Cargando…

A High-Sensitivity Method Based on Advanced Optical Waveguide Technology to Detect HBsAg

A novel method for the detection of the hepatitis B surface antigen (HBsAg) at low concentrations, using the ultrahigh-order guided mode acting as the probe excited by a symmetrical metal-cladding waveguide, is proposed. The method using the fact of the minimum value of the absorption peaks is propo...

Descripción completa

Detalles Bibliográficos
Autores principales: Xiao, Pingping, Hu, Xiaoxiong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8331295/
https://www.ncbi.nlm.nih.gov/pubmed/34354809
http://dx.doi.org/10.1155/2021/8719147
_version_ 1783732890499022848
author Xiao, Pingping
Hu, Xiaoxiong
author_facet Xiao, Pingping
Hu, Xiaoxiong
author_sort Xiao, Pingping
collection PubMed
description A novel method for the detection of the hepatitis B surface antigen (HBsAg) at low concentrations, using the ultrahigh-order guided mode acting as the probe excited by a symmetrical metal-cladding waveguide, is proposed. The method using the fact of the minimum value of the absorption peaks is proportional to the concentration of the sample to be detected to realize the detection of the hepatitis B virus at extremely low concentrations. It is realized that the low concentration of the HBsAg measurement relied on the principle of the minimum value of the absorption peak and the concentration having a good linear relationship. The measurement results indicate that this new method can precisely detect HBsAg at the concentrations in the lower region of the clinical gray area (i.e., below 20 ng/mL), the lower region of the current clinical gray area of HBsAg (below 20 ng/ml) can be measured, and the resolution can be reached (2 ng/mL).
format Online
Article
Text
id pubmed-8331295
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-83312952021-08-04 A High-Sensitivity Method Based on Advanced Optical Waveguide Technology to Detect HBsAg Xiao, Pingping Hu, Xiaoxiong J Healthc Eng Research Article A novel method for the detection of the hepatitis B surface antigen (HBsAg) at low concentrations, using the ultrahigh-order guided mode acting as the probe excited by a symmetrical metal-cladding waveguide, is proposed. The method using the fact of the minimum value of the absorption peaks is proportional to the concentration of the sample to be detected to realize the detection of the hepatitis B virus at extremely low concentrations. It is realized that the low concentration of the HBsAg measurement relied on the principle of the minimum value of the absorption peak and the concentration having a good linear relationship. The measurement results indicate that this new method can precisely detect HBsAg at the concentrations in the lower region of the clinical gray area (i.e., below 20 ng/mL), the lower region of the current clinical gray area of HBsAg (below 20 ng/ml) can be measured, and the resolution can be reached (2 ng/mL). Hindawi 2021-07-26 /pmc/articles/PMC8331295/ /pubmed/34354809 http://dx.doi.org/10.1155/2021/8719147 Text en Copyright © 2021 Pingping Xiao and Xiaoxiong Hu. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Xiao, Pingping
Hu, Xiaoxiong
A High-Sensitivity Method Based on Advanced Optical Waveguide Technology to Detect HBsAg
title A High-Sensitivity Method Based on Advanced Optical Waveguide Technology to Detect HBsAg
title_full A High-Sensitivity Method Based on Advanced Optical Waveguide Technology to Detect HBsAg
title_fullStr A High-Sensitivity Method Based on Advanced Optical Waveguide Technology to Detect HBsAg
title_full_unstemmed A High-Sensitivity Method Based on Advanced Optical Waveguide Technology to Detect HBsAg
title_short A High-Sensitivity Method Based on Advanced Optical Waveguide Technology to Detect HBsAg
title_sort high-sensitivity method based on advanced optical waveguide technology to detect hbsag
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8331295/
https://www.ncbi.nlm.nih.gov/pubmed/34354809
http://dx.doi.org/10.1155/2021/8719147
work_keys_str_mv AT xiaopingping ahighsensitivitymethodbasedonadvancedopticalwaveguidetechnologytodetecthbsag
AT huxiaoxiong ahighsensitivitymethodbasedonadvancedopticalwaveguidetechnologytodetecthbsag
AT xiaopingping highsensitivitymethodbasedonadvancedopticalwaveguidetechnologytodetecthbsag
AT huxiaoxiong highsensitivitymethodbasedonadvancedopticalwaveguidetechnologytodetecthbsag