Cargando…

Reducing healthcare-associated infections by improving compliance to aseptic non-touch technique in intravenous line maintenance: a quality improvement approach

BACKGROUND: Lack of standardisation and failure to maintain aseptic techniques during procedures contributes to healthcare-associated infections (HCAI). Although numerous procedures are performed in neonatal intensive care units (NICU), handling peripheral intravenous lines is one of the simple and...

Descripción completa

Detalles Bibliográficos
Autores principales: Shettigar, Savithri, Somasekhara Aradhya, Abhishek, Ramappa, Srinath, Reddy, Venugopal, Venkatagiri, Praveen
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8336114/
https://www.ncbi.nlm.nih.gov/pubmed/34344750
http://dx.doi.org/10.1136/bmjoq-2021-001394
_version_ 1783733260985040896
author Shettigar, Savithri
Somasekhara Aradhya, Abhishek
Ramappa, Srinath
Reddy, Venugopal
Venkatagiri, Praveen
author_facet Shettigar, Savithri
Somasekhara Aradhya, Abhishek
Ramappa, Srinath
Reddy, Venugopal
Venkatagiri, Praveen
author_sort Shettigar, Savithri
collection PubMed
description BACKGROUND: Lack of standardisation and failure to maintain aseptic techniques during procedures contributes to healthcare-associated infections (HCAI). Although numerous procedures are performed in neonatal intensive care units (NICU), handling peripheral intravenous lines is one of the simple and common procedures performed daily. Despite evidence-based care bundle approach variability is higher, and compliance to asepsis is less in routine clinical practice. In this study, we aimed to standardise and improve compliance with Aseptic non-technique (ANTT) in intravenous line maintenance of neonates admitted to NICU to reduce HCAI by 50% over 6 months. METHODS: All nurses were subjects of assessment for compliance with intravenous line maintenance. All admitted neonates with intravenous lines were subjects for the HCAI data collection. At baseline, the current practices for intravenous line maintenance were observed on a generic ANTT audit proforma. Pictorial standard operating procedure (SOP) was developed based on ANTT. Implementation and sustenance were ensured by Plan-Do-Study-Act cycles. Audit data on compliance to ANTT and trends of HCAI rates were displayed using run charts monthly. Qualitative experience from the nursing staff was also recorded. RESULTS: Significant improvement was seen in compliance to various components—use of the aseptic field (0% to 100%), closed ports (0% to 100%), key part contamination reduction (80% to 0%), and intravenous hub scrubbing (0% to 72%). SOP of intravenous line maintenance based on ANTT could be implemented and sustained throughout for 9 months. There was a reduction of HCAI from 26 per 1000 patient days to 8 per 1000 patient days. Qualitative experience showed the main determinant of compliance to scrub the hub was the neonate’s sickness level. CONCLUSIONS: Using a quality improvement model of improvement, ANTT in intravenous line maintenance was implemented stepwise. Improving compliance with ANTT principles in intravenous line maintenance reduced HCAI. Scrub the hub requires longer sustained efforts to become part of the practice.
format Online
Article
Text
id pubmed-8336114
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BMJ Publishing Group
record_format MEDLINE/PubMed
spelling pubmed-83361142021-08-20 Reducing healthcare-associated infections by improving compliance to aseptic non-touch technique in intravenous line maintenance: a quality improvement approach Shettigar, Savithri Somasekhara Aradhya, Abhishek Ramappa, Srinath Reddy, Venugopal Venkatagiri, Praveen BMJ Open Qual Quality Improvement Report BACKGROUND: Lack of standardisation and failure to maintain aseptic techniques during procedures contributes to healthcare-associated infections (HCAI). Although numerous procedures are performed in neonatal intensive care units (NICU), handling peripheral intravenous lines is one of the simple and common procedures performed daily. Despite evidence-based care bundle approach variability is higher, and compliance to asepsis is less in routine clinical practice. In this study, we aimed to standardise and improve compliance with Aseptic non-technique (ANTT) in intravenous line maintenance of neonates admitted to NICU to reduce HCAI by 50% over 6 months. METHODS: All nurses were subjects of assessment for compliance with intravenous line maintenance. All admitted neonates with intravenous lines were subjects for the HCAI data collection. At baseline, the current practices for intravenous line maintenance were observed on a generic ANTT audit proforma. Pictorial standard operating procedure (SOP) was developed based on ANTT. Implementation and sustenance were ensured by Plan-Do-Study-Act cycles. Audit data on compliance to ANTT and trends of HCAI rates were displayed using run charts monthly. Qualitative experience from the nursing staff was also recorded. RESULTS: Significant improvement was seen in compliance to various components—use of the aseptic field (0% to 100%), closed ports (0% to 100%), key part contamination reduction (80% to 0%), and intravenous hub scrubbing (0% to 72%). SOP of intravenous line maintenance based on ANTT could be implemented and sustained throughout for 9 months. There was a reduction of HCAI from 26 per 1000 patient days to 8 per 1000 patient days. Qualitative experience showed the main determinant of compliance to scrub the hub was the neonate’s sickness level. CONCLUSIONS: Using a quality improvement model of improvement, ANTT in intravenous line maintenance was implemented stepwise. Improving compliance with ANTT principles in intravenous line maintenance reduced HCAI. Scrub the hub requires longer sustained efforts to become part of the practice. BMJ Publishing Group 2021-08-03 /pmc/articles/PMC8336114/ /pubmed/34344750 http://dx.doi.org/10.1136/bmjoq-2021-001394 Text en © Author(s) (or their employer(s)) 2021. Re-use permitted under CC BY-NC. No commercial re-use. See rights and permissions. Published by BMJ. https://creativecommons.org/licenses/by-nc/4.0/This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) .
spellingShingle Quality Improvement Report
Shettigar, Savithri
Somasekhara Aradhya, Abhishek
Ramappa, Srinath
Reddy, Venugopal
Venkatagiri, Praveen
Reducing healthcare-associated infections by improving compliance to aseptic non-touch technique in intravenous line maintenance: a quality improvement approach
title Reducing healthcare-associated infections by improving compliance to aseptic non-touch technique in intravenous line maintenance: a quality improvement approach
title_full Reducing healthcare-associated infections by improving compliance to aseptic non-touch technique in intravenous line maintenance: a quality improvement approach
title_fullStr Reducing healthcare-associated infections by improving compliance to aseptic non-touch technique in intravenous line maintenance: a quality improvement approach
title_full_unstemmed Reducing healthcare-associated infections by improving compliance to aseptic non-touch technique in intravenous line maintenance: a quality improvement approach
title_short Reducing healthcare-associated infections by improving compliance to aseptic non-touch technique in intravenous line maintenance: a quality improvement approach
title_sort reducing healthcare-associated infections by improving compliance to aseptic non-touch technique in intravenous line maintenance: a quality improvement approach
topic Quality Improvement Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8336114/
https://www.ncbi.nlm.nih.gov/pubmed/34344750
http://dx.doi.org/10.1136/bmjoq-2021-001394
work_keys_str_mv AT shettigarsavithri reducinghealthcareassociatedinfectionsbyimprovingcompliancetoasepticnontouchtechniqueinintravenouslinemaintenanceaqualityimprovementapproach
AT somasekharaaradhyaabhishek reducinghealthcareassociatedinfectionsbyimprovingcompliancetoasepticnontouchtechniqueinintravenouslinemaintenanceaqualityimprovementapproach
AT ramappasrinath reducinghealthcareassociatedinfectionsbyimprovingcompliancetoasepticnontouchtechniqueinintravenouslinemaintenanceaqualityimprovementapproach
AT reddyvenugopal reducinghealthcareassociatedinfectionsbyimprovingcompliancetoasepticnontouchtechniqueinintravenouslinemaintenanceaqualityimprovementapproach
AT venkatagiripraveen reducinghealthcareassociatedinfectionsbyimprovingcompliancetoasepticnontouchtechniqueinintravenouslinemaintenanceaqualityimprovementapproach