Early and Middle-Term Results and Anticoagulation Strategy after Left Atrial Appendage Exclusion Using an Epicardial Clip Device

Objective: The present study aimed to evaluate short- and middle-term results and postoperative anticoagulation of left atrial appendage (LAA) exclusion with an epicardial clip device. Materials and Methods: From September 2017 to August 2019, 102 patients at our institution underwent epicardial LAA...

Descripción completa

Detalles Bibliográficos
Autores principales: Yoshimoto, Akihiro, Suematsu, Yoshihiro, Kurahashi, Kanan, Kaneko, Hiroyuki, Arima, Daisuke, Nishi, Satoshi
Formato: Online Artículo Texto
Lenguaje:English
Publicado: The Editorial Committee of Annals of Thoracic and Cardiovascular Surgery 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8343034/
https://www.ncbi.nlm.nih.gov/pubmed/33208590
http://dx.doi.org/10.5761/atcs.oa.20-00204
_version_ 1783734192493821952
author Yoshimoto, Akihiro
Suematsu, Yoshihiro
Kurahashi, Kanan
Kaneko, Hiroyuki
Arima, Daisuke
Nishi, Satoshi
author_facet Yoshimoto, Akihiro
Suematsu, Yoshihiro
Kurahashi, Kanan
Kaneko, Hiroyuki
Arima, Daisuke
Nishi, Satoshi
author_sort Yoshimoto, Akihiro
collection PubMed
description Objective: The present study aimed to evaluate short- and middle-term results and postoperative anticoagulation of left atrial appendage (LAA) exclusion with an epicardial clip device. Materials and Methods: From September 2017 to August 2019, 102 patients at our institution underwent epicardial LAA exclusion using the AtriClip device. Anticoagulation therapy was resumed in the very early postoperative period and continued for at least three months after surgery. The patients’ data were obtained by reviewing their medical records retrospectively. Results: The mean and median durations of follow-up was 510 ± 184 days and 482 days (range, 216–938 days), respectively. Successful LAA exclusion was confirmed in all but one patient. No device-related complications occurred during surgery. Postoperative computed tomography (CT) findings revealed no migration or displacement of the clips in any patient; however, small clots were observed at the LAA stump in seven patients. Stroke-free rate during the follow-up period was 98.9%. Conclusion: LAA exclusion using the AtriClip device was a feasible treatment method in terms of its early and middle-term safety and efficacy. In addition, our postoperative anticoagulation strategy could be optimal for maximizing the procedure’s merits, although further studies, involving a larger number of patients and longer duration of follow-up, are needed.
format Online
Article
Text
id pubmed-8343034
institution National Center for Biotechnology Information
language English
publishDate 2020
publisher The Editorial Committee of Annals of Thoracic and Cardiovascular Surgery
record_format MEDLINE/PubMed
spelling pubmed-83430342021-08-06 Early and Middle-Term Results and Anticoagulation Strategy after Left Atrial Appendage Exclusion Using an Epicardial Clip Device Yoshimoto, Akihiro Suematsu, Yoshihiro Kurahashi, Kanan Kaneko, Hiroyuki Arima, Daisuke Nishi, Satoshi Ann Thorac Cardiovasc Surg Original Article Objective: The present study aimed to evaluate short- and middle-term results and postoperative anticoagulation of left atrial appendage (LAA) exclusion with an epicardial clip device. Materials and Methods: From September 2017 to August 2019, 102 patients at our institution underwent epicardial LAA exclusion using the AtriClip device. Anticoagulation therapy was resumed in the very early postoperative period and continued for at least three months after surgery. The patients’ data were obtained by reviewing their medical records retrospectively. Results: The mean and median durations of follow-up was 510 ± 184 days and 482 days (range, 216–938 days), respectively. Successful LAA exclusion was confirmed in all but one patient. No device-related complications occurred during surgery. Postoperative computed tomography (CT) findings revealed no migration or displacement of the clips in any patient; however, small clots were observed at the LAA stump in seven patients. Stroke-free rate during the follow-up period was 98.9%. Conclusion: LAA exclusion using the AtriClip device was a feasible treatment method in terms of its early and middle-term safety and efficacy. In addition, our postoperative anticoagulation strategy could be optimal for maximizing the procedure’s merits, although further studies, involving a larger number of patients and longer duration of follow-up, are needed. The Editorial Committee of Annals of Thoracic and Cardiovascular Surgery 2020-11-19 2021 /pmc/articles/PMC8343034/ /pubmed/33208590 http://dx.doi.org/10.5761/atcs.oa.20-00204 Text en ©2021 Annals of Thoracic and Cardiovascular Surgery https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-NonDerivatives International License (https://creativecommons.org/licenses/by-nc-nd/4.0/)
spellingShingle Original Article
Yoshimoto, Akihiro
Suematsu, Yoshihiro
Kurahashi, Kanan
Kaneko, Hiroyuki
Arima, Daisuke
Nishi, Satoshi
Early and Middle-Term Results and Anticoagulation Strategy after Left Atrial Appendage Exclusion Using an Epicardial Clip Device
title Early and Middle-Term Results and Anticoagulation Strategy after Left Atrial Appendage Exclusion Using an Epicardial Clip Device
title_full Early and Middle-Term Results and Anticoagulation Strategy after Left Atrial Appendage Exclusion Using an Epicardial Clip Device
title_fullStr Early and Middle-Term Results and Anticoagulation Strategy after Left Atrial Appendage Exclusion Using an Epicardial Clip Device
title_full_unstemmed Early and Middle-Term Results and Anticoagulation Strategy after Left Atrial Appendage Exclusion Using an Epicardial Clip Device
title_short Early and Middle-Term Results and Anticoagulation Strategy after Left Atrial Appendage Exclusion Using an Epicardial Clip Device
title_sort early and middle-term results and anticoagulation strategy after left atrial appendage exclusion using an epicardial clip device
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8343034/
https://www.ncbi.nlm.nih.gov/pubmed/33208590
http://dx.doi.org/10.5761/atcs.oa.20-00204
work_keys_str_mv AT yoshimotoakihiro earlyandmiddletermresultsandanticoagulationstrategyafterleftatrialappendageexclusionusinganepicardialclipdevice
AT suematsuyoshihiro earlyandmiddletermresultsandanticoagulationstrategyafterleftatrialappendageexclusionusinganepicardialclipdevice
AT kurahashikanan earlyandmiddletermresultsandanticoagulationstrategyafterleftatrialappendageexclusionusinganepicardialclipdevice
AT kanekohiroyuki earlyandmiddletermresultsandanticoagulationstrategyafterleftatrialappendageexclusionusinganepicardialclipdevice
AT arimadaisuke earlyandmiddletermresultsandanticoagulationstrategyafterleftatrialappendageexclusionusinganepicardialclipdevice
AT nishisatoshi earlyandmiddletermresultsandanticoagulationstrategyafterleftatrialappendageexclusionusinganepicardialclipdevice