Cargando…
A High-Sensitivity Method Based on Advanced Optical Waveguide Technology to Detect HBsAg
A novel method for the detection of the hepatitis B surface antigen (HBsAg) at low concentrations, using the ultrahigh-order guided mode acting as the probe excited by a symmetrical metal-cladding waveguide, is proposed. The method using the fact of the minimum value of the absorption peaks is propo...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8331295/ https://www.ncbi.nlm.nih.gov/pubmed/34354809 http://dx.doi.org/10.1155/2021/8719147 |
_version_ | 1783732890499022848 |
---|---|
author | Xiao, Pingping Hu, Xiaoxiong |
author_facet | Xiao, Pingping Hu, Xiaoxiong |
author_sort | Xiao, Pingping |
collection | PubMed |
description | A novel method for the detection of the hepatitis B surface antigen (HBsAg) at low concentrations, using the ultrahigh-order guided mode acting as the probe excited by a symmetrical metal-cladding waveguide, is proposed. The method using the fact of the minimum value of the absorption peaks is proportional to the concentration of the sample to be detected to realize the detection of the hepatitis B virus at extremely low concentrations. It is realized that the low concentration of the HBsAg measurement relied on the principle of the minimum value of the absorption peak and the concentration having a good linear relationship. The measurement results indicate that this new method can precisely detect HBsAg at the concentrations in the lower region of the clinical gray area (i.e., below 20 ng/mL), the lower region of the current clinical gray area of HBsAg (below 20 ng/ml) can be measured, and the resolution can be reached (2 ng/mL). |
format | Online Article Text |
id | pubmed-8331295 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-83312952021-08-04 A High-Sensitivity Method Based on Advanced Optical Waveguide Technology to Detect HBsAg Xiao, Pingping Hu, Xiaoxiong J Healthc Eng Research Article A novel method for the detection of the hepatitis B surface antigen (HBsAg) at low concentrations, using the ultrahigh-order guided mode acting as the probe excited by a symmetrical metal-cladding waveguide, is proposed. The method using the fact of the minimum value of the absorption peaks is proportional to the concentration of the sample to be detected to realize the detection of the hepatitis B virus at extremely low concentrations. It is realized that the low concentration of the HBsAg measurement relied on the principle of the minimum value of the absorption peak and the concentration having a good linear relationship. The measurement results indicate that this new method can precisely detect HBsAg at the concentrations in the lower region of the clinical gray area (i.e., below 20 ng/mL), the lower region of the current clinical gray area of HBsAg (below 20 ng/ml) can be measured, and the resolution can be reached (2 ng/mL). Hindawi 2021-07-26 /pmc/articles/PMC8331295/ /pubmed/34354809 http://dx.doi.org/10.1155/2021/8719147 Text en Copyright © 2021 Pingping Xiao and Xiaoxiong Hu. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Xiao, Pingping Hu, Xiaoxiong A High-Sensitivity Method Based on Advanced Optical Waveguide Technology to Detect HBsAg |
title | A High-Sensitivity Method Based on Advanced Optical Waveguide Technology to Detect HBsAg |
title_full | A High-Sensitivity Method Based on Advanced Optical Waveguide Technology to Detect HBsAg |
title_fullStr | A High-Sensitivity Method Based on Advanced Optical Waveguide Technology to Detect HBsAg |
title_full_unstemmed | A High-Sensitivity Method Based on Advanced Optical Waveguide Technology to Detect HBsAg |
title_short | A High-Sensitivity Method Based on Advanced Optical Waveguide Technology to Detect HBsAg |
title_sort | high-sensitivity method based on advanced optical waveguide technology to detect hbsag |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8331295/ https://www.ncbi.nlm.nih.gov/pubmed/34354809 http://dx.doi.org/10.1155/2021/8719147 |
work_keys_str_mv | AT xiaopingping ahighsensitivitymethodbasedonadvancedopticalwaveguidetechnologytodetecthbsag AT huxiaoxiong ahighsensitivitymethodbasedonadvancedopticalwaveguidetechnologytodetecthbsag AT xiaopingping highsensitivitymethodbasedonadvancedopticalwaveguidetechnologytodetecthbsag AT huxiaoxiong highsensitivitymethodbasedonadvancedopticalwaveguidetechnologytodetecthbsag |