Cargando…

Customized eye modeling for optical quality assessment in myopic femto-LASIK surgery

Refractive surgery is recognized as an effective method for myopia treatment, but it can induce night vision disturbances such as glare. We present an eye modeling method for the optical quality assessment in response to the structural changes in the eyes by femto-LASIK surgery. Customized eye model...

Descripción completa

Detalles Bibliográficos
Autores principales: Lan, Gongpu, Zeng, Jun, Li, Wenjie, Ma, Guoqin, Shi, Qun, Shi, Yue, Wang, Yicheng, Xu, Jingjiang, Huang, Yanping, Qin, Jia, Feng, Jinping, Tan, Haishu, An, Lin, Wei, Xunbin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8346559/
https://www.ncbi.nlm.nih.gov/pubmed/34362982
http://dx.doi.org/10.1038/s41598-021-95730-z
_version_ 1783734901725462528
author Lan, Gongpu
Zeng, Jun
Li, Wenjie
Ma, Guoqin
Shi, Qun
Shi, Yue
Wang, Yicheng
Xu, Jingjiang
Huang, Yanping
Qin, Jia
Feng, Jinping
Tan, Haishu
An, Lin
Wei, Xunbin
author_facet Lan, Gongpu
Zeng, Jun
Li, Wenjie
Ma, Guoqin
Shi, Qun
Shi, Yue
Wang, Yicheng
Xu, Jingjiang
Huang, Yanping
Qin, Jia
Feng, Jinping
Tan, Haishu
An, Lin
Wei, Xunbin
author_sort Lan, Gongpu
collection PubMed
description Refractive surgery is recognized as an effective method for myopia treatment, but it can induce night vision disturbances such as glare. We present an eye modeling method for the optical quality assessment in response to the structural changes in the eyes by femto-LASIK surgery. Customized eye models were built from the measurements of 134 right eyes pre- and post-operatively. Optical performance was evaluated using spot diagrams, point spread functions (PSFs), modulation transfer functions (MTFs), and chromatic aberrations at various fields (0°–30°), different pupil diameters (2–6 mm), and initial myopias (− 1.25 to − 10.5 D). Pupil size and initial myopia are the two major factors that affect visual performance of post-operative eyes. The results of spot diagrams, PSFs, and MTFs indicated that post-operative visual performance deteriorated as the visual field and pupil size increased, and it was significantly influenced by initial myopia. Post-operative chromatic aberrations were also affected by initial myopia. As pupil size increased, the post-operative longitudinal chromatic aberrations tended to decrease slightly, while the transverse chromatic aberrations remained similar. The use of eye modeling for refractive surgery assessment could possibly provide a more personalized surgical approach, could improve the prediction accuracy of refractive surgery outcomes, and promote the invention and development of better surgical methods.
format Online
Article
Text
id pubmed-8346559
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-83465592021-08-10 Customized eye modeling for optical quality assessment in myopic femto-LASIK surgery Lan, Gongpu Zeng, Jun Li, Wenjie Ma, Guoqin Shi, Qun Shi, Yue Wang, Yicheng Xu, Jingjiang Huang, Yanping Qin, Jia Feng, Jinping Tan, Haishu An, Lin Wei, Xunbin Sci Rep Article Refractive surgery is recognized as an effective method for myopia treatment, but it can induce night vision disturbances such as glare. We present an eye modeling method for the optical quality assessment in response to the structural changes in the eyes by femto-LASIK surgery. Customized eye models were built from the measurements of 134 right eyes pre- and post-operatively. Optical performance was evaluated using spot diagrams, point spread functions (PSFs), modulation transfer functions (MTFs), and chromatic aberrations at various fields (0°–30°), different pupil diameters (2–6 mm), and initial myopias (− 1.25 to − 10.5 D). Pupil size and initial myopia are the two major factors that affect visual performance of post-operative eyes. The results of spot diagrams, PSFs, and MTFs indicated that post-operative visual performance deteriorated as the visual field and pupil size increased, and it was significantly influenced by initial myopia. Post-operative chromatic aberrations were also affected by initial myopia. As pupil size increased, the post-operative longitudinal chromatic aberrations tended to decrease slightly, while the transverse chromatic aberrations remained similar. The use of eye modeling for refractive surgery assessment could possibly provide a more personalized surgical approach, could improve the prediction accuracy of refractive surgery outcomes, and promote the invention and development of better surgical methods. Nature Publishing Group UK 2021-08-06 /pmc/articles/PMC8346559/ /pubmed/34362982 http://dx.doi.org/10.1038/s41598-021-95730-z Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Lan, Gongpu
Zeng, Jun
Li, Wenjie
Ma, Guoqin
Shi, Qun
Shi, Yue
Wang, Yicheng
Xu, Jingjiang
Huang, Yanping
Qin, Jia
Feng, Jinping
Tan, Haishu
An, Lin
Wei, Xunbin
Customized eye modeling for optical quality assessment in myopic femto-LASIK surgery
title Customized eye modeling for optical quality assessment in myopic femto-LASIK surgery
title_full Customized eye modeling for optical quality assessment in myopic femto-LASIK surgery
title_fullStr Customized eye modeling for optical quality assessment in myopic femto-LASIK surgery
title_full_unstemmed Customized eye modeling for optical quality assessment in myopic femto-LASIK surgery
title_short Customized eye modeling for optical quality assessment in myopic femto-LASIK surgery
title_sort customized eye modeling for optical quality assessment in myopic femto-lasik surgery
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8346559/
https://www.ncbi.nlm.nih.gov/pubmed/34362982
http://dx.doi.org/10.1038/s41598-021-95730-z
work_keys_str_mv AT langongpu customizedeyemodelingforopticalqualityassessmentinmyopicfemtolasiksurgery
AT zengjun customizedeyemodelingforopticalqualityassessmentinmyopicfemtolasiksurgery
AT liwenjie customizedeyemodelingforopticalqualityassessmentinmyopicfemtolasiksurgery
AT maguoqin customizedeyemodelingforopticalqualityassessmentinmyopicfemtolasiksurgery
AT shiqun customizedeyemodelingforopticalqualityassessmentinmyopicfemtolasiksurgery
AT shiyue customizedeyemodelingforopticalqualityassessmentinmyopicfemtolasiksurgery
AT wangyicheng customizedeyemodelingforopticalqualityassessmentinmyopicfemtolasiksurgery
AT xujingjiang customizedeyemodelingforopticalqualityassessmentinmyopicfemtolasiksurgery
AT huangyanping customizedeyemodelingforopticalqualityassessmentinmyopicfemtolasiksurgery
AT qinjia customizedeyemodelingforopticalqualityassessmentinmyopicfemtolasiksurgery
AT fengjinping customizedeyemodelingforopticalqualityassessmentinmyopicfemtolasiksurgery
AT tanhaishu customizedeyemodelingforopticalqualityassessmentinmyopicfemtolasiksurgery
AT anlin customizedeyemodelingforopticalqualityassessmentinmyopicfemtolasiksurgery
AT weixunbin customizedeyemodelingforopticalqualityassessmentinmyopicfemtolasiksurgery