Use of a non-invasive accelerometric method for diagnosing gastroesophageal reflux in premature infants
OBJECTIVE: To evaluate the clinical usefulness of a non-invasive accelerometric device to diagnose GER in preterm babies. STUDY DESIGN: An accelerometer was taped over the sub-xiphoid process in 110 preterm (GA 29.6 ± 3.3 wk) infants (133 studies). Low frequency, sub-audible signals were captured vi...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group US
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8342305/ https://www.ncbi.nlm.nih.gov/pubmed/33758392 http://dx.doi.org/10.1038/s41372-021-01034-5 |
_version_ | 1783734038327984128 |
---|---|
author | Gewolb, Ira H. Vice, Frank L. |
author_facet | Gewolb, Ira H. Vice, Frank L. |
author_sort | Gewolb, Ira H. |
collection | PubMed |
description | OBJECTIVE: To evaluate the clinical usefulness of a non-invasive accelerometric device to diagnose GER in preterm babies. STUDY DESIGN: An accelerometer was taped over the sub-xiphoid process in 110 preterm (GA 29.6 ± 3.3 wk) infants (133 studies). Low frequency, sub-audible signals were captured via digital recording (sampling rate 200 Hz), then re-sampled (rate = 60 Hz) to create a spectrogram (focused range 0–30 Hz). Mean amplitude in the focused range was calculated. RESULTS: Of 85 studies with simultaneous pH-metry and accelerometry, 18 had concurrent positive and 23 had concurrent negative scores, 42 had negative pH scores when accelerometry was positive (≥1 µV), consistent with non-acid reflux. Eleven infants at high risk of aspiration received surgical interventions. All but 1 had negative pH scores while 10/11 had positive accelerometry. CONCLUSIONS: The non-invasiveness of this accelerometric technique allows for GER screening and for repeated testing to assess efficacy of interventions. |
format | Online Article Text |
id | pubmed-8342305 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Nature Publishing Group US |
record_format | MEDLINE/PubMed |
spelling | pubmed-83423052021-08-20 Use of a non-invasive accelerometric method for diagnosing gastroesophageal reflux in premature infants Gewolb, Ira H. Vice, Frank L. J Perinatol Article OBJECTIVE: To evaluate the clinical usefulness of a non-invasive accelerometric device to diagnose GER in preterm babies. STUDY DESIGN: An accelerometer was taped over the sub-xiphoid process in 110 preterm (GA 29.6 ± 3.3 wk) infants (133 studies). Low frequency, sub-audible signals were captured via digital recording (sampling rate 200 Hz), then re-sampled (rate = 60 Hz) to create a spectrogram (focused range 0–30 Hz). Mean amplitude in the focused range was calculated. RESULTS: Of 85 studies with simultaneous pH-metry and accelerometry, 18 had concurrent positive and 23 had concurrent negative scores, 42 had negative pH scores when accelerometry was positive (≥1 µV), consistent with non-acid reflux. Eleven infants at high risk of aspiration received surgical interventions. All but 1 had negative pH scores while 10/11 had positive accelerometry. CONCLUSIONS: The non-invasiveness of this accelerometric technique allows for GER screening and for repeated testing to assess efficacy of interventions. Nature Publishing Group US 2021-03-23 2021 /pmc/articles/PMC8342305/ /pubmed/33758392 http://dx.doi.org/10.1038/s41372-021-01034-5 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Gewolb, Ira H. Vice, Frank L. Use of a non-invasive accelerometric method for diagnosing gastroesophageal reflux in premature infants |
title | Use of a non-invasive accelerometric method for diagnosing gastroesophageal reflux in premature infants |
title_full | Use of a non-invasive accelerometric method for diagnosing gastroesophageal reflux in premature infants |
title_fullStr | Use of a non-invasive accelerometric method for diagnosing gastroesophageal reflux in premature infants |
title_full_unstemmed | Use of a non-invasive accelerometric method for diagnosing gastroesophageal reflux in premature infants |
title_short | Use of a non-invasive accelerometric method for diagnosing gastroesophageal reflux in premature infants |
title_sort | use of a non-invasive accelerometric method for diagnosing gastroesophageal reflux in premature infants |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8342305/ https://www.ncbi.nlm.nih.gov/pubmed/33758392 http://dx.doi.org/10.1038/s41372-021-01034-5 |
work_keys_str_mv | AT gewolbirah useofanoninvasiveaccelerometricmethodfordiagnosinggastroesophagealrefluxinprematureinfants AT vicefrankl useofanoninvasiveaccelerometricmethodfordiagnosinggastroesophagealrefluxinprematureinfants |