiation dose levels and two reconstruction kernels |
title_full | Fully automated whole-liver volume quantification on CT-image data: Comparison with manual volumetry using enhanced and unenhanced images as well as two different radiation dose levels and two reconstruction kernels |
title_fullStr | Fully automated whole-liver volume quantification on CT-image data: Comparison with manual volumetry using enhanced and unenhanced images as well as two different radiation dose levels and two reconstruction kernels |
title_full_unstemmed | Fully automated whole-liver volume quantification on CT-image data: Comparison with manual volumetry using enhanced and unenhanced images as well as two different radiation dose levels and two reconstruction kernels |
title_short | Fully automated whole-liver volume quantification on CT-image data: Comparison with manual volumetry using enhanced and unenhanced images as well as two different radiation dose levels and two reconstruction kernels |
title_sort | fully automated whole-liver volume quantification on ct-image data: comparison with manual volumetry using enhanced and unenhanced images as well as two different radiation dose levels and two reconstruction kernels |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8328340/ https://www.ncbi.nlm.nih.gov/pubmed/34339472 http://dx.doi.org/10.1371/journal.pone.0255374 |
work_keys_str_mv | AT hagenflorian fullyautomatedwholelivervolumequantificationonctimagedatacomparisonwithmanualvolumetryusingenhancedandunenhancedimagesaswellastwodifferentradiationdoselevelsandtworeconstructionkernels AT mairantonia fullyautomatedwholelivervolumequantificationonctimagedatacomparisonwithmanualvolumetryusingenhancedandunenhancedimagesaswellastwodifferentradiationdoselevelsandtworeconstructionkernels AT bitzermichael fullyautomatedwholelivervolumequantificationonctimagedatacomparisonwithmanualvolumetryusingenhancedandunenhancedimagesaswellastwodifferentradiationdoselevelsandtworeconstructionkernels AT bosmullerhans fullyautomatedwholelivervolumequantificationonctimagedatacomparisonwithmanualvolumetryusingenhancedandunenhancedimagesaswellastwodifferentradiationdoselevelsandtworeconstructionkernels AT horgermarius fullyautomatedwholelivervolumequantificationonctimagedatacomparisonwithmanualvolumetryusingenhancedandunenhancedimagesaswellastwodifferentradiationdoselevelsandtworeconstructionkernels |