A dc Method for the Absolute Determination of Conductivities of the Primary Standard KCl Solutions from 0 °C to 50 °C
A new method for the absolute determination of electrolytic conductivity based on direct current and Potentiometric measurements is described. The unique design of the cell uses a removable center section whose length and cross-sectional area are accurately known. Two pairs of matched Ag, AgCl elect...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
[Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology
1994
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8345273/ https://www.ncbi.nlm.nih.gov/pubmed/37405080 http://dx.doi.org/10.6028/jres.099.019 |
_version_ | 1783734589171171328 |
---|---|
author | Wu, Y. C. Koch, W. F. Feng, D. Holland, L. A. Juhasz, E. Arvay, E. Tomek, A. |
author_facet | Wu, Y. C. Koch, W. F. Feng, D. Holland, L. A. Juhasz, E. Arvay, E. Tomek, A. |
author_sort | Wu, Y. C. |
collection | PubMed |
description | A new method for the absolute determination of electrolytic conductivity based on direct current and Potentiometric measurements is described. The unique design of the cell uses a removable center section whose length and cross-sectional area are accurately known. Two pairs of matched Ag, AgCl electrodes are used in a four terminal mode of resistance measurement. Measurements of the electrolytic conductivity of primary standard potassium chloride solution using [his novel dc conductance cell are compared with the currently adopted IUPAC and OIML recommendations. In addition, measurements have heen made of the electrolytic conductivity of a solution of potassium chloride having a molality of 1 mol/kg (mole KCl per kilogram H(2)O). The values so obtained over the temperature range of 0 °C to 50 °C are recommended as the new primary standards for electrolytic conductivity. |
format | Online Article Text |
id | pubmed-8345273 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 1994 |
publisher | [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology |
record_format | MEDLINE/PubMed |
spelling | pubmed-83452732023-07-03 A dc Method for the Absolute Determination of Conductivities of the Primary Standard KCl Solutions from 0 °C to 50 °C Wu, Y. C. Koch, W. F. Feng, D. Holland, L. A. Juhasz, E. Arvay, E. Tomek, A. J Res Natl Inst Stand Technol Article A new method for the absolute determination of electrolytic conductivity based on direct current and Potentiometric measurements is described. The unique design of the cell uses a removable center section whose length and cross-sectional area are accurately known. Two pairs of matched Ag, AgCl electrodes are used in a four terminal mode of resistance measurement. Measurements of the electrolytic conductivity of primary standard potassium chloride solution using [his novel dc conductance cell are compared with the currently adopted IUPAC and OIML recommendations. In addition, measurements have heen made of the electrolytic conductivity of a solution of potassium chloride having a molality of 1 mol/kg (mole KCl per kilogram H(2)O). The values so obtained over the temperature range of 0 °C to 50 °C are recommended as the new primary standards for electrolytic conductivity. [Gaithersburg, MD] : U.S. Dept. of Commerce, National Institute of Standards and Technology 1994 /pmc/articles/PMC8345273/ /pubmed/37405080 http://dx.doi.org/10.6028/jres.099.019 Text en https://creativecommons.org/publicdomain/zero/1.0/The Journal of Research of the National Institute of Standards and Technology is a publication of the U.S. Government. The papers are in the public domain and are not subject to copyright in the United States. Articles from J Res may contain photographs or illustrations copyrighted by other commercial organizations or individuals that may not be used without obtaining prior approval from the holder of the copyright. |
spellingShingle | Article Wu, Y. C. Koch, W. F. Feng, D. Holland, L. A. Juhasz, E. Arvay, E. Tomek, A. A dc Method for the Absolute Determination of Conductivities of the Primary Standard KCl Solutions from 0 °C to 50 °C |
title | A dc Method for the Absolute Determination of Conductivities of the Primary Standard KCl Solutions from 0 °C to 50 °C |
title_full | A dc Method for the Absolute Determination of Conductivities of the Primary Standard KCl Solutions from 0 °C to 50 °C |
title_fullStr | A dc Method for the Absolute Determination of Conductivities of the Primary Standard KCl Solutions from 0 °C to 50 °C |
title_full_unstemmed | A dc Method for the Absolute Determination of Conductivities of the Primary Standard KCl Solutions from 0 °C to 50 °C |
title_short | A dc Method for the Absolute Determination of Conductivities of the Primary Standard KCl Solutions from 0 °C to 50 °C |
title_sort | dc method for the absolute determination of conductivities of the primary standard kcl solutions from 0 °c to 50 °c |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8345273/ https://www.ncbi.nlm.nih.gov/pubmed/37405080 http://dx.doi.org/10.6028/jres.099.019 |
work_keys_str_mv | AT wuyc adcmethodfortheabsolutedeterminationofconductivitiesoftheprimarystandardkclsolutionsfrom0cto50c AT kochwf adcmethodfortheabsolutedeterminationofconductivitiesoftheprimarystandardkclsolutionsfrom0cto50c AT fengd adcmethodfortheabsolutedeterminationofconductivitiesoftheprimarystandardkclsolutionsfrom0cto50c AT hollandla adcmethodfortheabsolutedeterminationofconductivitiesoftheprimarystandardkclsolutionsfrom0cto50c AT juhasze adcmethodfortheabsolutedeterminationofconductivitiesoftheprimarystandardkclsolutionsfrom0cto50c AT arvaye adcmethodfortheabsolutedeterminationofconductivitiesoftheprimarystandardkclsolutionsfrom0cto50c AT tomeka adcmethodfortheabsolutedeterminationofconductivitiesoftheprimarystandardkclsolutionsfrom0cto50c AT wuyc dcmethodfortheabsolutedeterminationofconductivitiesoftheprimarystandardkclsolutionsfrom0cto50c AT kochwf dcmethodfortheabsolutedeterminationofconductivitiesoftheprimarystandardkclsolutionsfrom0cto50c AT fengd dcmethodfortheabsolutedeterminationofconductivitiesoftheprimarystandardkclsolutionsfrom0cto50c AT hollandla dcmethodfortheabsolutedeterminationofconductivitiesoftheprimarystandardkclsolutionsfrom0cto50c AT juhasze dcmethodfortheabsolutedeterminationofconductivitiesoftheprimarystandardkclsolutionsfrom0cto50c AT arvaye dcmethodfortheabsolutedeterminationofconductivitiesoftheprimarystandardkclsolutionsfrom0cto50c AT tomeka dcmethodfortheabsolutedeterminationofconductivitiesoftheprimarystandardkclsolutionsfrom0cto50c |