Cargando…

Solidified floating organic droplet microextraction coupled with HPLC for rapid determination of trans, trans muconic acid in benzene biomonitoring

Benzene is one of the carcinogenic compounds in the work environments. Exposure assessment of benzene through biological monitoring is an acceptable way to accurately measure the real exposure in order to conducting the health risk assessment, but it is always complicated, laborious, time consuming...

Descripción completa

Detalles Bibliográficos
Autores principales: Dehghani, Fatemeh, Omidi, Fariborz, Heravizadeh, Omidreza, Yousefinejad, Saeed
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8333051/
https://www.ncbi.nlm.nih.gov/pubmed/34344921
http://dx.doi.org/10.1038/s41598-021-95174-5
_version_ 1783732960232472576
author Dehghani, Fatemeh
Omidi, Fariborz
Heravizadeh, Omidreza
Yousefinejad, Saeed
author_facet Dehghani, Fatemeh
Omidi, Fariborz
Heravizadeh, Omidreza
Yousefinejad, Saeed
author_sort Dehghani, Fatemeh
collection PubMed
description Benzene is one of the carcinogenic compounds in the work environments. Exposure assessment of benzene through biological monitoring is an acceptable way to accurately measure the real exposure in order to conducting the health risk assessment, but it is always complicated, laborious, time consuming and costly process. A new sensitive, simple, fast and environmental friendly method was developed for the determination of urinary metabolite of benzene, trans trans muconic acid (t,t-MA) by dispersive liquid–liquid micro extraction based on solidification of floating organic droplet coupled with high-performance liquid chromatography with ultra violet detector. Central composite design methodology was utilized to evaluate the effective factors on the extraction output of the target metabolite. The calibration curve was plotted in the concentration ranges of 0.02–5 µg mL(−1). The precision and accuracy of the method were assayed via the relative standard deviation (RSD%) and relative recovery (RR%) using spiked samples with three replications. The RR% and RSD% of the optimized method were 86.9–91.3% and 4.3–6.3% respectively. The limit of detection (LOD) of the method was 0.006 µg mL(−1). The level of t,t-MA in real samples was ranged from 0.54 to 1.64 mg/g creatinine. We demonstrated that t,t-MA can be extracted and determined by an inexpensive, simple and fast method.
format Online
Article
Text
id pubmed-8333051
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-83330512021-08-04 Solidified floating organic droplet microextraction coupled with HPLC for rapid determination of trans, trans muconic acid in benzene biomonitoring Dehghani, Fatemeh Omidi, Fariborz Heravizadeh, Omidreza Yousefinejad, Saeed Sci Rep Article Benzene is one of the carcinogenic compounds in the work environments. Exposure assessment of benzene through biological monitoring is an acceptable way to accurately measure the real exposure in order to conducting the health risk assessment, but it is always complicated, laborious, time consuming and costly process. A new sensitive, simple, fast and environmental friendly method was developed for the determination of urinary metabolite of benzene, trans trans muconic acid (t,t-MA) by dispersive liquid–liquid micro extraction based on solidification of floating organic droplet coupled with high-performance liquid chromatography with ultra violet detector. Central composite design methodology was utilized to evaluate the effective factors on the extraction output of the target metabolite. The calibration curve was plotted in the concentration ranges of 0.02–5 µg mL(−1). The precision and accuracy of the method were assayed via the relative standard deviation (RSD%) and relative recovery (RR%) using spiked samples with three replications. The RR% and RSD% of the optimized method were 86.9–91.3% and 4.3–6.3% respectively. The limit of detection (LOD) of the method was 0.006 µg mL(−1). The level of t,t-MA in real samples was ranged from 0.54 to 1.64 mg/g creatinine. We demonstrated that t,t-MA can be extracted and determined by an inexpensive, simple and fast method. Nature Publishing Group UK 2021-08-03 /pmc/articles/PMC8333051/ /pubmed/34344921 http://dx.doi.org/10.1038/s41598-021-95174-5 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Dehghani, Fatemeh
Omidi, Fariborz
Heravizadeh, Omidreza
Yousefinejad, Saeed
Solidified floating organic droplet microextraction coupled with HPLC for rapid determination of trans, trans muconic acid in benzene biomonitoring
title Solidified floating organic droplet microextraction coupled with HPLC for rapid determination of trans, trans muconic acid in benzene biomonitoring
title_full Solidified floating organic droplet microextraction coupled with HPLC for rapid determination of trans, trans muconic acid in benzene biomonitoring
title_fullStr Solidified floating organic droplet microextraction coupled with HPLC for rapid determination of trans, trans muconic acid in benzene biomonitoring
title_full_unstemmed Solidified floating organic droplet microextraction coupled with HPLC for rapid determination of trans, trans muconic acid in benzene biomonitoring
title_short Solidified floating organic droplet microextraction coupled with HPLC for rapid determination of trans, trans muconic acid in benzene biomonitoring
title_sort solidified floating organic droplet microextraction coupled with hplc for rapid determination of trans, trans muconic acid in benzene biomonitoring
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8333051/
https://www.ncbi.nlm.nih.gov/pubmed/34344921
http://dx.doi.org/10.1038/s41598-021-95174-5
work_keys_str_mv AT dehghanifatemeh solidifiedfloatingorganicdropletmicroextractioncoupledwithhplcforrapiddeterminationoftranstransmuconicacidinbenzenebiomonitoring
AT omidifariborz solidifiedfloatingorganicdropletmicroextractioncoupledwithhplcforrapiddeterminationoftranstransmuconicacidinbenzenebiomonitoring
AT heravizadehomidreza solidifiedfloatingorganicdropletmicroextractioncoupledwithhplcforrapiddeterminationoftranstransmuconicacidinbenzenebiomonitoring
AT yousefinejadsaeed solidifiedfloatingorganicdropletmicroextractioncoupledwithhplcforrapiddeterminationoftranstransmuconicacidinbenzenebiomonitoring