Cargando…
Customized eye modeling for optical quality assessment in myopic femto-LASIK surgery
Refractive surgery is recognized as an effective method for myopia treatment, but it can induce night vision disturbances such as glare. We present an eye modeling method for the optical quality assessment in response to the structural changes in the eyes by femto-LASIK surgery. Customized eye model...
Autores principales: | , , , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8346559/ https://www.ncbi.nlm.nih.gov/pubmed/34362982 http://dx.doi.org/10.1038/s41598-021-95730-z |
_version_ | 1783734901725462528 |
---|---|
author | Lan, Gongpu Zeng, Jun Li, Wenjie Ma, Guoqin Shi, Qun Shi, Yue Wang, Yicheng Xu, Jingjiang Huang, Yanping Qin, Jia Feng, Jinping Tan, Haishu An, Lin Wei, Xunbin |
author_facet | Lan, Gongpu Zeng, Jun Li, Wenjie Ma, Guoqin Shi, Qun Shi, Yue Wang, Yicheng Xu, Jingjiang Huang, Yanping Qin, Jia Feng, Jinping Tan, Haishu An, Lin Wei, Xunbin |
author_sort | Lan, Gongpu |
collection | PubMed |
description | Refractive surgery is recognized as an effective method for myopia treatment, but it can induce night vision disturbances such as glare. We present an eye modeling method for the optical quality assessment in response to the structural changes in the eyes by femto-LASIK surgery. Customized eye models were built from the measurements of 134 right eyes pre- and post-operatively. Optical performance was evaluated using spot diagrams, point spread functions (PSFs), modulation transfer functions (MTFs), and chromatic aberrations at various fields (0°–30°), different pupil diameters (2–6 mm), and initial myopias (− 1.25 to − 10.5 D). Pupil size and initial myopia are the two major factors that affect visual performance of post-operative eyes. The results of spot diagrams, PSFs, and MTFs indicated that post-operative visual performance deteriorated as the visual field and pupil size increased, and it was significantly influenced by initial myopia. Post-operative chromatic aberrations were also affected by initial myopia. As pupil size increased, the post-operative longitudinal chromatic aberrations tended to decrease slightly, while the transverse chromatic aberrations remained similar. The use of eye modeling for refractive surgery assessment could possibly provide a more personalized surgical approach, could improve the prediction accuracy of refractive surgery outcomes, and promote the invention and development of better surgical methods. |
format | Online Article Text |
id | pubmed-8346559 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Nature Publishing Group UK |
record_format | MEDLINE/PubMed |
spelling | pubmed-83465592021-08-10 Customized eye modeling for optical quality assessment in myopic femto-LASIK surgery Lan, Gongpu Zeng, Jun Li, Wenjie Ma, Guoqin Shi, Qun Shi, Yue Wang, Yicheng Xu, Jingjiang Huang, Yanping Qin, Jia Feng, Jinping Tan, Haishu An, Lin Wei, Xunbin Sci Rep Article Refractive surgery is recognized as an effective method for myopia treatment, but it can induce night vision disturbances such as glare. We present an eye modeling method for the optical quality assessment in response to the structural changes in the eyes by femto-LASIK surgery. Customized eye models were built from the measurements of 134 right eyes pre- and post-operatively. Optical performance was evaluated using spot diagrams, point spread functions (PSFs), modulation transfer functions (MTFs), and chromatic aberrations at various fields (0°–30°), different pupil diameters (2–6 mm), and initial myopias (− 1.25 to − 10.5 D). Pupil size and initial myopia are the two major factors that affect visual performance of post-operative eyes. The results of spot diagrams, PSFs, and MTFs indicated that post-operative visual performance deteriorated as the visual field and pupil size increased, and it was significantly influenced by initial myopia. Post-operative chromatic aberrations were also affected by initial myopia. As pupil size increased, the post-operative longitudinal chromatic aberrations tended to decrease slightly, while the transverse chromatic aberrations remained similar. The use of eye modeling for refractive surgery assessment could possibly provide a more personalized surgical approach, could improve the prediction accuracy of refractive surgery outcomes, and promote the invention and development of better surgical methods. Nature Publishing Group UK 2021-08-06 /pmc/articles/PMC8346559/ /pubmed/34362982 http://dx.doi.org/10.1038/s41598-021-95730-z Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . |
spellingShingle | Article Lan, Gongpu Zeng, Jun Li, Wenjie Ma, Guoqin Shi, Qun Shi, Yue Wang, Yicheng Xu, Jingjiang Huang, Yanping Qin, Jia Feng, Jinping Tan, Haishu An, Lin Wei, Xunbin Customized eye modeling for optical quality assessment in myopic femto-LASIK surgery |
title | Customized eye modeling for optical quality assessment in myopic femto-LASIK surgery |
title_full | Customized eye modeling for optical quality assessment in myopic femto-LASIK surgery |
title_fullStr | Customized eye modeling for optical quality assessment in myopic femto-LASIK surgery |
title_full_unstemmed | Customized eye modeling for optical quality assessment in myopic femto-LASIK surgery |
title_short | Customized eye modeling for optical quality assessment in myopic femto-LASIK surgery |
title_sort | customized eye modeling for optical quality assessment in myopic femto-lasik surgery |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8346559/ https://www.ncbi.nlm.nih.gov/pubmed/34362982 http://dx.doi.org/10.1038/s41598-021-95730-z |
work_keys_str_mv | AT langongpu customizedeyemodelingforopticalqualityassessmentinmyopicfemtolasiksurgery AT zengjun customizedeyemodelingforopticalqualityassessmentinmyopicfemtolasiksurgery AT liwenjie customizedeyemodelingforopticalqualityassessmentinmyopicfemtolasiksurgery AT maguoqin customizedeyemodelingforopticalqualityassessmentinmyopicfemtolasiksurgery AT shiqun customizedeyemodelingforopticalqualityassessmentinmyopicfemtolasiksurgery AT shiyue customizedeyemodelingforopticalqualityassessmentinmyopicfemtolasiksurgery AT wangyicheng customizedeyemodelingforopticalqualityassessmentinmyopicfemtolasiksurgery AT xujingjiang customizedeyemodelingforopticalqualityassessmentinmyopicfemtolasiksurgery AT huangyanping customizedeyemodelingforopticalqualityassessmentinmyopicfemtolasiksurgery AT qinjia customizedeyemodelingforopticalqualityassessmentinmyopicfemtolasiksurgery AT fengjinping customizedeyemodelingforopticalqualityassessmentinmyopicfemtolasiksurgery AT tanhaishu customizedeyemodelingforopticalqualityassessmentinmyopicfemtolasiksurgery AT anlin customizedeyemodelingforopticalqualityassessmentinmyopicfemtolasiksurgery AT weixunbin customizedeyemodelingforopticalqualityassessmentinmyopicfemtolasiksurgery |