Cargando…
Failure Analysis and Prevention of Extraction Column for Methyl Methacrylate Production: Application of the ‘Safety Design’ Concept
To ensure safety and prevent failure of engineering equipment throughout its lifespan, the concept of ‘Safety Design’ is proposed, which covers all the cradle-to-grave phases of engineering equipment, considers at least ten essential factors of failure causes, and conducts root cause analysis at thr...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8346975/ https://www.ncbi.nlm.nih.gov/pubmed/34361428 http://dx.doi.org/10.3390/ma14154234 |
_version_ | 1783734972146778112 |
---|---|
author | Wang, Sheng-Hui Gong, Yi Tong, Qi Yang, Xiao-Lei Shen, Jia-Hao Yang, Zhen-Guo |
author_facet | Wang, Sheng-Hui Gong, Yi Tong, Qi Yang, Xiao-Lei Shen, Jia-Hao Yang, Zhen-Guo |
author_sort | Wang, Sheng-Hui |
collection | PubMed |
description | To ensure safety and prevent failure of engineering equipment throughout its lifespan, the concept of ‘Safety Design’ is proposed, which covers all the cradle-to-grave phases of engineering equipment, considers at least ten essential factors of failure causes, and conducts root cause analysis at three different scales, in order to proactively control the safety risks before the occurrence of failure rather than passively conduct the remedial measures after failure. Herein, in order to demonstrate how to implement this effective and efficient concept in engineering practice, a case study of failure analysis and prevention is addressed on the extraction column in the production line for methyl methacrylate. Based on the analysis results, the causes were finally determined to be all derived from the stages before operation, including inappropriate design, limited quality inspection of fabrication and installation. Pertinent countermeasures were then proposed from the ‘Safety Design’ point of view, which would not only solve the failure problem for this sole equipment but also contribute to safety risk control of other engineering equipment before operation. |
format | Online Article Text |
id | pubmed-8346975 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-83469752021-08-08 Failure Analysis and Prevention of Extraction Column for Methyl Methacrylate Production: Application of the ‘Safety Design’ Concept Wang, Sheng-Hui Gong, Yi Tong, Qi Yang, Xiao-Lei Shen, Jia-Hao Yang, Zhen-Guo Materials (Basel) Article To ensure safety and prevent failure of engineering equipment throughout its lifespan, the concept of ‘Safety Design’ is proposed, which covers all the cradle-to-grave phases of engineering equipment, considers at least ten essential factors of failure causes, and conducts root cause analysis at three different scales, in order to proactively control the safety risks before the occurrence of failure rather than passively conduct the remedial measures after failure. Herein, in order to demonstrate how to implement this effective and efficient concept in engineering practice, a case study of failure analysis and prevention is addressed on the extraction column in the production line for methyl methacrylate. Based on the analysis results, the causes were finally determined to be all derived from the stages before operation, including inappropriate design, limited quality inspection of fabrication and installation. Pertinent countermeasures were then proposed from the ‘Safety Design’ point of view, which would not only solve the failure problem for this sole equipment but also contribute to safety risk control of other engineering equipment before operation. MDPI 2021-07-29 /pmc/articles/PMC8346975/ /pubmed/34361428 http://dx.doi.org/10.3390/ma14154234 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Wang, Sheng-Hui Gong, Yi Tong, Qi Yang, Xiao-Lei Shen, Jia-Hao Yang, Zhen-Guo Failure Analysis and Prevention of Extraction Column for Methyl Methacrylate Production: Application of the ‘Safety Design’ Concept |
title | Failure Analysis and Prevention of Extraction Column for Methyl Methacrylate Production: Application of the ‘Safety Design’ Concept |
title_full | Failure Analysis and Prevention of Extraction Column for Methyl Methacrylate Production: Application of the ‘Safety Design’ Concept |
title_fullStr | Failure Analysis and Prevention of Extraction Column for Methyl Methacrylate Production: Application of the ‘Safety Design’ Concept |
title_full_unstemmed | Failure Analysis and Prevention of Extraction Column for Methyl Methacrylate Production: Application of the ‘Safety Design’ Concept |
title_short | Failure Analysis and Prevention of Extraction Column for Methyl Methacrylate Production: Application of the ‘Safety Design’ Concept |
title_sort | failure analysis and prevention of extraction column for methyl methacrylate production: application of the ‘safety design’ concept |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8346975/ https://www.ncbi.nlm.nih.gov/pubmed/34361428 http://dx.doi.org/10.3390/ma14154234 |
work_keys_str_mv | AT wangshenghui failureanalysisandpreventionofextractioncolumnformethylmethacrylateproductionapplicationofthesafetydesignconcept AT gongyi failureanalysisandpreventionofextractioncolumnformethylmethacrylateproductionapplicationofthesafetydesignconcept AT tongqi failureanalysisandpreventionofextractioncolumnformethylmethacrylateproductionapplicationofthesafetydesignconcept AT yangxiaolei failureanalysisandpreventionofextractioncolumnformethylmethacrylateproductionapplicationofthesafetydesignconcept AT shenjiahao failureanalysisandpreventionofextractioncolumnformethylmethacrylateproductionapplicationofthesafetydesignconcept AT yangzhenguo failureanalysisandpreventionofextractioncolumnformethylmethacrylateproductionapplicationofthesafetydesignconcept |