A torque induced iatrogenic fracture of the humeral shaft in proximal humeral fracture plating – A case report and biomechanical perspectives
INTRODUCTION: Proximal humerus fractures are common amongst the elderly and osteoporotic cohorts. Common treatment methods include proximal locking plates. In this case, we describe an iatrogenic fracture of the proximal humeral shaft during screw insertion under power. Similar cases have not been d...