Cargando…
Simplified sleep resistance test for daytime sleepiness detection
OBJECTIVES: Excessive daytime sleepiness (EDS) is a highly prevalent symptom that increases the risk of traffic accidents and deteriorates the quality of life. The diagnosis of EDS is difficult because of the complex infrastructure that is required. The new test here proposed assesses the ability of...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Brazilian Association of Sleep and Latin American Federation of
Sleep
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8340892/ https://www.ncbi.nlm.nih.gov/pubmed/34381580 http://dx.doi.org/10.5935/1984-0063.20200046 |
_version_ | 1783733844048871424 |
---|---|
author | Larrateguy, Luis Darío Pais, Carlos M. Larrateguy, Luis I. Larrateguy, Santiago D. Schlotthauer, Gaston |
author_facet | Larrateguy, Luis Darío Pais, Carlos M. Larrateguy, Luis I. Larrateguy, Santiago D. Schlotthauer, Gaston |
author_sort | Larrateguy, Luis Darío |
collection | PubMed |
description | OBJECTIVES: Excessive daytime sleepiness (EDS) is a highly prevalent symptom that increases the risk of traffic accidents and deteriorates the quality of life. The diagnosis of EDS is difficult because of the complex infrastructure that is required. The new test here proposed assesses the ability of a simple test of simplify the detection of daytime sleepiness compared with the OSLER test. MATERIAL AND METHODS: In the new test, during 20 minute subjects were asked to pass a finger by a groove in response to a light emitting diode, inside dark glasses, which was lit for 1s in every three, with headphones that reduce the ambient noise and was compared with the OSLER test on each subject in random order. RESULTS: The proposed method showed a sensitivity of 100% and a specificity of 61%, with a positive predictive value of 67% and negative predictive value of 100% when compared with the OSLER test. The value of area under the ROC curve was 0.81 (0.62-0.99), p=0.013. In a Bland-Altman plot, most of the latency times differences are in the 95% agreement interval (p=0.05). In addition, the confidence interval of the mean and most of the positive results are above the zero line. The Cohens Kappa coefficient obtained is 0.58 (95% CI 0.29-0.88). CONCLUSION: In this sample of patients, the proposed method detects EDS in a similar way as OSLER test and can be performed in different environments without requiring special infrastructure or expert personnel. |
format | Online Article Text |
id | pubmed-8340892 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Brazilian Association of Sleep and Latin American Federation of
Sleep |
record_format | MEDLINE/PubMed |
spelling | pubmed-83408922021-08-10 Simplified sleep resistance test for daytime sleepiness detection Larrateguy, Luis Darío Pais, Carlos M. Larrateguy, Luis I. Larrateguy, Santiago D. Schlotthauer, Gaston Sleep Sci Short Communications OBJECTIVES: Excessive daytime sleepiness (EDS) is a highly prevalent symptom that increases the risk of traffic accidents and deteriorates the quality of life. The diagnosis of EDS is difficult because of the complex infrastructure that is required. The new test here proposed assesses the ability of a simple test of simplify the detection of daytime sleepiness compared with the OSLER test. MATERIAL AND METHODS: In the new test, during 20 minute subjects were asked to pass a finger by a groove in response to a light emitting diode, inside dark glasses, which was lit for 1s in every three, with headphones that reduce the ambient noise and was compared with the OSLER test on each subject in random order. RESULTS: The proposed method showed a sensitivity of 100% and a specificity of 61%, with a positive predictive value of 67% and negative predictive value of 100% when compared with the OSLER test. The value of area under the ROC curve was 0.81 (0.62-0.99), p=0.013. In a Bland-Altman plot, most of the latency times differences are in the 95% agreement interval (p=0.05). In addition, the confidence interval of the mean and most of the positive results are above the zero line. The Cohens Kappa coefficient obtained is 0.58 (95% CI 0.29-0.88). CONCLUSION: In this sample of patients, the proposed method detects EDS in a similar way as OSLER test and can be performed in different environments without requiring special infrastructure or expert personnel. Brazilian Association of Sleep and Latin American Federation of Sleep 2021 /pmc/articles/PMC8340892/ /pubmed/34381580 http://dx.doi.org/10.5935/1984-0063.20200046 Text en https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Short Communications Larrateguy, Luis Darío Pais, Carlos M. Larrateguy, Luis I. Larrateguy, Santiago D. Schlotthauer, Gaston Simplified sleep resistance test for daytime sleepiness detection |
title | Simplified sleep resistance test for daytime sleepiness
detection |
title_full | Simplified sleep resistance test for daytime sleepiness
detection |
title_fullStr | Simplified sleep resistance test for daytime sleepiness
detection |
title_full_unstemmed | Simplified sleep resistance test for daytime sleepiness
detection |
title_short | Simplified sleep resistance test for daytime sleepiness
detection |
title_sort | simplified sleep resistance test for daytime sleepiness
detection |
topic | Short Communications |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8340892/ https://www.ncbi.nlm.nih.gov/pubmed/34381580 http://dx.doi.org/10.5935/1984-0063.20200046 |
work_keys_str_mv | AT larrateguyluisdario simplifiedsleepresistancetestfordaytimesleepinessdetection AT paiscarlosm simplifiedsleepresistancetestfordaytimesleepinessdetection AT larrateguyluisi simplifiedsleepresistancetestfordaytimesleepinessdetection AT larrateguysantiagod simplifiedsleepresistancetestfordaytimesleepinessdetection AT schlotthauergaston simplifiedsleepresistancetestfordaytimesleepinessdetection |