Cargando…
A torque induced iatrogenic fracture of the humeral shaft in proximal humeral fracture plating – A case report and biomechanical perspectives
INTRODUCTION: Proximal humerus fractures are common amongst the elderly and osteoporotic cohorts. Common treatment methods include proximal locking plates. In this case, we describe an iatrogenic fracture of the proximal humeral shaft during screw insertion under power. Similar cases have not been d...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8339138/ https://www.ncbi.nlm.nih.gov/pubmed/34381603 http://dx.doi.org/10.1016/j.amsu.2021.102615 |
_version_ | 1783733534786060288 |
---|---|
author | Lari, Ali Alherz, Mohammad Jarragh, Ali |
author_facet | Lari, Ali Alherz, Mohammad Jarragh, Ali |
author_sort | Lari, Ali |
collection | PubMed |
description | INTRODUCTION: Proximal humerus fractures are common amongst the elderly and osteoporotic cohorts. Common treatment methods include proximal locking plates. In this case, we describe an iatrogenic fracture of the proximal humeral shaft during screw insertion under power. Similar cases have not been described previously in open reduction and internal fixation of a proximal humerus fracture. Further, we focus particularly on precautionary measures that aim to avoid such complications that may lead to considerable morbidity. CASE PRESENTATION: We describe a case of a 65 year old osteoporotic female who underwent open reduction internal fixation of a proximal humerus fracture complicated by an unusual iatrogenic humeral fracture at the level of insertion of the distal screw, likely secondary to inserting the proximal locking screws under power. CONCLUSION: In this case, we explore the possible factors leading to the fracture and precautionary measures to avoid them. The rate of iatrogenic intraoperative fractures are likely underreported and have not been described in open reduction and internal fixation of an existing fracture. The underlying factors that may predispose to such complications have not been previously described in similar cases. This case serves as a warning of an unanticipated complication and describes the potential biomechanical factors involved. |
format | Online Article Text |
id | pubmed-8339138 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-83391382021-08-10 A torque induced iatrogenic fracture of the humeral shaft in proximal humeral fracture plating – A case report and biomechanical perspectives Lari, Ali Alherz, Mohammad Jarragh, Ali Ann Med Surg (Lond) Case Report INTRODUCTION: Proximal humerus fractures are common amongst the elderly and osteoporotic cohorts. Common treatment methods include proximal locking plates. In this case, we describe an iatrogenic fracture of the proximal humeral shaft during screw insertion under power. Similar cases have not been described previously in open reduction and internal fixation of a proximal humerus fracture. Further, we focus particularly on precautionary measures that aim to avoid such complications that may lead to considerable morbidity. CASE PRESENTATION: We describe a case of a 65 year old osteoporotic female who underwent open reduction internal fixation of a proximal humerus fracture complicated by an unusual iatrogenic humeral fracture at the level of insertion of the distal screw, likely secondary to inserting the proximal locking screws under power. CONCLUSION: In this case, we explore the possible factors leading to the fracture and precautionary measures to avoid them. The rate of iatrogenic intraoperative fractures are likely underreported and have not been described in open reduction and internal fixation of an existing fracture. The underlying factors that may predispose to such complications have not been previously described in similar cases. This case serves as a warning of an unanticipated complication and describes the potential biomechanical factors involved. Elsevier 2021-07-27 /pmc/articles/PMC8339138/ /pubmed/34381603 http://dx.doi.org/10.1016/j.amsu.2021.102615 Text en © 2021 The Authors https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Case Report Lari, Ali Alherz, Mohammad Jarragh, Ali A torque induced iatrogenic fracture of the humeral shaft in proximal humeral fracture plating – A case report and biomechanical perspectives |
title | A torque induced iatrogenic fracture of the humeral shaft in proximal humeral fracture plating – A case report and biomechanical perspectives |
title_full | A torque induced iatrogenic fracture of the humeral shaft in proximal humeral fracture plating – A case report and biomechanical perspectives |
title_fullStr | A torque induced iatrogenic fracture of the humeral shaft in proximal humeral fracture plating – A case report and biomechanical perspectives |
title_full_unstemmed | A torque induced iatrogenic fracture of the humeral shaft in proximal humeral fracture plating – A case report and biomechanical perspectives |
title_short | A torque induced iatrogenic fracture of the humeral shaft in proximal humeral fracture plating – A case report and biomechanical perspectives |
title_sort | torque induced iatrogenic fracture of the humeral shaft in proximal humeral fracture plating – a case report and biomechanical perspectives |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8339138/ https://www.ncbi.nlm.nih.gov/pubmed/34381603 http://dx.doi.org/10.1016/j.amsu.2021.102615 |
work_keys_str_mv | AT lariali atorqueinducediatrogenicfractureofthehumeralshaftinproximalhumeralfractureplatingacasereportandbiomechanicalperspectives AT alherzmohammad atorqueinducediatrogenicfractureofthehumeralshaftinproximalhumeralfractureplatingacasereportandbiomechanicalperspectives AT jarraghali atorqueinducediatrogenicfractureofthehumeralshaftinproximalhumeralfractureplatingacasereportandbiomechanicalperspectives AT lariali torqueinducediatrogenicfractureofthehumeralshaftinproximalhumeralfractureplatingacasereportandbiomechanicalperspectives AT alherzmohammad torqueinducediatrogenicfractureofthehumeralshaftinproximalhumeralfractureplatingacasereportandbiomechanicalperspectives AT jarraghali torqueinducediatrogenicfractureofthehumeralshaftinproximalhumeralfractureplatingacasereportandbiomechanicalperspectives |