Cargando…

Periprosthetic Stress Shielding of the Humerus after Reconstruction with Modular Shoulder Megaprostheses in Patients with Sarcoma

(1) Background: Modular megaprosthetic reconstruction using a proximal humerus replacement has emerged as a commonly chosen approach after bone tumor resection. However, the long-term risk for revision surgery is relatively high. One factor that might be associated with mechanical failures is peripr...

Descripción completa

Detalles Bibliográficos
Autores principales: Klingebiel, Sebastian, Schneider, Kristian Nikolaus, Gosheger, Georg, Ackmann, Thomas, Timme, Maximilian, Rickert, Carolin, Deventer, Niklas, Theil, Christoph
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8347309/
https://www.ncbi.nlm.nih.gov/pubmed/34362209
http://dx.doi.org/10.3390/jcm10153424
Descripción
Sumario:(1) Background: Modular megaprosthetic reconstruction using a proximal humerus replacement has emerged as a commonly chosen approach after bone tumor resection. However, the long-term risk for revision surgery is relatively high. One factor that might be associated with mechanical failures is periprosthetic osteolysis around the stem, also known as stress shielding. The frequency, potential risk factors, and the effect on implant survival are unknown. (2) Methods: A retrospective single-center study of 65 patients with sarcoma who underwent resection of the proximal humerus and subsequent reconstruction with a modular endoprosthesis. Stress shielding was defined as the development of bone resorption around the prosthesis stem beginning at the bone/prosthesis interface. The extent of stress shielding was measured with a new method quantifying bone resorption in relation to the intramedullary stem length. All patients had a minimum follow-up of 12 months with conventional radiographs available and the median follow-up amounted to 36 months. (3) Results: Stress shielding was observed in 92% of patients (60/65). The median longitudinal extent of stress shielding amounted to 14% at last follow-up. Fifteen percent (10/65) showed bone resorption of greater than 50%. The median time to the first radiographic signs of stress shielding was 6 months (IQR 3–9). Patients who underwent chemotherapy (43/65) showed a greater extent of stress shielding compared to those without chemotherapy. Three percent (2/65) of patients were revised for aseptic loosening, and one patient had a periprosthetic fracture (1/65, 1.5%). All these cases had >20% extent of stress shielding (23–57%). (4) Conclusions: Stress shielding of the proximal humerus after shoulder reconstruction with modular megaprosthesis is common. It occurs within the first year of follow-up and might be self-limiting in many patients; however, about one third of patients shows progression beyond the first year. Still, mechanical complications were rare, but stress shielding might be clinically relevant in individual cases. The extent of stress shielding was increased in patients who underwent perioperative chemotherapy. Stress shielding can be quantified with an easy method using the stem length as a reference.