Cargando…
Surgical Drill Guide for Insertion of an Infra-Acetabular Screw Based on an Anatomically Precontoured Plate System: A Cadaveric Study
PURPOSE: Due to the anatomic structure of the pelvis, free-hand placement of screws in the acetabular fracture management can be difficult. Infra-acetabular screw fixation increases acetabular stability by distal fixation of the cup. Aim of this cadaveric study is to investigate if a plate-reference...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8331300/ https://www.ncbi.nlm.nih.gov/pubmed/34355040 http://dx.doi.org/10.1155/2021/2321504 |
_version_ | 1783732894522408960 |
---|---|
author | Freigang, Viola Gottsauner, Maximilian Rupp, Markus Pfeifer, Christian Grechenig, Stephan Kerner, Alexander Alt, Volker Baumann, Florian |
author_facet | Freigang, Viola Gottsauner, Maximilian Rupp, Markus Pfeifer, Christian Grechenig, Stephan Kerner, Alexander Alt, Volker Baumann, Florian |
author_sort | Freigang, Viola |
collection | PubMed |
description | PURPOSE: Due to the anatomic structure of the pelvis, free-hand placement of screws in the acetabular fracture management can be difficult. Infra-acetabular screw fixation increases acetabular stability by distal fixation of the cup. Aim of this cadaveric study is to investigate if a plate-referenced drill guide can provide save placement of an infra-acetabular screw over a precontoured suprapectineal quadrilateral buttress plate (SQBP). METHODS: We constructed a drill guide for an infra-acetabular screw based on the surface of an anatomically precontoured SQBP. A total of 12 adult cadaveric acetabular specimens were used for drill guide-assisted placement of the infra-acetabular screw. The drill guide contains a radiopaque spiral to allow longitudinal fine adjustment of the SQBP along the pelvic brim to assure correct position of the plate-drill-guide construct in relation to the Koehler's teardrop. After screw placement, we conducted a computed tomography (CT) scan of all specimens to assess the actual position of the screw in relation of the infra-acetabular corridor and the acetabular joint surface. RESULTS: The position of the screw was within the infra-acetabular corridor in all cases. We did not see any intra-articular or intrapelvic screw penetration. The mean distance of the centerline of the screw to the medial border of the infra-acetabular corridor was 3.35 mm. The secure distance to the virtual surface of the femoral head to was 7.3 mm. CONCLUSIONS: A plate-referenced drill guide can provide safe placement of an infra-acetabular screw for treatment of acetabular fractures. Radiographic fine adjustment is necessary to access the optimal entry point. |
format | Online Article Text |
id | pubmed-8331300 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-83313002021-08-04 Surgical Drill Guide for Insertion of an Infra-Acetabular Screw Based on an Anatomically Precontoured Plate System: A Cadaveric Study Freigang, Viola Gottsauner, Maximilian Rupp, Markus Pfeifer, Christian Grechenig, Stephan Kerner, Alexander Alt, Volker Baumann, Florian Biomed Res Int Research Article PURPOSE: Due to the anatomic structure of the pelvis, free-hand placement of screws in the acetabular fracture management can be difficult. Infra-acetabular screw fixation increases acetabular stability by distal fixation of the cup. Aim of this cadaveric study is to investigate if a plate-referenced drill guide can provide save placement of an infra-acetabular screw over a precontoured suprapectineal quadrilateral buttress plate (SQBP). METHODS: We constructed a drill guide for an infra-acetabular screw based on the surface of an anatomically precontoured SQBP. A total of 12 adult cadaveric acetabular specimens were used for drill guide-assisted placement of the infra-acetabular screw. The drill guide contains a radiopaque spiral to allow longitudinal fine adjustment of the SQBP along the pelvic brim to assure correct position of the plate-drill-guide construct in relation to the Koehler's teardrop. After screw placement, we conducted a computed tomography (CT) scan of all specimens to assess the actual position of the screw in relation of the infra-acetabular corridor and the acetabular joint surface. RESULTS: The position of the screw was within the infra-acetabular corridor in all cases. We did not see any intra-articular or intrapelvic screw penetration. The mean distance of the centerline of the screw to the medial border of the infra-acetabular corridor was 3.35 mm. The secure distance to the virtual surface of the femoral head to was 7.3 mm. CONCLUSIONS: A plate-referenced drill guide can provide safe placement of an infra-acetabular screw for treatment of acetabular fractures. Radiographic fine adjustment is necessary to access the optimal entry point. Hindawi 2021-07-26 /pmc/articles/PMC8331300/ /pubmed/34355040 http://dx.doi.org/10.1155/2021/2321504 Text en Copyright © 2021 Viola Freigang et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article Freigang, Viola Gottsauner, Maximilian Rupp, Markus Pfeifer, Christian Grechenig, Stephan Kerner, Alexander Alt, Volker Baumann, Florian Surgical Drill Guide for Insertion of an Infra-Acetabular Screw Based on an Anatomically Precontoured Plate System: A Cadaveric Study |
title | Surgical Drill Guide for Insertion of an Infra-Acetabular Screw Based on an Anatomically Precontoured Plate System: A Cadaveric Study |
title_full | Surgical Drill Guide for Insertion of an Infra-Acetabular Screw Based on an Anatomically Precontoured Plate System: A Cadaveric Study |
title_fullStr | Surgical Drill Guide for Insertion of an Infra-Acetabular Screw Based on an Anatomically Precontoured Plate System: A Cadaveric Study |
title_full_unstemmed | Surgical Drill Guide for Insertion of an Infra-Acetabular Screw Based on an Anatomically Precontoured Plate System: A Cadaveric Study |
title_short | Surgical Drill Guide for Insertion of an Infra-Acetabular Screw Based on an Anatomically Precontoured Plate System: A Cadaveric Study |
title_sort | surgical drill guide for insertion of an infra-acetabular screw based on an anatomically precontoured plate system: a cadaveric study |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8331300/ https://www.ncbi.nlm.nih.gov/pubmed/34355040 http://dx.doi.org/10.1155/2021/2321504 |
work_keys_str_mv | AT freigangviola surgicaldrillguideforinsertionofaninfraacetabularscrewbasedonananatomicallyprecontouredplatesystemacadavericstudy AT gottsaunermaximilian surgicaldrillguideforinsertionofaninfraacetabularscrewbasedonananatomicallyprecontouredplatesystemacadavericstudy AT ruppmarkus surgicaldrillguideforinsertionofaninfraacetabularscrewbasedonananatomicallyprecontouredplatesystemacadavericstudy AT pfeiferchristian surgicaldrillguideforinsertionofaninfraacetabularscrewbasedonananatomicallyprecontouredplatesystemacadavericstudy AT grechenigstephan surgicaldrillguideforinsertionofaninfraacetabularscrewbasedonananatomicallyprecontouredplatesystemacadavericstudy AT kerneralexander surgicaldrillguideforinsertionofaninfraacetabularscrewbasedonananatomicallyprecontouredplatesystemacadavericstudy AT altvolker surgicaldrillguideforinsertionofaninfraacetabularscrewbasedonananatomicallyprecontouredplatesystemacadavericstudy AT baumannflorian surgicaldrillguideforinsertionofaninfraacetabularscrewbasedonananatomicallyprecontouredplatesystemacadavericstudy |