Accuracy of the SWAY Mobile Cognitive Assessment Application
BACKGROUND: Mobile electronic devices have become integral tools in addressing the need for portable assessment of cognitive function following neurocognitive/motor injury. SWAY Medical, Inc., has employed mobile device motion-based technology in the SWAY Cognitive Assessment (SWAY CA) application t...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
NASMI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8329324/ https://www.ncbi.nlm.nih.gov/pubmed/34386278 http://dx.doi.org/10.26603/001c.24924 |
_version_ | 1783732474808893440 |
---|---|
author | VanRavenhorst-Bell, Heidi A. Muzeau, Melissa A. Luinstra, Lindsay Goering, Jared Amick, Ryan Z. |
author_facet | VanRavenhorst-Bell, Heidi A. Muzeau, Melissa A. Luinstra, Lindsay Goering, Jared Amick, Ryan Z. |
author_sort | VanRavenhorst-Bell, Heidi A. |
collection | PubMed |
description | BACKGROUND: Mobile electronic devices have become integral tools in addressing the need for portable assessment of cognitive function following neurocognitive/motor injury. SWAY Medical, Inc., has employed mobile device motion-based technology in the SWAY Cognitive Assessment (SWAY CA) application to assess cognitive function. PURPOSE: The purpose of this study was to assess whether the SWAY CA application (reaction time, impulse control and inspective time) was able to reliably operate on different mobile devices and operating systems (iOS, Android). The study further sought to assess the validity of the SWAY CA application against the FDA approved ImPACT QT mobile device application. STUDY DESIGN: Original Research, observational study of validity. METHODS: 88 healthy, young adults, 18 to 48 years (mean= 22.09 ± sd=4.47 years) completed four, randomized and counter-balanced, reaction time tests (2- SWAY RT, 2- ImPACT QT) using different operating systems (iOS, Android) of 4 randomly assigned mobile devices. RESULTS: ANOVAs reported the SWAY CA application (reaction time, impulse control, inspection time) operated reliably with iPhone 6S, Samsung Galaxy S9, and iPad Pro 5 mobile devices (p > 0.05), respectively. Google Pixel 3 reliability with SWAY CA application remains undetermined. SWAY CA simple reaction motion measures were in agreement (r = -0.46 to 0.22, p ≤ 0.05) with several ImPACT QT reaction time measures. SWAY CA impulse control and inspection time measures are weakly correlated (r = -0.25 to -0.46, p ≤ 0.05) with five ImPACT QT reaction time measures. CONCLUSION: The motion-based SWAY CA mobile device application appears to reliably operate when being administered on different mobile devices and software operating systems. Furthermore, the SWAY CA application appears to be comparable to the ImPACT QT and serve as a valid tool for assessing reaction time measures. LEVEL OF EVIDENCE: Level 2b (observational study of validity). |
format | Online Article Text |
id | pubmed-8329324 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | NASMI |
record_format | MEDLINE/PubMed |
spelling | pubmed-83293242021-08-11 Accuracy of the SWAY Mobile Cognitive Assessment Application VanRavenhorst-Bell, Heidi A. Muzeau, Melissa A. Luinstra, Lindsay Goering, Jared Amick, Ryan Z. Int J Sports Phys Ther Original Research BACKGROUND: Mobile electronic devices have become integral tools in addressing the need for portable assessment of cognitive function following neurocognitive/motor injury. SWAY Medical, Inc., has employed mobile device motion-based technology in the SWAY Cognitive Assessment (SWAY CA) application to assess cognitive function. PURPOSE: The purpose of this study was to assess whether the SWAY CA application (reaction time, impulse control and inspective time) was able to reliably operate on different mobile devices and operating systems (iOS, Android). The study further sought to assess the validity of the SWAY CA application against the FDA approved ImPACT QT mobile device application. STUDY DESIGN: Original Research, observational study of validity. METHODS: 88 healthy, young adults, 18 to 48 years (mean= 22.09 ± sd=4.47 years) completed four, randomized and counter-balanced, reaction time tests (2- SWAY RT, 2- ImPACT QT) using different operating systems (iOS, Android) of 4 randomly assigned mobile devices. RESULTS: ANOVAs reported the SWAY CA application (reaction time, impulse control, inspection time) operated reliably with iPhone 6S, Samsung Galaxy S9, and iPad Pro 5 mobile devices (p > 0.05), respectively. Google Pixel 3 reliability with SWAY CA application remains undetermined. SWAY CA simple reaction motion measures were in agreement (r = -0.46 to 0.22, p ≤ 0.05) with several ImPACT QT reaction time measures. SWAY CA impulse control and inspection time measures are weakly correlated (r = -0.25 to -0.46, p ≤ 0.05) with five ImPACT QT reaction time measures. CONCLUSION: The motion-based SWAY CA mobile device application appears to reliably operate when being administered on different mobile devices and software operating systems. Furthermore, the SWAY CA application appears to be comparable to the ImPACT QT and serve as a valid tool for assessing reaction time measures. LEVEL OF EVIDENCE: Level 2b (observational study of validity). NASMI 2021-08-01 /pmc/articles/PMC8329324/ /pubmed/34386278 http://dx.doi.org/10.26603/001c.24924 Text en https://creativecommons.org/licenses/by-nc-sa/4.0/ This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike License (4.0) (https://creativecommons.org/licenses/by-nc-sa/4.0/) which permits non-commercial use, distribution, and reproduction in any medium, provided the original author and source are credited. If you remix, transform, or build upon this work, you must distribute your contributions under the same license as the original. |
spellingShingle | Original Research VanRavenhorst-Bell, Heidi A. Muzeau, Melissa A. Luinstra, Lindsay Goering, Jared Amick, Ryan Z. Accuracy of the SWAY Mobile Cognitive Assessment Application |
title | Accuracy of the SWAY Mobile Cognitive Assessment Application |
title_full | Accuracy of the SWAY Mobile Cognitive Assessment Application |
title_fullStr | Accuracy of the SWAY Mobile Cognitive Assessment Application |
title_full_unstemmed | Accuracy of the SWAY Mobile Cognitive Assessment Application |
title_short | Accuracy of the SWAY Mobile Cognitive Assessment Application |
title_sort | accuracy of the sway mobile cognitive assessment application |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8329324/ https://www.ncbi.nlm.nih.gov/pubmed/34386278 http://dx.doi.org/10.26603/001c.24924 |
work_keys_str_mv | AT vanravenhorstbellheidia accuracyoftheswaymobilecognitiveassessmentapplication AT muzeaumelissaa accuracyoftheswaymobilecognitiveassessmentapplication AT luinstralindsay accuracyoftheswaymobilecognitiveassessmentapplication AT goeringjared accuracyoftheswaymobilecognitiveassessmentapplication AT amickryanz accuracyoftheswaymobilecognitiveassessmentapplication |