Cargando…

Determination of Lead Employing Simple Flow Injection AAS with Monolithic Alginate-Polyurethane Composite Packed In-Valve Column

A simple flow injection FlameAAS for lead determination with an alginate-polyurethane composite (ALG-PUC) monolithic in-valve column has been developed. The ALG-PUC monolithic rod was prepared by mixing methylene diphenyl diisocyanate with polyol and sodium alginate with the ratio of 2:1:1 by weight...

Descripción completa

Detalles Bibliográficos
Autores principales: Issarangkura Na Ayutthaya, Piyanat, Yeerum, Chonnipa, Kesonkan, Kullapon, Kiwfo, Kanokwan, Grudpan, Kate, Teshima, Norio, Murakami, Hiroya, Vongboot, Monnapat
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8347769/
https://www.ncbi.nlm.nih.gov/pubmed/34361553
http://dx.doi.org/10.3390/molecules26154397
_version_ 1783735173968297984
author Issarangkura Na Ayutthaya, Piyanat
Yeerum, Chonnipa
Kesonkan, Kullapon
Kiwfo, Kanokwan
Grudpan, Kate
Teshima, Norio
Murakami, Hiroya
Vongboot, Monnapat
author_facet Issarangkura Na Ayutthaya, Piyanat
Yeerum, Chonnipa
Kesonkan, Kullapon
Kiwfo, Kanokwan
Grudpan, Kate
Teshima, Norio
Murakami, Hiroya
Vongboot, Monnapat
author_sort Issarangkura Na Ayutthaya, Piyanat
collection PubMed
description A simple flow injection FlameAAS for lead determination with an alginate-polyurethane composite (ALG-PUC) monolithic in-valve column has been developed. The ALG-PUC monolithic rod was prepared by mixing methylene diphenyl diisocyanate with polyol and sodium alginate with the ratio of 2:1:1 by weight for a 5 min polymerization reaction. It was then put into a column (0.8 cm i.d × 11 cm length) situated in a switching valve for the FI set up. A single standard calibration could be obtained by plotting the loaded µg Pb(2+) vs. FI response (absorbances). The loaded µg Pb(2+) is calculated: μg Pb(2+) = FR(load) × LT × C(Pb)(2+), where the FR load is the flow rate of the loading analyte solution (mL min(−1)), LT is the loading time (min), and C(Pb)(2+) is the Pb(2+) concentration (µg mL(−1)). A linear calibration equation was obtained: FI response (absorbances) = 0.0018 [µg Pb(2+)] + 0.0032, R(2) = 0.9927 for 1–150 µg Pb(2+), and RSD of less than 20% was also obtained. Application of the developed procedure has been demonstrated in real samples.
format Online
Article
Text
id pubmed-8347769
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-83477692021-08-08 Determination of Lead Employing Simple Flow Injection AAS with Monolithic Alginate-Polyurethane Composite Packed In-Valve Column Issarangkura Na Ayutthaya, Piyanat Yeerum, Chonnipa Kesonkan, Kullapon Kiwfo, Kanokwan Grudpan, Kate Teshima, Norio Murakami, Hiroya Vongboot, Monnapat Molecules Article A simple flow injection FlameAAS for lead determination with an alginate-polyurethane composite (ALG-PUC) monolithic in-valve column has been developed. The ALG-PUC monolithic rod was prepared by mixing methylene diphenyl diisocyanate with polyol and sodium alginate with the ratio of 2:1:1 by weight for a 5 min polymerization reaction. It was then put into a column (0.8 cm i.d × 11 cm length) situated in a switching valve for the FI set up. A single standard calibration could be obtained by plotting the loaded µg Pb(2+) vs. FI response (absorbances). The loaded µg Pb(2+) is calculated: μg Pb(2+) = FR(load) × LT × C(Pb)(2+), where the FR load is the flow rate of the loading analyte solution (mL min(−1)), LT is the loading time (min), and C(Pb)(2+) is the Pb(2+) concentration (µg mL(−1)). A linear calibration equation was obtained: FI response (absorbances) = 0.0018 [µg Pb(2+)] + 0.0032, R(2) = 0.9927 for 1–150 µg Pb(2+), and RSD of less than 20% was also obtained. Application of the developed procedure has been demonstrated in real samples. MDPI 2021-07-21 /pmc/articles/PMC8347769/ /pubmed/34361553 http://dx.doi.org/10.3390/molecules26154397 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Issarangkura Na Ayutthaya, Piyanat
Yeerum, Chonnipa
Kesonkan, Kullapon
Kiwfo, Kanokwan
Grudpan, Kate
Teshima, Norio
Murakami, Hiroya
Vongboot, Monnapat
Determination of Lead Employing Simple Flow Injection AAS with Monolithic Alginate-Polyurethane Composite Packed In-Valve Column
title Determination of Lead Employing Simple Flow Injection AAS with Monolithic Alginate-Polyurethane Composite Packed In-Valve Column
title_full Determination of Lead Employing Simple Flow Injection AAS with Monolithic Alginate-Polyurethane Composite Packed In-Valve Column
title_fullStr Determination of Lead Employing Simple Flow Injection AAS with Monolithic Alginate-Polyurethane Composite Packed In-Valve Column
title_full_unstemmed Determination of Lead Employing Simple Flow Injection AAS with Monolithic Alginate-Polyurethane Composite Packed In-Valve Column
title_short Determination of Lead Employing Simple Flow Injection AAS with Monolithic Alginate-Polyurethane Composite Packed In-Valve Column
title_sort determination of lead employing simple flow injection aas with monolithic alginate-polyurethane composite packed in-valve column
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8347769/
https://www.ncbi.nlm.nih.gov/pubmed/34361553
http://dx.doi.org/10.3390/molecules26154397
work_keys_str_mv AT issarangkuranaayutthayapiyanat determinationofleademployingsimpleflowinjectionaaswithmonolithicalginatepolyurethanecompositepackedinvalvecolumn
AT yeerumchonnipa determinationofleademployingsimpleflowinjectionaaswithmonolithicalginatepolyurethanecompositepackedinvalvecolumn
AT kesonkankullapon determinationofleademployingsimpleflowinjectionaaswithmonolithicalginatepolyurethanecompositepackedinvalvecolumn
AT kiwfokanokwan determinationofleademployingsimpleflowinjectionaaswithmonolithicalginatepolyurethanecompositepackedinvalvecolumn
AT grudpankate determinationofleademployingsimpleflowinjectionaaswithmonolithicalginatepolyurethanecompositepackedinvalvecolumn
AT teshimanorio determinationofleademployingsimpleflowinjectionaaswithmonolithicalginatepolyurethanecompositepackedinvalvecolumn
AT murakamihiroya determinationofleademployingsimpleflowinjectionaaswithmonolithicalginatepolyurethanecompositepackedinvalvecolumn
AT vongbootmonnapat determinationofleademployingsimpleflowinjectionaaswithmonolithicalginatepolyurethanecompositepackedinvalvecolumn