Cargando…

Effect of prone positioning on oxygenation and static respiratory system compliance in COVID-19 ARDS vs. non-COVID ARDS

BACKGROUND: Prone positioning is recommended for patients with moderate-to-severe acute respiratory distress syndrome (ARDS) receiving mechanical ventilation. While the debate continues as to whether COVID-19 ARDS is clinically different from non-COVID ARDS, there is little data on whether the physi...

Descripción completa

Detalles Bibliográficos
Autores principales: Park, Jimyung, Lee, Hong Yeul, Lee, Jinwoo, Lee, Sang-Min
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8343350/
https://www.ncbi.nlm.nih.gov/pubmed/34362368
http://dx.doi.org/10.1186/s12931-021-01819-4
_version_ 1783734269620781056
author Park, Jimyung
Lee, Hong Yeul
Lee, Jinwoo
Lee, Sang-Min
author_facet Park, Jimyung
Lee, Hong Yeul
Lee, Jinwoo
Lee, Sang-Min
author_sort Park, Jimyung
collection PubMed
description BACKGROUND: Prone positioning is recommended for patients with moderate-to-severe acute respiratory distress syndrome (ARDS) receiving mechanical ventilation. While the debate continues as to whether COVID-19 ARDS is clinically different from non-COVID ARDS, there is little data on whether the physiological effects of prone positioning differ between the two conditions. We aimed to compare the physiological effect of prone positioning between patients with COVID-19 ARDS and those with non-COVID ARDS. METHODS: We retrospectively compared 23 patients with COVID-19 ARDS and 145 patients with non-COVID ARDS treated using prone positioning while on mechanical ventilation. Changes in PaO(2)/FiO(2) ratio and static respiratory system compliance (Crs) after the first session of prone positioning were compared between the two groups: first, using all patients with non-COVID ARDS, and second, using subgroups of patients with non-COVID ARDS matched 1:1 with patients with COVID-19 ARDS for baseline PaO(2)/FiO(2) ratio and static Crs. We also evaluated whether the response to the first prone positioning session was associated with the clinical outcome. RESULTS: When compared with the entire group of patients with non-COVID ARDS, patients with COVID-19 ARDS showed more pronounced improvement in PaO(2)/FiO(2) ratio [adjusted difference 39.3 (95% CI 5.2–73.5) mmHg] and static Crs [adjusted difference 3.4 (95% CI 1.1–5.6) mL/cmH(2)O]. However, these between-group differences were not significant when the matched samples (either PaO(2)/FiO(2)-matched or compliance-matched) were analyzed. Patients who successfully discontinued mechanical ventilation showed more remarkable improvement in PaO(2)/FiO(2) ratio [median 112 (IQR 85–144) vs. 35 (IQR 6–52) mmHg, P = 0.003] and static compliance [median 5.7 (IQR 3.3–7.7) vs. − 1.0 (IQR − 3.7–3.0) mL/cmH(2)O, P = 0.006] after prone positioning compared with patients who did not. The association between oxygenation and Crs responses to prone positioning and clinical outcome was also evident in the adjusted competing risk regression. CONCLUSIONS: In patients with COVID-19 ARDS, prone positioning was as effective in improving respiratory physiology as in patients with non-COVID ARDS. Thus, it should be actively considered as a therapeutic option. The physiological response to the first session of prone positioning was predictive of the clinical outcome of patients with COVID-19 ARDS. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12931-021-01819-4.
format Online
Article
Text
id pubmed-8343350
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-83433502021-08-06 Effect of prone positioning on oxygenation and static respiratory system compliance in COVID-19 ARDS vs. non-COVID ARDS Park, Jimyung Lee, Hong Yeul Lee, Jinwoo Lee, Sang-Min Respir Res Research BACKGROUND: Prone positioning is recommended for patients with moderate-to-severe acute respiratory distress syndrome (ARDS) receiving mechanical ventilation. While the debate continues as to whether COVID-19 ARDS is clinically different from non-COVID ARDS, there is little data on whether the physiological effects of prone positioning differ between the two conditions. We aimed to compare the physiological effect of prone positioning between patients with COVID-19 ARDS and those with non-COVID ARDS. METHODS: We retrospectively compared 23 patients with COVID-19 ARDS and 145 patients with non-COVID ARDS treated using prone positioning while on mechanical ventilation. Changes in PaO(2)/FiO(2) ratio and static respiratory system compliance (Crs) after the first session of prone positioning were compared between the two groups: first, using all patients with non-COVID ARDS, and second, using subgroups of patients with non-COVID ARDS matched 1:1 with patients with COVID-19 ARDS for baseline PaO(2)/FiO(2) ratio and static Crs. We also evaluated whether the response to the first prone positioning session was associated with the clinical outcome. RESULTS: When compared with the entire group of patients with non-COVID ARDS, patients with COVID-19 ARDS showed more pronounced improvement in PaO(2)/FiO(2) ratio [adjusted difference 39.3 (95% CI 5.2–73.5) mmHg] and static Crs [adjusted difference 3.4 (95% CI 1.1–5.6) mL/cmH(2)O]. However, these between-group differences were not significant when the matched samples (either PaO(2)/FiO(2)-matched or compliance-matched) were analyzed. Patients who successfully discontinued mechanical ventilation showed more remarkable improvement in PaO(2)/FiO(2) ratio [median 112 (IQR 85–144) vs. 35 (IQR 6–52) mmHg, P = 0.003] and static compliance [median 5.7 (IQR 3.3–7.7) vs. − 1.0 (IQR − 3.7–3.0) mL/cmH(2)O, P = 0.006] after prone positioning compared with patients who did not. The association between oxygenation and Crs responses to prone positioning and clinical outcome was also evident in the adjusted competing risk regression. CONCLUSIONS: In patients with COVID-19 ARDS, prone positioning was as effective in improving respiratory physiology as in patients with non-COVID ARDS. Thus, it should be actively considered as a therapeutic option. The physiological response to the first session of prone positioning was predictive of the clinical outcome of patients with COVID-19 ARDS. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12931-021-01819-4. BioMed Central 2021-08-06 2021 /pmc/articles/PMC8343350/ /pubmed/34362368 http://dx.doi.org/10.1186/s12931-021-01819-4 Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Park, Jimyung
Lee, Hong Yeul
Lee, Jinwoo
Lee, Sang-Min
Effect of prone positioning on oxygenation and static respiratory system compliance in COVID-19 ARDS vs. non-COVID ARDS
title Effect of prone positioning on oxygenation and static respiratory system compliance in COVID-19 ARDS vs. non-COVID ARDS
title_full Effect of prone positioning on oxygenation and static respiratory system compliance in COVID-19 ARDS vs. non-COVID ARDS
title_fullStr Effect of prone positioning on oxygenation and static respiratory system compliance in COVID-19 ARDS vs. non-COVID ARDS
title_full_unstemmed Effect of prone positioning on oxygenation and static respiratory system compliance in COVID-19 ARDS vs. non-COVID ARDS
title_short Effect of prone positioning on oxygenation and static respiratory system compliance in COVID-19 ARDS vs. non-COVID ARDS
title_sort effect of prone positioning on oxygenation and static respiratory system compliance in covid-19 ards vs. non-covid ards
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8343350/
https://www.ncbi.nlm.nih.gov/pubmed/34362368
http://dx.doi.org/10.1186/s12931-021-01819-4
work_keys_str_mv AT parkjimyung effectofpronepositioningonoxygenationandstaticrespiratorysystemcomplianceincovid19ardsvsnoncovidards
AT leehongyeul effectofpronepositioningonoxygenationandstaticrespiratorysystemcomplianceincovid19ardsvsnoncovidards
AT leejinwoo effectofpronepositioningonoxygenationandstaticrespiratorysystemcomplianceincovid19ardsvsnoncovidards
AT leesangmin effectofpronepositioningonoxygenationandstaticrespiratorysystemcomplianceincovid19ardsvsnoncovidards