Multiple Myeloma, Hyperviscosity, Hemodialysis Filter Clogging, and Antigen Excess Artifact: A Case Report
Kidney involvement in multiple myeloma can result in kidney failure. Unlike Waldenström macroglobulinemia, hyperviscosity syndrome is a rare occurrence in multiple myeloma. Timely detection of hyperviscosity syndrome and initiation of plasma exchange to remove paraproteins can significantly alter th...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8350819/ https://www.ncbi.nlm.nih.gov/pubmed/34401731 http://dx.doi.org/10.1016/j.xkme.2021.02.011 |
_version_ | 1783735852317278208 |
---|---|
author | Kanduri, Swetha Rani LeDoux, Jason R. Kovvuru, Karthik Wu, Qingli Velez, Juan Carlos |
author_facet | Kanduri, Swetha Rani LeDoux, Jason R. Kovvuru, Karthik Wu, Qingli Velez, Juan Carlos |
author_sort | Kanduri, Swetha Rani |
collection | PubMed |
description | Kidney involvement in multiple myeloma can result in kidney failure. Unlike Waldenström macroglobulinemia, hyperviscosity syndrome is a rare occurrence in multiple myeloma. Timely detection of hyperviscosity syndrome and initiation of plasma exchange to remove paraproteins can significantly alter the clinical course and be potentially lifesaving. We report a case of hospitalized patient with kidney failure due to multiple myeloma not in remission who experienced shortened hemodialysis sessions due to early dialysis filter failure due to hyperviscosity, which was later corrected with plasmapheresis. When confirmation of high levels of serum free light chains (sFLCs) was attempted, sFLC was initially reported as “not detectable.” This false-negative result reflected a laboratory artifact caused by a high abundance of sFLCs, known as antigen excess or hook phenomenon. Manual serial dilutions led to unmasking of markedly elevated κ light chain levels. This case exemplifies that patients with multiple myeloma can exhibit clinically challenging kidney manifestations even after becoming dialysis dependent. |
format | Online Article Text |
id | pubmed-8350819 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-83508192021-08-15 Multiple Myeloma, Hyperviscosity, Hemodialysis Filter Clogging, and Antigen Excess Artifact: A Case Report Kanduri, Swetha Rani LeDoux, Jason R. Kovvuru, Karthik Wu, Qingli Velez, Juan Carlos Kidney Med Case Report Kidney involvement in multiple myeloma can result in kidney failure. Unlike Waldenström macroglobulinemia, hyperviscosity syndrome is a rare occurrence in multiple myeloma. Timely detection of hyperviscosity syndrome and initiation of plasma exchange to remove paraproteins can significantly alter the clinical course and be potentially lifesaving. We report a case of hospitalized patient with kidney failure due to multiple myeloma not in remission who experienced shortened hemodialysis sessions due to early dialysis filter failure due to hyperviscosity, which was later corrected with plasmapheresis. When confirmation of high levels of serum free light chains (sFLCs) was attempted, sFLC was initially reported as “not detectable.” This false-negative result reflected a laboratory artifact caused by a high abundance of sFLCs, known as antigen excess or hook phenomenon. Manual serial dilutions led to unmasking of markedly elevated κ light chain levels. This case exemplifies that patients with multiple myeloma can exhibit clinically challenging kidney manifestations even after becoming dialysis dependent. Elsevier 2021-04-21 /pmc/articles/PMC8350819/ /pubmed/34401731 http://dx.doi.org/10.1016/j.xkme.2021.02.011 Text en © 2021 The Authors https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Case Report Kanduri, Swetha Rani LeDoux, Jason R. Kovvuru, Karthik Wu, Qingli Velez, Juan Carlos Multiple Myeloma, Hyperviscosity, Hemodialysis Filter Clogging, and Antigen Excess Artifact: A Case Report |
title | Multiple Myeloma, Hyperviscosity, Hemodialysis Filter Clogging, and Antigen Excess Artifact: A Case Report |
title_full | Multiple Myeloma, Hyperviscosity, Hemodialysis Filter Clogging, and Antigen Excess Artifact: A Case Report |
title_fullStr | Multiple Myeloma, Hyperviscosity, Hemodialysis Filter Clogging, and Antigen Excess Artifact: A Case Report |
title_full_unstemmed | Multiple Myeloma, Hyperviscosity, Hemodialysis Filter Clogging, and Antigen Excess Artifact: A Case Report |
title_short | Multiple Myeloma, Hyperviscosity, Hemodialysis Filter Clogging, and Antigen Excess Artifact: A Case Report |
title_sort | multiple myeloma, hyperviscosity, hemodialysis filter clogging, and antigen excess artifact: a case report |
topic | Case Report |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8350819/ https://www.ncbi.nlm.nih.gov/pubmed/34401731 http://dx.doi.org/10.1016/j.xkme.2021.02.011 |
work_keys_str_mv | AT kanduriswetharani multiplemyelomahyperviscosityhemodialysisfiltercloggingandantigenexcessartifactacasereport AT ledouxjasonr multiplemyelomahyperviscosityhemodialysisfiltercloggingandantigenexcessartifactacasereport AT kovvurukarthik multiplemyelomahyperviscosityhemodialysisfiltercloggingandantigenexcessartifactacasereport AT wuqingli multiplemyelomahyperviscosityhemodialysisfiltercloggingandantigenexcessartifactacasereport AT velezjuancarlos multiplemyelomahyperviscosityhemodialysisfiltercloggingandantigenexcessartifactacasereport |