Cargando…

Internationally validated score to predict the outcome of non-paroxysmal atrial fibrillation ablation: the ‘FLAME score’

BACKGROUND: The clinical effectiveness of ablating non-paroxysmal atrial fibrillation (non-PAF) relies on proper patient selection. We developed and validated a scoring system to predict non-PAF ablation outcomes. METHODS: Data on 416 non-PAF ablations were analysed using binary logistic regression...

Descripción completa

Detalles Bibliográficos
Autores principales: Boyalla, Vennela, Jarman, Julian W E, Markides, Vias, Hussain, Wajid, Wong, Tom, Mead, R Hardwin, Engel, Gregory, Kong, Melissa H, Patrawala, Rob A, Winkle, Roger A
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BMJ Publishing Group 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8340273/
https://www.ncbi.nlm.nih.gov/pubmed/34348972
http://dx.doi.org/10.1136/openhrt-2021-001653
Descripción
Sumario:BACKGROUND: The clinical effectiveness of ablating non-paroxysmal atrial fibrillation (non-PAF) relies on proper patient selection. We developed and validated a scoring system to predict non-PAF ablation outcomes. METHODS: Data on 416 non-PAF ablations were analysed using binary logistic regression at a London centre. Identified preprocedural variables, which independently predicted freedom from atrial tachyarrhythmia. Twenty-one possible predictive variables and a model with c-statistic 0.751—explained outcome variation in London at mean follow-up 12±3 months. An additive point score (range 0–9) was developed—the FLAME score: female=1; long-lasting persistent atrial fibrillation=1; left atrial diameter in mm: 40 to <45 = 1, 45 to <50 = 2, 50 to <55=3, ≥55 =4; mitral regurgitation (MR) mild to moderate=1; extreme comorbidity=2. Extreme comorbidities include severe MR, moderate mitral stenosis, mitral replacement, hypertrophic cardiomyopathy or congenital heart disease. RESULTS: The FLAME score was applied to data (882 non-PAF ablations) at a Californian centre, and predicted the outcome of both single (p<0.0001) and multiple (p<0.0001) procedures. For first ablation (follow-up 2.1 years (median, IQR 1.0–4.1)), FLAME score: 0–1 predicts 62% success, 2–4 44% and ≥5 29% (P(trend) <0.0001). After the final ablation (mean procedures: 1.4±0.6, follow-up 1.8 years (median, IQR 0.8–3.6)), FLAME score: 0–1 predicts 81% success, 2–4 65% and ≥5 44% (P(trend) <0.0001). CONCLUSIONS: FLAME score is easily calculated, derived in London, and predicted single and multiple procedural outcomes for non-PAF ablations in California. In patients with a high score, even multiple procedures are usually ineffective.