Cargando…

Influence of an Implant Fixture including a Freely Removable Micro-Locking Implant Prosthesis on Peri-Implant Tissues and Implant Prostheses: A Prospective Clinical Study

This prospective study was undertaken to evaluate the clinical usefulness of a newly developed one-piece, screw-free, and micro-locking implant system, which was designed to overcome the shortcomings of the existing implant systems. Thirty-eight patients were recruited and randomly and equally assig...

Descripción completa

Detalles Bibliográficos
Autores principales: Shin, Young-Gun, Cho, Won-Tak, Lim, Ho-Kyung, Hwang, Su-Hyun, Bae, Ji-Hyeon, Bae, Gang-Ho, Lee, Jeong-Yol, Huh, Jung-Bo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8348657/
https://www.ncbi.nlm.nih.gov/pubmed/34362106
http://dx.doi.org/10.3390/jcm10153321
_version_ 1783735393377583104
author Shin, Young-Gun
Cho, Won-Tak
Lim, Ho-Kyung
Hwang, Su-Hyun
Bae, Ji-Hyeon
Bae, Gang-Ho
Lee, Jeong-Yol
Huh, Jung-Bo
author_facet Shin, Young-Gun
Cho, Won-Tak
Lim, Ho-Kyung
Hwang, Su-Hyun
Bae, Ji-Hyeon
Bae, Gang-Ho
Lee, Jeong-Yol
Huh, Jung-Bo
author_sort Shin, Young-Gun
collection PubMed
description This prospective study was undertaken to evaluate the clinical usefulness of a newly developed one-piece, screw-free, and micro-locking implant system, which was designed to overcome the shortcomings of the existing implant systems. Thirty-eight patients were recruited and randomly and equally assigned to an experimental group (micro-locking one-piece fixture, MLF; n = 19) or a control group (micro-locking abutment, MLA). Cumulative implant survival rates, marginal bone resorptions, probing depths, plaque indices, bleeding indices, and complications were obtained by using clinical and radiographic findings at 6 months and 12 months after prosthesis placement. Complications that occurred multiple times for single implants were counted. During the 12 month observation period, survival rates were 100% in both groups. No significant intergroup differences were observed for marginal bone resorption, probe depth, or bleeding index. However, mean plaque index was significantly lower in the MLF group at 12 months (p < 0.05). During the 12-month observation period, food impaction (26.3%) was the main complication in the MLF group and screw loosening (5.3%), prosthesis detachment (5.3%), and food impaction (5.3%) were observed in the MLA group. The results of this study suggest that the one-piece micro-locking implant system offers a predictable treatment method.
format Online
Article
Text
id pubmed-8348657
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-83486572021-08-08 Influence of an Implant Fixture including a Freely Removable Micro-Locking Implant Prosthesis on Peri-Implant Tissues and Implant Prostheses: A Prospective Clinical Study Shin, Young-Gun Cho, Won-Tak Lim, Ho-Kyung Hwang, Su-Hyun Bae, Ji-Hyeon Bae, Gang-Ho Lee, Jeong-Yol Huh, Jung-Bo J Clin Med Article This prospective study was undertaken to evaluate the clinical usefulness of a newly developed one-piece, screw-free, and micro-locking implant system, which was designed to overcome the shortcomings of the existing implant systems. Thirty-eight patients were recruited and randomly and equally assigned to an experimental group (micro-locking one-piece fixture, MLF; n = 19) or a control group (micro-locking abutment, MLA). Cumulative implant survival rates, marginal bone resorptions, probing depths, plaque indices, bleeding indices, and complications were obtained by using clinical and radiographic findings at 6 months and 12 months after prosthesis placement. Complications that occurred multiple times for single implants were counted. During the 12 month observation period, survival rates were 100% in both groups. No significant intergroup differences were observed for marginal bone resorption, probe depth, or bleeding index. However, mean plaque index was significantly lower in the MLF group at 12 months (p < 0.05). During the 12-month observation period, food impaction (26.3%) was the main complication in the MLF group and screw loosening (5.3%), prosthesis detachment (5.3%), and food impaction (5.3%) were observed in the MLA group. The results of this study suggest that the one-piece micro-locking implant system offers a predictable treatment method. MDPI 2021-07-28 /pmc/articles/PMC8348657/ /pubmed/34362106 http://dx.doi.org/10.3390/jcm10153321 Text en © 2021 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Shin, Young-Gun
Cho, Won-Tak
Lim, Ho-Kyung
Hwang, Su-Hyun
Bae, Ji-Hyeon
Bae, Gang-Ho
Lee, Jeong-Yol
Huh, Jung-Bo
Influence of an Implant Fixture including a Freely Removable Micro-Locking Implant Prosthesis on Peri-Implant Tissues and Implant Prostheses: A Prospective Clinical Study
title Influence of an Implant Fixture including a Freely Removable Micro-Locking Implant Prosthesis on Peri-Implant Tissues and Implant Prostheses: A Prospective Clinical Study
title_full Influence of an Implant Fixture including a Freely Removable Micro-Locking Implant Prosthesis on Peri-Implant Tissues and Implant Prostheses: A Prospective Clinical Study
title_fullStr Influence of an Implant Fixture including a Freely Removable Micro-Locking Implant Prosthesis on Peri-Implant Tissues and Implant Prostheses: A Prospective Clinical Study
title_full_unstemmed Influence of an Implant Fixture including a Freely Removable Micro-Locking Implant Prosthesis on Peri-Implant Tissues and Implant Prostheses: A Prospective Clinical Study
title_short Influence of an Implant Fixture including a Freely Removable Micro-Locking Implant Prosthesis on Peri-Implant Tissues and Implant Prostheses: A Prospective Clinical Study
title_sort influence of an implant fixture including a freely removable micro-locking implant prosthesis on peri-implant tissues and implant prostheses: a prospective clinical study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8348657/
https://www.ncbi.nlm.nih.gov/pubmed/34362106
http://dx.doi.org/10.3390/jcm10153321
work_keys_str_mv AT shinyounggun influenceofanimplantfixtureincludingafreelyremovablemicrolockingimplantprosthesisonperiimplanttissuesandimplantprosthesesaprospectiveclinicalstudy
AT chowontak influenceofanimplantfixtureincludingafreelyremovablemicrolockingimplantprosthesisonperiimplanttissuesandimplantprosthesesaprospectiveclinicalstudy
AT limhokyung influenceofanimplantfixtureincludingafreelyremovablemicrolockingimplantprosthesisonperiimplanttissuesandimplantprosthesesaprospectiveclinicalstudy
AT hwangsuhyun influenceofanimplantfixtureincludingafreelyremovablemicrolockingimplantprosthesisonperiimplanttissuesandimplantprosthesesaprospectiveclinicalstudy
AT baejihyeon influenceofanimplantfixtureincludingafreelyremovablemicrolockingimplantprosthesisonperiimplanttissuesandimplantprosthesesaprospectiveclinicalstudy
AT baegangho influenceofanimplantfixtureincludingafreelyremovablemicrolockingimplantprosthesisonperiimplanttissuesandimplantprosthesesaprospectiveclinicalstudy
AT leejeongyol influenceofanimplantfixtureincludingafreelyremovablemicrolockingimplantprosthesisonperiimplanttissuesandimplantprosthesesaprospectiveclinicalstudy
AT huhjungbo influenceofanimplantfixtureincludingafreelyremovablemicrolockingimplantprosthesisonperiimplanttissuesandimplantprosthesesaprospectiveclinicalstudy