Cargando…
Cryogenic Blackbody Calibrations at the National Institute of Standards and Technology Low Background Infrared Calibration Facility
The Low Background Infrared Calibration Facility (LBIR) at the National Institute of Standards and Technology has been in operation for calibration measurements of the radiant power emitted from infrared radiation (IR) sources, such as cryogenic blackbodies, for more than 2 years. The IR sources are...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
[Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology
1994
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8345260/ https://www.ncbi.nlm.nih.gov/pubmed/37404363 http://dx.doi.org/10.6028/jres.099.008 |
_version_ | 1783734587649687552 |
---|---|
author | Datla, R. U. Croarkin, M. C. Parr, A. C. |
author_facet | Datla, R. U. Croarkin, M. C. Parr, A. C. |
author_sort | Datla, R. U. |
collection | PubMed |
description | The Low Background Infrared Calibration Facility (LBIR) at the National Institute of Standards and Technology has been in operation for calibration measurements of the radiant power emitted from infrared radiation (IR) sources, such as cryogenic blackbodies, for more than 2 years. The IR sources are sent to NIST by customers from industry, government, and university laboratories. An absolute cryogenic radiometer is used as the standard detector to measure the total radiant power at its aperture. The low background is provided by a closed cycle helium refrigeration system that maintains the inner parts of the calibration chamber at 20 K. The radiance temperature of the blackbody is deduced from the measured power and compared with the blackbody temperature sensor data. The calibration procedures and data analysis are illustrated using the measurements of a typical blackbody. |
format | Online Article Text |
id | pubmed-8345260 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 1994 |
publisher | [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology |
record_format | MEDLINE/PubMed |
spelling | pubmed-83452602023-07-03 Cryogenic Blackbody Calibrations at the National Institute of Standards and Technology Low Background Infrared Calibration Facility Datla, R. U. Croarkin, M. C. Parr, A. C. J Res Natl Inst Stand Technol Article The Low Background Infrared Calibration Facility (LBIR) at the National Institute of Standards and Technology has been in operation for calibration measurements of the radiant power emitted from infrared radiation (IR) sources, such as cryogenic blackbodies, for more than 2 years. The IR sources are sent to NIST by customers from industry, government, and university laboratories. An absolute cryogenic radiometer is used as the standard detector to measure the total radiant power at its aperture. The low background is provided by a closed cycle helium refrigeration system that maintains the inner parts of the calibration chamber at 20 K. The radiance temperature of the blackbody is deduced from the measured power and compared with the blackbody temperature sensor data. The calibration procedures and data analysis are illustrated using the measurements of a typical blackbody. [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 1994 /pmc/articles/PMC8345260/ /pubmed/37404363 http://dx.doi.org/10.6028/jres.099.008 Text en https://creativecommons.org/publicdomain/zero/1.0/The Journal of Research of the National Institute of Standards and Technology is a publication of the U.S. Government. The papers are in the public domain and are not subject to copyright in the United States. Articles from J Res may contain photographs or illustrations copyrighted by other commercial organizations or individuals that may not be used without obtaining prior approval from the holder of the copyright. |
spellingShingle | Article Datla, R. U. Croarkin, M. C. Parr, A. C. Cryogenic Blackbody Calibrations at the National Institute of Standards and Technology Low Background Infrared Calibration Facility |
title | Cryogenic Blackbody Calibrations at the National Institute of Standards and Technology Low Background Infrared Calibration Facility |
title_full | Cryogenic Blackbody Calibrations at the National Institute of Standards and Technology Low Background Infrared Calibration Facility |
title_fullStr | Cryogenic Blackbody Calibrations at the National Institute of Standards and Technology Low Background Infrared Calibration Facility |
title_full_unstemmed | Cryogenic Blackbody Calibrations at the National Institute of Standards and Technology Low Background Infrared Calibration Facility |
title_short | Cryogenic Blackbody Calibrations at the National Institute of Standards and Technology Low Background Infrared Calibration Facility |
title_sort | cryogenic blackbody calibrations at the national institute of standards and technology low background infrared calibration facility |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8345260/ https://www.ncbi.nlm.nih.gov/pubmed/37404363 http://dx.doi.org/10.6028/jres.099.008 |
work_keys_str_mv | AT datlaru cryogenicblackbodycalibrationsatthenationalinstituteofstandardsandtechnologylowbackgroundinfraredcalibrationfacility AT croarkinmc cryogenicblackbodycalibrationsatthenationalinstituteofstandardsandtechnologylowbackgroundinfraredcalibrationfacility AT parrac cryogenicblackbodycalibrationsatthenationalinstituteofstandardsandtechnologylowbackgroundinfraredcalibrationfacility |