Cargando…
Comparison of the optical quality after SMILE and FS-LASIK for high myopia by OQAS and iTrace analyzer: a one-year retrospective study
BACKGROUND: To compare the correction effect and optical quality after small-incision lenticule extraction (SMILE) and femtosecond laser assisted laser in situ keratomileusis (FS-LASIK) for high myopia. METHODS: 51 high myopia eyes after SMILE and 49 high myopia eyes after FS-LASIK were enrolled and...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8330115/ https://www.ncbi.nlm.nih.gov/pubmed/34340669 http://dx.doi.org/10.1186/s12886-021-02048-5 |
_version_ | 1783732634285768704 |
---|---|
author | Yin, Yewei Lu, Ying Xiang, Aiqun Fu, Yanyan Zhao, Yang Li, Yuanjun Hu, Tu Du, Kaixuan Hu, Shengfa Fu, Qiuman Wu, Xiaoying Wen, Dan |
author_facet | Yin, Yewei Lu, Ying Xiang, Aiqun Fu, Yanyan Zhao, Yang Li, Yuanjun Hu, Tu Du, Kaixuan Hu, Shengfa Fu, Qiuman Wu, Xiaoying Wen, Dan |
author_sort | Yin, Yewei |
collection | PubMed |
description | BACKGROUND: To compare the correction effect and optical quality after small-incision lenticule extraction (SMILE) and femtosecond laser assisted laser in situ keratomileusis (FS-LASIK) for high myopia. METHODS: 51 high myopia eyes after SMILE and 49 high myopia eyes after FS-LASIK were enrolled and divided into two groups retrospectively. The OQAS and iTrace analyzer were used for optical quality inspection. Between the two groups the spherical equivalent (SE), astigmatism, uncorrected distant visual acuity (UDVA), strehl ratio (SR), modulation transfer function cutoff frequency (MTF cutoff), objective scatter index (OSI) and wavefront aberrations were analyzed and compared before surgery and at 1, 6 and 12 months after surgery. RESULTS: After the operation: (1) SE and astigmatism declined and UDVA increased significantly in both groups, and UDVA was better after SMILE than FS-LASIK. (2) SR and MTF cutoff reduced and OSI increased significantly after SMILE and FS-LASIK. SR and MTF cutoff were significantly higher after SMILE than FS-LASIK. OSI was significantly lower after SMILE than FS-LASIK. (3) The total wavefront aberration, total low-order wavefront aberration, defocus and astigmatism aberration as well as trefoil aberration reduced significantly in both groups. The total high-order wavefront aberration increased significantly after FS-LASIK. The spherical and coma aberration increased significantly in both groups. The total high-order wavefront aberration and coma aberration at 1 month were higher after FS-LASIK than SMILE. CONCLUSION: The optical quality descended after SMILE and FS-LASIK. SMILE was superior to FS-LASIK at the correction effect and optical quality for high myopia. The combination of OQAS and iTrace analyzer is a valuable complementary measurement in evaluating the optical quality after the refractive surgery. TRIAL REGISTRATION: This is a retrospective study. This research was approved by the ethics committee of Xiangya Hospital and the IRB approval number is 201612074. |
format | Online Article Text |
id | pubmed-8330115 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-83301152021-08-04 Comparison of the optical quality after SMILE and FS-LASIK for high myopia by OQAS and iTrace analyzer: a one-year retrospective study Yin, Yewei Lu, Ying Xiang, Aiqun Fu, Yanyan Zhao, Yang Li, Yuanjun Hu, Tu Du, Kaixuan Hu, Shengfa Fu, Qiuman Wu, Xiaoying Wen, Dan BMC Ophthalmol Research BACKGROUND: To compare the correction effect and optical quality after small-incision lenticule extraction (SMILE) and femtosecond laser assisted laser in situ keratomileusis (FS-LASIK) for high myopia. METHODS: 51 high myopia eyes after SMILE and 49 high myopia eyes after FS-LASIK were enrolled and divided into two groups retrospectively. The OQAS and iTrace analyzer were used for optical quality inspection. Between the two groups the spherical equivalent (SE), astigmatism, uncorrected distant visual acuity (UDVA), strehl ratio (SR), modulation transfer function cutoff frequency (MTF cutoff), objective scatter index (OSI) and wavefront aberrations were analyzed and compared before surgery and at 1, 6 and 12 months after surgery. RESULTS: After the operation: (1) SE and astigmatism declined and UDVA increased significantly in both groups, and UDVA was better after SMILE than FS-LASIK. (2) SR and MTF cutoff reduced and OSI increased significantly after SMILE and FS-LASIK. SR and MTF cutoff were significantly higher after SMILE than FS-LASIK. OSI was significantly lower after SMILE than FS-LASIK. (3) The total wavefront aberration, total low-order wavefront aberration, defocus and astigmatism aberration as well as trefoil aberration reduced significantly in both groups. The total high-order wavefront aberration increased significantly after FS-LASIK. The spherical and coma aberration increased significantly in both groups. The total high-order wavefront aberration and coma aberration at 1 month were higher after FS-LASIK than SMILE. CONCLUSION: The optical quality descended after SMILE and FS-LASIK. SMILE was superior to FS-LASIK at the correction effect and optical quality for high myopia. The combination of OQAS and iTrace analyzer is a valuable complementary measurement in evaluating the optical quality after the refractive surgery. TRIAL REGISTRATION: This is a retrospective study. This research was approved by the ethics committee of Xiangya Hospital and the IRB approval number is 201612074. BioMed Central 2021-08-02 /pmc/articles/PMC8330115/ /pubmed/34340669 http://dx.doi.org/10.1186/s12886-021-02048-5 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Yin, Yewei Lu, Ying Xiang, Aiqun Fu, Yanyan Zhao, Yang Li, Yuanjun Hu, Tu Du, Kaixuan Hu, Shengfa Fu, Qiuman Wu, Xiaoying Wen, Dan Comparison of the optical quality after SMILE and FS-LASIK for high myopia by OQAS and iTrace analyzer: a one-year retrospective study |
title | Comparison of the optical quality after SMILE and FS-LASIK for high myopia by OQAS and iTrace analyzer: a one-year retrospective study |
title_full | Comparison of the optical quality after SMILE and FS-LASIK for high myopia by OQAS and iTrace analyzer: a one-year retrospective study |
title_fullStr | Comparison of the optical quality after SMILE and FS-LASIK for high myopia by OQAS and iTrace analyzer: a one-year retrospective study |
title_full_unstemmed | Comparison of the optical quality after SMILE and FS-LASIK for high myopia by OQAS and iTrace analyzer: a one-year retrospective study |
title_short | Comparison of the optical quality after SMILE and FS-LASIK for high myopia by OQAS and iTrace analyzer: a one-year retrospective study |
title_sort | comparison of the optical quality after smile and fs-lasik for high myopia by oqas and itrace analyzer: a one-year retrospective study |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8330115/ https://www.ncbi.nlm.nih.gov/pubmed/34340669 http://dx.doi.org/10.1186/s12886-021-02048-5 |
work_keys_str_mv | AT yinyewei comparisonoftheopticalqualityaftersmileandfslasikforhighmyopiabyoqasanditraceanalyzeraoneyearretrospectivestudy AT luying comparisonoftheopticalqualityaftersmileandfslasikforhighmyopiabyoqasanditraceanalyzeraoneyearretrospectivestudy AT xiangaiqun comparisonoftheopticalqualityaftersmileandfslasikforhighmyopiabyoqasanditraceanalyzeraoneyearretrospectivestudy AT fuyanyan comparisonoftheopticalqualityaftersmileandfslasikforhighmyopiabyoqasanditraceanalyzeraoneyearretrospectivestudy AT zhaoyang comparisonoftheopticalqualityaftersmileandfslasikforhighmyopiabyoqasanditraceanalyzeraoneyearretrospectivestudy AT liyuanjun comparisonoftheopticalqualityaftersmileandfslasikforhighmyopiabyoqasanditraceanalyzeraoneyearretrospectivestudy AT hutu comparisonoftheopticalqualityaftersmileandfslasikforhighmyopiabyoqasanditraceanalyzeraoneyearretrospectivestudy AT dukaixuan comparisonoftheopticalqualityaftersmileandfslasikforhighmyopiabyoqasanditraceanalyzeraoneyearretrospectivestudy AT hushengfa comparisonoftheopticalqualityaftersmileandfslasikforhighmyopiabyoqasanditraceanalyzeraoneyearretrospectivestudy AT fuqiuman comparisonoftheopticalqualityaftersmileandfslasikforhighmyopiabyoqasanditraceanalyzeraoneyearretrospectivestudy AT wuxiaoying comparisonoftheopticalqualityaftersmileandfslasikforhighmyopiabyoqasanditraceanalyzeraoneyearretrospectivestudy AT wendan comparisonoftheopticalqualityaftersmileandfslasikforhighmyopiabyoqasanditraceanalyzeraoneyearretrospectivestudy |