Cargando…

Mobile 3-dimensional (3D) C-arm system-assisted transbronchial biopsy and ablation for ground-glass opacity pulmonary nodules: a case report

Identification of pulmonary ground-glass opacity (GGO) lesions during bronchoscopic procedures remains challenging, as GGOs cannot be directly visualized under 2-dimensional (2D) fluoroscopy and are often difficult to detect by radial endobronchial ultrasound. Recently, a mobile 2D/3D C-arm fluorosc...

Descripción completa

Detalles Bibliográficos
Autores principales: Chen, Junxiang, Xie, Fangfang, Zheng, Xiaoxuan, Li, Ying, Liu, Shuaiyang, Ma, Kevin C., Goto, Taichiro, Müller, Tobias, Chan, Edward D., Sun, Jiayuan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: AME Publishing Company 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8350092/
https://www.ncbi.nlm.nih.gov/pubmed/34430367
http://dx.doi.org/10.21037/tlcr-21-561
_version_ 1783735678899585024
author Chen, Junxiang
Xie, Fangfang
Zheng, Xiaoxuan
Li, Ying
Liu, Shuaiyang
Ma, Kevin C.
Goto, Taichiro
Müller, Tobias
Chan, Edward D.
Sun, Jiayuan
author_facet Chen, Junxiang
Xie, Fangfang
Zheng, Xiaoxuan
Li, Ying
Liu, Shuaiyang
Ma, Kevin C.
Goto, Taichiro
Müller, Tobias
Chan, Edward D.
Sun, Jiayuan
author_sort Chen, Junxiang
collection PubMed
description Identification of pulmonary ground-glass opacity (GGO) lesions during bronchoscopic procedures remains challenging, as GGOs cannot be directly visualized under 2-dimensional (2D) fluoroscopy and are often difficult to detect by radial endobronchial ultrasound. Recently, a mobile 2D/3D C-arm fluoroscopy system was developed that provides both 2D fluoroscopy and mobile 3D imaging to assess and confirm the location of the lesions and ancillary bronchoscopic tools. However, previous studies focused mainly on experience of utilizing mobile 3D C-arm system for transbronchial biopsy of solid pulmonary nodules. Here, we evaluated the feasibility of mobile 3D imaging assisted transbronchial biopsy with and without ablation of two patients with GGO nodules. The first patient underwent biopsy only, and the second patient underwent biopsy in the right upper lobe lung nodule and ablation of a left upper lobe lung nodule in one session. Procedures in both patients were successfully performed, and no significant complications have been observed intra- or post-procedurally. Our case study highlights the potential value of the mobile 3D imaging system in accurate identification of the target lung lesion, confirmation of bronchoscopic tools within the lesion, and assessment of the target lesion and surrounding tissue following bronchoscopic ablation procedure. Furthermore, a “one-stop shop” bronchoscopy workflow combining both biopsy and ablation for one or more lung lesions in one session could be made possible by utilizing a hybrid mobile 2D/3D C-arm system in the bronchoscopy suite.
format Online
Article
Text
id pubmed-8350092
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher AME Publishing Company
record_format MEDLINE/PubMed
spelling pubmed-83500922021-08-23 Mobile 3-dimensional (3D) C-arm system-assisted transbronchial biopsy and ablation for ground-glass opacity pulmonary nodules: a case report Chen, Junxiang Xie, Fangfang Zheng, Xiaoxuan Li, Ying Liu, Shuaiyang Ma, Kevin C. Goto, Taichiro Müller, Tobias Chan, Edward D. Sun, Jiayuan Transl Lung Cancer Res Case Report Identification of pulmonary ground-glass opacity (GGO) lesions during bronchoscopic procedures remains challenging, as GGOs cannot be directly visualized under 2-dimensional (2D) fluoroscopy and are often difficult to detect by radial endobronchial ultrasound. Recently, a mobile 2D/3D C-arm fluoroscopy system was developed that provides both 2D fluoroscopy and mobile 3D imaging to assess and confirm the location of the lesions and ancillary bronchoscopic tools. However, previous studies focused mainly on experience of utilizing mobile 3D C-arm system for transbronchial biopsy of solid pulmonary nodules. Here, we evaluated the feasibility of mobile 3D imaging assisted transbronchial biopsy with and without ablation of two patients with GGO nodules. The first patient underwent biopsy only, and the second patient underwent biopsy in the right upper lobe lung nodule and ablation of a left upper lobe lung nodule in one session. Procedures in both patients were successfully performed, and no significant complications have been observed intra- or post-procedurally. Our case study highlights the potential value of the mobile 3D imaging system in accurate identification of the target lung lesion, confirmation of bronchoscopic tools within the lesion, and assessment of the target lesion and surrounding tissue following bronchoscopic ablation procedure. Furthermore, a “one-stop shop” bronchoscopy workflow combining both biopsy and ablation for one or more lung lesions in one session could be made possible by utilizing a hybrid mobile 2D/3D C-arm system in the bronchoscopy suite. AME Publishing Company 2021-07 /pmc/articles/PMC8350092/ /pubmed/34430367 http://dx.doi.org/10.21037/tlcr-21-561 Text en 2021 Translational Lung Cancer Research. All rights reserved. https://creativecommons.org/licenses/by-nc-nd/4.0/Open Access Statement: This is an Open Access article distributed in accordance with the Creative Commons Attribution-NonCommercial-NoDerivs 4.0 International License (CC BY-NC-ND 4.0), which permits the non-commercial replication and distribution of the article with the strict proviso that no changes or edits are made and the original work is properly cited (including links to both the formal publication through the relevant DOI and the license). See: https://creativecommons.org/licenses/by-nc-nd/4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) .
spellingShingle Case Report
Chen, Junxiang
Xie, Fangfang
Zheng, Xiaoxuan
Li, Ying
Liu, Shuaiyang
Ma, Kevin C.
Goto, Taichiro
Müller, Tobias
Chan, Edward D.
Sun, Jiayuan
Mobile 3-dimensional (3D) C-arm system-assisted transbronchial biopsy and ablation for ground-glass opacity pulmonary nodules: a case report
title Mobile 3-dimensional (3D) C-arm system-assisted transbronchial biopsy and ablation for ground-glass opacity pulmonary nodules: a case report
title_full Mobile 3-dimensional (3D) C-arm system-assisted transbronchial biopsy and ablation for ground-glass opacity pulmonary nodules: a case report
title_fullStr Mobile 3-dimensional (3D) C-arm system-assisted transbronchial biopsy and ablation for ground-glass opacity pulmonary nodules: a case report
title_full_unstemmed Mobile 3-dimensional (3D) C-arm system-assisted transbronchial biopsy and ablation for ground-glass opacity pulmonary nodules: a case report
title_short Mobile 3-dimensional (3D) C-arm system-assisted transbronchial biopsy and ablation for ground-glass opacity pulmonary nodules: a case report
title_sort mobile 3-dimensional (3d) c-arm system-assisted transbronchial biopsy and ablation for ground-glass opacity pulmonary nodules: a case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8350092/
https://www.ncbi.nlm.nih.gov/pubmed/34430367
http://dx.doi.org/10.21037/tlcr-21-561
work_keys_str_mv AT chenjunxiang mobile3dimensional3dcarmsystemassistedtransbronchialbiopsyandablationforgroundglassopacitypulmonarynodulesacasereport
AT xiefangfang mobile3dimensional3dcarmsystemassistedtransbronchialbiopsyandablationforgroundglassopacitypulmonarynodulesacasereport
AT zhengxiaoxuan mobile3dimensional3dcarmsystemassistedtransbronchialbiopsyandablationforgroundglassopacitypulmonarynodulesacasereport
AT liying mobile3dimensional3dcarmsystemassistedtransbronchialbiopsyandablationforgroundglassopacitypulmonarynodulesacasereport
AT liushuaiyang mobile3dimensional3dcarmsystemassistedtransbronchialbiopsyandablationforgroundglassopacitypulmonarynodulesacasereport
AT makevinc mobile3dimensional3dcarmsystemassistedtransbronchialbiopsyandablationforgroundglassopacitypulmonarynodulesacasereport
AT gototaichiro mobile3dimensional3dcarmsystemassistedtransbronchialbiopsyandablationforgroundglassopacitypulmonarynodulesacasereport
AT mullertobias mobile3dimensional3dcarmsystemassistedtransbronchialbiopsyandablationforgroundglassopacitypulmonarynodulesacasereport
AT chanedwardd mobile3dimensional3dcarmsystemassistedtransbronchialbiopsyandablationforgroundglassopacitypulmonarynodulesacasereport
AT sunjiayuan mobile3dimensional3dcarmsystemassistedtransbronchialbiopsyandablationforgroundglassopacitypulmonarynodulesacasereport