Cargando…

Case Report: Trans-Articular External Skeletal Fixation of the Hip for a Highly Comminuted Juxta-Articular Fracture of the Proximal Femur Caused by Gunshot Injury in a Cat

This report describes a novel surgical technique for trans-articular external skeletal fixation (TA-ESF) of the hip to stabilize a rare, highly comminuted juxta-articular fracture of the proximal femoral segment involving the metaphysis and diaphysis in a cat. A 2-year-old, castrated male, Korean sh...

Descripción completa

Detalles Bibliográficos
Autores principales: Han, Hyun-Jung, Lee, Kyeongpung, Yoon, Hun-Young
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8328486/
https://www.ncbi.nlm.nih.gov/pubmed/34350224
http://dx.doi.org/10.3389/fvets.2021.652847
_version_ 1783732328621670400
author Han, Hyun-Jung
Lee, Kyeongpung
Yoon, Hun-Young
author_facet Han, Hyun-Jung
Lee, Kyeongpung
Yoon, Hun-Young
author_sort Han, Hyun-Jung
collection PubMed
description This report describes a novel surgical technique for trans-articular external skeletal fixation (TA-ESF) of the hip to stabilize a rare, highly comminuted juxta-articular fracture of the proximal femoral segment involving the metaphysis and diaphysis in a cat. A 2-year-old, castrated male, Korean shorthair cat was admitted for a left femoral fracture caused by gunshot injury. Radiographs and computed tomography (CT) scans revealed a highly comminuted proximal femoral diaphyseal fracture that involved the femoral neck and the greater trochanter. The left femoral head was intact on CT. Under fluoroscopic guidance, an intramedullary Steinmann pin was placed to align the femur, and five positive-profile, end-threaded pins were placed in the left hemipelvis and distal femur. A triangulated frame of connecting bars was constructed using Steinmann pins and epoxy resin for TA-ESF. This secured the pins placed in the pelvis and femur as well as the intramedullary pin, providing proximal femoral stabilization by trans-articular fixation of the hip. The cat began placing weight on the left pelvic limb 4 days postoperatively, and progressively obtained near-normal limb function by day 112. The TA-ESF was partially dismantled to a linear tie-in construct on day 64 and was completely removed on day 161. Final radiographs on day 161 revealed lack of bone healing in the proximal segment, especially femoral head and neck, despite functional recovery of the injured leg. At one year postoperatively, the cat had normal limb function without any noticeable complications. On follow-up 29 months after surgery, the owner reported that the cat had normal limb function without any noticeable complications. Despite insufficient bone healing in the cat, TA-ESF of the hip allowed for satisfactory functional recovery of this challenging juxta-articular fracture of the proximal femur, which was not amenable to stabilization with a traditional non-load-sharing fixation system.
format Online
Article
Text
id pubmed-8328486
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-83284862021-08-03 Case Report: Trans-Articular External Skeletal Fixation of the Hip for a Highly Comminuted Juxta-Articular Fracture of the Proximal Femur Caused by Gunshot Injury in a Cat Han, Hyun-Jung Lee, Kyeongpung Yoon, Hun-Young Front Vet Sci Veterinary Science This report describes a novel surgical technique for trans-articular external skeletal fixation (TA-ESF) of the hip to stabilize a rare, highly comminuted juxta-articular fracture of the proximal femoral segment involving the metaphysis and diaphysis in a cat. A 2-year-old, castrated male, Korean shorthair cat was admitted for a left femoral fracture caused by gunshot injury. Radiographs and computed tomography (CT) scans revealed a highly comminuted proximal femoral diaphyseal fracture that involved the femoral neck and the greater trochanter. The left femoral head was intact on CT. Under fluoroscopic guidance, an intramedullary Steinmann pin was placed to align the femur, and five positive-profile, end-threaded pins were placed in the left hemipelvis and distal femur. A triangulated frame of connecting bars was constructed using Steinmann pins and epoxy resin for TA-ESF. This secured the pins placed in the pelvis and femur as well as the intramedullary pin, providing proximal femoral stabilization by trans-articular fixation of the hip. The cat began placing weight on the left pelvic limb 4 days postoperatively, and progressively obtained near-normal limb function by day 112. The TA-ESF was partially dismantled to a linear tie-in construct on day 64 and was completely removed on day 161. Final radiographs on day 161 revealed lack of bone healing in the proximal segment, especially femoral head and neck, despite functional recovery of the injured leg. At one year postoperatively, the cat had normal limb function without any noticeable complications. On follow-up 29 months after surgery, the owner reported that the cat had normal limb function without any noticeable complications. Despite insufficient bone healing in the cat, TA-ESF of the hip allowed for satisfactory functional recovery of this challenging juxta-articular fracture of the proximal femur, which was not amenable to stabilization with a traditional non-load-sharing fixation system. Frontiers Media S.A. 2021-07-19 /pmc/articles/PMC8328486/ /pubmed/34350224 http://dx.doi.org/10.3389/fvets.2021.652847 Text en Copyright © 2021 Han, Lee and Yoon. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Veterinary Science
Han, Hyun-Jung
Lee, Kyeongpung
Yoon, Hun-Young
Case Report: Trans-Articular External Skeletal Fixation of the Hip for a Highly Comminuted Juxta-Articular Fracture of the Proximal Femur Caused by Gunshot Injury in a Cat
title Case Report: Trans-Articular External Skeletal Fixation of the Hip for a Highly Comminuted Juxta-Articular Fracture of the Proximal Femur Caused by Gunshot Injury in a Cat
title_full Case Report: Trans-Articular External Skeletal Fixation of the Hip for a Highly Comminuted Juxta-Articular Fracture of the Proximal Femur Caused by Gunshot Injury in a Cat
title_fullStr Case Report: Trans-Articular External Skeletal Fixation of the Hip for a Highly Comminuted Juxta-Articular Fracture of the Proximal Femur Caused by Gunshot Injury in a Cat
title_full_unstemmed Case Report: Trans-Articular External Skeletal Fixation of the Hip for a Highly Comminuted Juxta-Articular Fracture of the Proximal Femur Caused by Gunshot Injury in a Cat
title_short Case Report: Trans-Articular External Skeletal Fixation of the Hip for a Highly Comminuted Juxta-Articular Fracture of the Proximal Femur Caused by Gunshot Injury in a Cat
title_sort case report: trans-articular external skeletal fixation of the hip for a highly comminuted juxta-articular fracture of the proximal femur caused by gunshot injury in a cat
topic Veterinary Science
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8328486/
https://www.ncbi.nlm.nih.gov/pubmed/34350224
http://dx.doi.org/10.3389/fvets.2021.652847
work_keys_str_mv AT hanhyunjung casereporttransarticularexternalskeletalfixationofthehipforahighlycomminutedjuxtaarticularfractureoftheproximalfemurcausedbygunshotinjuryinacat
AT leekyeongpung casereporttransarticularexternalskeletalfixationofthehipforahighlycomminutedjuxtaarticularfractureoftheproximalfemurcausedbygunshotinjuryinacat
AT yoonhunyoung casereporttransarticularexternalskeletalfixationofthehipforahighlycomminutedjuxtaarticularfractureoftheproximalfemurcausedbygunshotinjuryinacat