Cargando…

Intrastent haematoma after treatment with a drug-eluting balloon for in-stent restenosis: a case report

BACKGROUND: Intrastent haematoma after dilatation of in-stent restenosis (ISR) is rarely reported and the optimal treatment for this condition remains unclear. CASE SUMMARY: We present the case of an 87-year-old man with in-stent subtotal occlusion of left circumflex. He experienced chest pain after...

Descripción completa

Detalles Bibliográficos
Autores principales: Hong, Xu-Lin, Fu, Guo-Sheng, Li, Zhan-Lu, Zhang, Wen-Bin
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Oxford University Press 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8350352/
https://www.ncbi.nlm.nih.gov/pubmed/34377925
http://dx.doi.org/10.1093/ehjcr/ytab295
_version_ 1783735742371987456
author Hong, Xu-Lin
Fu, Guo-Sheng
Li, Zhan-Lu
Zhang, Wen-Bin
author_facet Hong, Xu-Lin
Fu, Guo-Sheng
Li, Zhan-Lu
Zhang, Wen-Bin
author_sort Hong, Xu-Lin
collection PubMed
description BACKGROUND: Intrastent haematoma after dilatation of in-stent restenosis (ISR) is rarely reported and the optimal treatment for this condition remains unclear. CASE SUMMARY: We present the case of an 87-year-old man with in-stent subtotal occlusion of left circumflex. He experienced chest pain after drug-eluting balloon was released in the stent. Intravascular ultrasound revealed intrastent haematoma, which was not relieved with a cutting balloon but completely sealed by an Endeavor Resolute stent. DISCUSSION: Intrastent haematoma after dilatation of ISR is rare. Reimplantation of stent seems the best method to solve this problem. Intravascular ultrasound imaging may provide insight into the cause of ISR and guide the treatment.
format Online
Article
Text
id pubmed-8350352
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Oxford University Press
record_format MEDLINE/PubMed
spelling pubmed-83503522021-08-09 Intrastent haematoma after treatment with a drug-eluting balloon for in-stent restenosis: a case report Hong, Xu-Lin Fu, Guo-Sheng Li, Zhan-Lu Zhang, Wen-Bin Eur Heart J Case Rep Case Report BACKGROUND: Intrastent haematoma after dilatation of in-stent restenosis (ISR) is rarely reported and the optimal treatment for this condition remains unclear. CASE SUMMARY: We present the case of an 87-year-old man with in-stent subtotal occlusion of left circumflex. He experienced chest pain after drug-eluting balloon was released in the stent. Intravascular ultrasound revealed intrastent haematoma, which was not relieved with a cutting balloon but completely sealed by an Endeavor Resolute stent. DISCUSSION: Intrastent haematoma after dilatation of ISR is rare. Reimplantation of stent seems the best method to solve this problem. Intravascular ultrasound imaging may provide insight into the cause of ISR and guide the treatment. Oxford University Press 2021-08-09 /pmc/articles/PMC8350352/ /pubmed/34377925 http://dx.doi.org/10.1093/ehjcr/ytab295 Text en © The Author(s) 2021. Published by Oxford University Press on behalf of the European Society of Cardiology. https://creativecommons.org/licenses/by-nc/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) ), which permits non-commercial re-use, distribution, and reproduction in any medium, provided the original work is properly cited. For commercial re-use, please contact journals.permissions@oup.com
spellingShingle Case Report
Hong, Xu-Lin
Fu, Guo-Sheng
Li, Zhan-Lu
Zhang, Wen-Bin
Intrastent haematoma after treatment with a drug-eluting balloon for in-stent restenosis: a case report
title Intrastent haematoma after treatment with a drug-eluting balloon for in-stent restenosis: a case report
title_full Intrastent haematoma after treatment with a drug-eluting balloon for in-stent restenosis: a case report
title_fullStr Intrastent haematoma after treatment with a drug-eluting balloon for in-stent restenosis: a case report
title_full_unstemmed Intrastent haematoma after treatment with a drug-eluting balloon for in-stent restenosis: a case report
title_short Intrastent haematoma after treatment with a drug-eluting balloon for in-stent restenosis: a case report
title_sort intrastent haematoma after treatment with a drug-eluting balloon for in-stent restenosis: a case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8350352/
https://www.ncbi.nlm.nih.gov/pubmed/34377925
http://dx.doi.org/10.1093/ehjcr/ytab295
work_keys_str_mv AT hongxulin intrastenthaematomaaftertreatmentwithadrugelutingballoonforinstentrestenosisacasereport
AT fuguosheng intrastenthaematomaaftertreatmentwithadrugelutingballoonforinstentrestenosisacasereport
AT lizhanlu intrastenthaematomaaftertreatmentwithadrugelutingballoonforinstentrestenosisacasereport
AT zhangwenbin intrastenthaematomaaftertreatmentwithadrugelutingballoonforinstentrestenosisacasereport