Cargando…

Integrity of dural closure after autologous platelet rich fibrin augmentation: an in vitro study

BACKGROUND: Watertight closure of the dura mater is fundamental in neurosurgery. Besides the classical suturing techniques, a variety of biomaterials have been proposed as sealants. Platelet rich fibrin (PRF) is an autologous biomaterial which can readily be obtained through low-speed centrifugation...

Descripción completa

Detalles Bibliográficos
Autores principales: Vasilikos, I., Beck, J., Ghanaati, S., Grauvogel, J., Nisyrios, T., Grapatsas, K., Hubbe, U.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Vienna 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8349340/
https://www.ncbi.nlm.nih.gov/pubmed/32034495
http://dx.doi.org/10.1007/s00701-020-04254-4
Descripción
Sumario:BACKGROUND: Watertight closure of the dura mater is fundamental in neurosurgery. Besides the classical suturing techniques, a variety of biomaterials have been proposed as sealants. Platelet rich fibrin (PRF) is an autologous biomaterial which can readily be obtained through low-speed centrifugation of patient’s own blood. It is rich in fibrin, growth factors, leucocytes and cytokines and has shown adhesive properties while promoting the physiological wound healing process. In this study, we investigated the effect of applying PRF in reinforcing the watertight dura mater closure. METHODS: We created an in vitro testing device, where the watertight dura mater closure could be hydrostatically assessed. On 26 fresh harvested bovine dura maters, a standardised 20-mm incision was closed with a running suture, and the leak pressure was measured first without (primary leak pressure) and then with PRF augmentation (secondary leak pressure). The two groups of measurements have been statistically analysed with the Student’s paired t test. RESULTS: The “running suture only group” had a leak pressure of 10.5 ± 1.2 cmH2O (mean ± SD) while the “PRF-augmented group” had a leak pressure of 47.2 ± 2.6 cm H2O. This difference was statistically significant (p < 0.001; paired t test). CONCLUSIONS: Autologous platelet rich fibrin augmentation reliably reinforced watertight closure of the dura mater to a > 4-fold increased leak pressure after failure of the initial standard running suture technique. ELECTRONIC SUPPLEMENTARY MATERIAL: The online version of this article (10.1007/s00701-020-04254-4) contains supplementary material, which is available to authorized users.