Cargando…

The Solution for the Thermographic Measurement of the Temperature of a Small Object

This article describes the measuring system and the influence of selected factors on the accuracy of thermographic temperature measurement using a macrolens. This method enables thermographic measurement of the temperature of a small object with an area of square millimeters as, e.g., electronic ele...

Descripción completa

Detalles Bibliográficos
Autores principales: Hulewicz, Arkadiusz, Dziarski, Krzysztof, Dombek, Grzegorz
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8347721/
https://www.ncbi.nlm.nih.gov/pubmed/34372237
http://dx.doi.org/10.3390/s21155000
_version_ 1783735161196642304
author Hulewicz, Arkadiusz
Dziarski, Krzysztof
Dombek, Grzegorz
author_facet Hulewicz, Arkadiusz
Dziarski, Krzysztof
Dombek, Grzegorz
author_sort Hulewicz, Arkadiusz
collection PubMed
description This article describes the measuring system and the influence of selected factors on the accuracy of thermographic temperature measurement using a macrolens. This method enables thermographic measurement of the temperature of a small object with an area of square millimeters as, e.g., electronic elements. Damage to electronic components is often preceded by a rise in temperature, and an effective way to diagnose such components is the use of a thermographic camera. The ability to diagnose a device under full load makes thermography a very practical method that allows us to assess the condition of the device during operation. The accuracy of such a measurement depends on the conditions in which it is carried out. The incorrect selection of at least one parameter compensating the influence of the factor occurring during the measurement may cause the indicated value to differ from the correct value. This paper presents the basic issues linked to thermographic measurements and highlights the sources of errors. A measuring stand which enables the assessment of the influence of selected factors on the accuracy of thermographic measurement of electronic elements with the use of a macrolens is presented.
format Online
Article
Text
id pubmed-8347721
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-83477212021-08-08 The Solution for the Thermographic Measurement of the Temperature of a Small Object Hulewicz, Arkadiusz Dziarski, Krzysztof Dombek, Grzegorz Sensors (Basel) Article This article describes the measuring system and the influence of selected factors on the accuracy of thermographic temperature measurement using a macrolens. This method enables thermographic measurement of the temperature of a small object with an area of square millimeters as, e.g., electronic elements. Damage to electronic components is often preceded by a rise in temperature, and an effective way to diagnose such components is the use of a thermographic camera. The ability to diagnose a device under full load makes thermography a very practical method that allows us to assess the condition of the device during operation. The accuracy of such a measurement depends on the conditions in which it is carried out. The incorrect selection of at least one parameter compensating the influence of the factor occurring during the measurement may cause the indicated value to differ from the correct value. This paper presents the basic issues linked to thermographic measurements and highlights the sources of errors. A measuring stand which enables the assessment of the influence of selected factors on the accuracy of thermographic measurement of electronic elements with the use of a macrolens is presented. MDPI 2021-07-23 /pmc/articles/PMC8347721/ /pubmed/34372237 http://dx.doi.org/10.3390/s21155000 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Hulewicz, Arkadiusz
Dziarski, Krzysztof
Dombek, Grzegorz
The Solution for the Thermographic Measurement of the Temperature of a Small Object
title The Solution for the Thermographic Measurement of the Temperature of a Small Object
title_full The Solution for the Thermographic Measurement of the Temperature of a Small Object
title_fullStr The Solution for the Thermographic Measurement of the Temperature of a Small Object
title_full_unstemmed The Solution for the Thermographic Measurement of the Temperature of a Small Object
title_short The Solution for the Thermographic Measurement of the Temperature of a Small Object
title_sort solution for the thermographic measurement of the temperature of a small object
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8347721/
https://www.ncbi.nlm.nih.gov/pubmed/34372237
http://dx.doi.org/10.3390/s21155000
work_keys_str_mv AT hulewiczarkadiusz thesolutionforthethermographicmeasurementofthetemperatureofasmallobject
AT dziarskikrzysztof thesolutionforthethermographicmeasurementofthetemperatureofasmallobject
AT dombekgrzegorz thesolutionforthethermographicmeasurementofthetemperatureofasmallobject
AT hulewiczarkadiusz solutionforthethermographicmeasurementofthetemperatureofasmallobject
AT dziarskikrzysztof solutionforthethermographicmeasurementofthetemperatureofasmallobject
AT dombekgrzegorz solutionforthethermographicmeasurementofthetemperatureofasmallobject