Cargando…

ICA-based denoising strategies in breath-hold induced cerebrovascular reactivity mapping with multi echo BOLD fMRI

Performing a BOLD functional MRI (fMRI) acquisition during breath-hold (BH) tasks is a non-invasive, robust method to estimate cerebrovascular reactivity (CVR). However, movement and breathing-related artefacts caused by the BH can substantially hinder CVR estimates due to their high temporal collin...

Descripción completa

Detalles Bibliográficos
Autores principales: Moia, Stefano, Termenon, Maite, Uruñuela, Eneko, Chen, Gang, Stickland, Rachael C., Bright, Molly G., Caballero-Gaudes, César
Formato: Online Artículo Texto
Lenguaje:English
Publicado: 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8351526/
https://www.ncbi.nlm.nih.gov/pubmed/33684602
http://dx.doi.org/10.1016/j.neuroimage.2021.117914
_version_ 1783735991251501056
author Moia, Stefano
Termenon, Maite
Uruñuela, Eneko
Chen, Gang
Stickland, Rachael C.
Bright, Molly G.
Caballero-Gaudes, César
author_facet Moia, Stefano
Termenon, Maite
Uruñuela, Eneko
Chen, Gang
Stickland, Rachael C.
Bright, Molly G.
Caballero-Gaudes, César
author_sort Moia, Stefano
collection PubMed
description Performing a BOLD functional MRI (fMRI) acquisition during breath-hold (BH) tasks is a non-invasive, robust method to estimate cerebrovascular reactivity (CVR). However, movement and breathing-related artefacts caused by the BH can substantially hinder CVR estimates due to their high temporal collinearity with the effect of interest, and attention has to be paid when choosing which analysis model should be applied to the data. In this study, we evaluate the performance of multiple analysis strategies based on lagged general linear models applied on multi-echo BOLD fMRI data, acquired in ten subjects performing a BH task during ten sessions, to obtain subject-specific CVR and haemodynamic lag estimates. The evaluated approaches range from conventional regression models, i.e. including drifts and motion timecourses as nuisance regressors, applied on single-echo or optimally-combined data, to more complex models including regressors obtained from multi-echo independent component analysis with different grades of orthogonalization in order to preserve the effect of interest, i.e. the CVR. We compare these models in terms of their ability to make signal intensity changes independent from motion, as well as the reliability as measured by voxelwise intraclass correlation coefficients of both CVR and lag maps over time. Our results reveal that a conservative independent component analysis model applied on the optimally-combined multi-echo fMRI signal offers the largest reduction of motion-related effects in the signal, while yielding reliable CVR amplitude and lag estimates, although a conventional regression model applied on the optimally-combined data results in similar estimates. This work demonstrates the usefulness of multi-echo based fMRI acquisitions and independent component analysis denoising for precision mapping of CVR in single subjects based on BH paradigms, fostering its potential as a clinically-viable neuroimaging tool for individual patients. It also proves that the way in which data-driven regressors should be incorporated in the analysis model is not straight-forward due to their complex interaction with the BH-induced BOLD response.
format Online
Article
Text
id pubmed-8351526
institution National Center for Biotechnology Information
language English
publishDate 2021
record_format MEDLINE/PubMed
spelling pubmed-83515262021-08-09 ICA-based denoising strategies in breath-hold induced cerebrovascular reactivity mapping with multi echo BOLD fMRI Moia, Stefano Termenon, Maite Uruñuela, Eneko Chen, Gang Stickland, Rachael C. Bright, Molly G. Caballero-Gaudes, César Neuroimage Article Performing a BOLD functional MRI (fMRI) acquisition during breath-hold (BH) tasks is a non-invasive, robust method to estimate cerebrovascular reactivity (CVR). However, movement and breathing-related artefacts caused by the BH can substantially hinder CVR estimates due to their high temporal collinearity with the effect of interest, and attention has to be paid when choosing which analysis model should be applied to the data. In this study, we evaluate the performance of multiple analysis strategies based on lagged general linear models applied on multi-echo BOLD fMRI data, acquired in ten subjects performing a BH task during ten sessions, to obtain subject-specific CVR and haemodynamic lag estimates. The evaluated approaches range from conventional regression models, i.e. including drifts and motion timecourses as nuisance regressors, applied on single-echo or optimally-combined data, to more complex models including regressors obtained from multi-echo independent component analysis with different grades of orthogonalization in order to preserve the effect of interest, i.e. the CVR. We compare these models in terms of their ability to make signal intensity changes independent from motion, as well as the reliability as measured by voxelwise intraclass correlation coefficients of both CVR and lag maps over time. Our results reveal that a conservative independent component analysis model applied on the optimally-combined multi-echo fMRI signal offers the largest reduction of motion-related effects in the signal, while yielding reliable CVR amplitude and lag estimates, although a conventional regression model applied on the optimally-combined data results in similar estimates. This work demonstrates the usefulness of multi-echo based fMRI acquisitions and independent component analysis denoising for precision mapping of CVR in single subjects based on BH paradigms, fostering its potential as a clinically-viable neuroimaging tool for individual patients. It also proves that the way in which data-driven regressors should be incorporated in the analysis model is not straight-forward due to their complex interaction with the BH-induced BOLD response. 2021-03-06 2021-06 /pmc/articles/PMC8351526/ /pubmed/33684602 http://dx.doi.org/10.1016/j.neuroimage.2021.117914 Text en https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) )
spellingShingle Article
Moia, Stefano
Termenon, Maite
Uruñuela, Eneko
Chen, Gang
Stickland, Rachael C.
Bright, Molly G.
Caballero-Gaudes, César
ICA-based denoising strategies in breath-hold induced cerebrovascular reactivity mapping with multi echo BOLD fMRI
title ICA-based denoising strategies in breath-hold induced cerebrovascular reactivity mapping with multi echo BOLD fMRI
title_full ICA-based denoising strategies in breath-hold induced cerebrovascular reactivity mapping with multi echo BOLD fMRI
title_fullStr ICA-based denoising strategies in breath-hold induced cerebrovascular reactivity mapping with multi echo BOLD fMRI
title_full_unstemmed ICA-based denoising strategies in breath-hold induced cerebrovascular reactivity mapping with multi echo BOLD fMRI
title_short ICA-based denoising strategies in breath-hold induced cerebrovascular reactivity mapping with multi echo BOLD fMRI
title_sort ica-based denoising strategies in breath-hold induced cerebrovascular reactivity mapping with multi echo bold fmri
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8351526/
https://www.ncbi.nlm.nih.gov/pubmed/33684602
http://dx.doi.org/10.1016/j.neuroimage.2021.117914
work_keys_str_mv AT moiastefano icabaseddenoisingstrategiesinbreathholdinducedcerebrovascularreactivitymappingwithmultiechoboldfmri
AT termenonmaite icabaseddenoisingstrategiesinbreathholdinducedcerebrovascularreactivitymappingwithmultiechoboldfmri
AT urunuelaeneko icabaseddenoisingstrategiesinbreathholdinducedcerebrovascularreactivitymappingwithmultiechoboldfmri
AT chengang icabaseddenoisingstrategiesinbreathholdinducedcerebrovascularreactivitymappingwithmultiechoboldfmri
AT sticklandrachaelc icabaseddenoisingstrategiesinbreathholdinducedcerebrovascularreactivitymappingwithmultiechoboldfmri
AT brightmollyg icabaseddenoisingstrategiesinbreathholdinducedcerebrovascularreactivitymappingwithmultiechoboldfmri
AT caballerogaudescesar icabaseddenoisingstrategiesinbreathholdinducedcerebrovascularreactivitymappingwithmultiechoboldfmri