Cargando…
Lag-Screw Osteosynthesis in Thoracolumbar Pincer Fractures
STUDY DESIGN: Biomechanical. OBJECTIVE: This study evaluates the biomechanical properties of lag-screws used in vertebral pincer fractures at the thoracolumbar junction. METHODS: Pincer fractures were created in 18 bisegmental human specimens. The specimens were assigned to three groups depending on...
Autores principales: | Auerswald, Marc, Messer-Hannemann, Philipp, Sellenschloh, Kay, Wahlefeld, Jan, Püschel, Klaus, Araujo, Sven Hirschfeld, Morlock, Michael M., Schulz, Arndt P., Huber, Gerd |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2020
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8351070/ https://www.ncbi.nlm.nih.gov/pubmed/32744071 http://dx.doi.org/10.1177/2192568220941443 |