Cargando…
Microstructural, microchemical, and mechanical changes associated with the clinical reuse of two nickel–titanium endodontic instruments
BACKGROUND: Nickel–titanium (NiTi) instruments have represented a great technological development that enabled endodontists conforming irregular-shaped root canals. Notwithstanding, the repeated use of these instruments may lead to the fracture without any prior visible warning signs. This study aim...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8351959/ https://www.ncbi.nlm.nih.gov/pubmed/34429868 |
_version_ | 1783736080351100928 |
---|---|
author | Restrepo-Restrepo, Felipe Augusto Holguín-Vásquez, Viviana Andrea Cañas-Jiménez, Syldana Julieth Villa-Machado, Paula Andrea Ochoa-Soto, Sara Ossa-Orozco, Claudia Patricia Tobón-Arroyave, Sergio Iván |
author_facet | Restrepo-Restrepo, Felipe Augusto Holguín-Vásquez, Viviana Andrea Cañas-Jiménez, Syldana Julieth Villa-Machado, Paula Andrea Ochoa-Soto, Sara Ossa-Orozco, Claudia Patricia Tobón-Arroyave, Sergio Iván |
author_sort | Restrepo-Restrepo, Felipe Augusto |
collection | PubMed |
description | BACKGROUND: Nickel–titanium (NiTi) instruments have represented a great technological development that enabled endodontists conforming irregular-shaped root canals. Notwithstanding, the repeated use of these instruments may lead to the fracture without any prior visible warning signs. This study aimed to evaluate how multiple clinical instrumentation/sterilization cycles of two NiTi mechanized instruments can affect their microstructural, microchemical, and mechanical characteristics. MATERIALS AND METHODS: In this observational descriptive study, a total of 140 NiTi instruments, 70 ProTaper Gold(®) (PTG) and 70 WaveOne Gold(®) (WOG) were analyzed. For each brand system, instruments were evaluated in the as-received condition (n = 10) and after one (n = 20), two (n = 20), and three (n = 20) instrumentation/sterilization cycles. Intraoperative instrumentation parameters were recorded for all used instruments. Afterward, the files were examined using scanning electron microscopy and energy-dispersive X-ray microanalysis. All of the instruments were tensile-fatigue tested until rupture in order to calculate the mechanical tensile strength and the maximum elongation percentage for the samples. Statistical analysis was completed using Chi-square, Kruskal–Wallis H-, or Mann–Whitney U-tests with a statistical significance set at P < 0.05. RESULTS: Significant increasing changes in surface topography (P < 0.05, Chi-square test) and chemical composition (P < 0.05, Kruskal–Wallis H-test) in both brand systems through instrumentation/sterilization cycles were detected. In addition, values of mechanical tensile strength and maximum elongation percentage increased significantly through instrumentation/sterilization cycles in the PTG group, whereas only the median values of mechanical tensile strength increased significantly in the WOG group (all P < 0.01, Kruskal–Wallis H-test). CONCLUSION: Although multiple instrumentation/sterilization cycles may render NiTi instruments more flexible and fatigue resistant, the significant changes detected in their surface topography and chemical composition should preclude their repeated clinical use in the routine endodontic practice as prevention for breakage. |
format | Online Article Text |
id | pubmed-8351959 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-83519592021-08-23 Microstructural, microchemical, and mechanical changes associated with the clinical reuse of two nickel–titanium endodontic instruments Restrepo-Restrepo, Felipe Augusto Holguín-Vásquez, Viviana Andrea Cañas-Jiménez, Syldana Julieth Villa-Machado, Paula Andrea Ochoa-Soto, Sara Ossa-Orozco, Claudia Patricia Tobón-Arroyave, Sergio Iván Dent Res J (Isfahan) Original Article BACKGROUND: Nickel–titanium (NiTi) instruments have represented a great technological development that enabled endodontists conforming irregular-shaped root canals. Notwithstanding, the repeated use of these instruments may lead to the fracture without any prior visible warning signs. This study aimed to evaluate how multiple clinical instrumentation/sterilization cycles of two NiTi mechanized instruments can affect their microstructural, microchemical, and mechanical characteristics. MATERIALS AND METHODS: In this observational descriptive study, a total of 140 NiTi instruments, 70 ProTaper Gold(®) (PTG) and 70 WaveOne Gold(®) (WOG) were analyzed. For each brand system, instruments were evaluated in the as-received condition (n = 10) and after one (n = 20), two (n = 20), and three (n = 20) instrumentation/sterilization cycles. Intraoperative instrumentation parameters were recorded for all used instruments. Afterward, the files were examined using scanning electron microscopy and energy-dispersive X-ray microanalysis. All of the instruments were tensile-fatigue tested until rupture in order to calculate the mechanical tensile strength and the maximum elongation percentage for the samples. Statistical analysis was completed using Chi-square, Kruskal–Wallis H-, or Mann–Whitney U-tests with a statistical significance set at P < 0.05. RESULTS: Significant increasing changes in surface topography (P < 0.05, Chi-square test) and chemical composition (P < 0.05, Kruskal–Wallis H-test) in both brand systems through instrumentation/sterilization cycles were detected. In addition, values of mechanical tensile strength and maximum elongation percentage increased significantly through instrumentation/sterilization cycles in the PTG group, whereas only the median values of mechanical tensile strength increased significantly in the WOG group (all P < 0.01, Kruskal–Wallis H-test). CONCLUSION: Although multiple instrumentation/sterilization cycles may render NiTi instruments more flexible and fatigue resistant, the significant changes detected in their surface topography and chemical composition should preclude their repeated clinical use in the routine endodontic practice as prevention for breakage. Wolters Kluwer - Medknow 2021-06-22 /pmc/articles/PMC8351959/ /pubmed/34429868 Text en Copyright: © 2021 Dental Research Journal https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Restrepo-Restrepo, Felipe Augusto Holguín-Vásquez, Viviana Andrea Cañas-Jiménez, Syldana Julieth Villa-Machado, Paula Andrea Ochoa-Soto, Sara Ossa-Orozco, Claudia Patricia Tobón-Arroyave, Sergio Iván Microstructural, microchemical, and mechanical changes associated with the clinical reuse of two nickel–titanium endodontic instruments |
title | Microstructural, microchemical, and mechanical changes associated with the clinical reuse of two nickel–titanium endodontic instruments |
title_full | Microstructural, microchemical, and mechanical changes associated with the clinical reuse of two nickel–titanium endodontic instruments |
title_fullStr | Microstructural, microchemical, and mechanical changes associated with the clinical reuse of two nickel–titanium endodontic instruments |
title_full_unstemmed | Microstructural, microchemical, and mechanical changes associated with the clinical reuse of two nickel–titanium endodontic instruments |
title_short | Microstructural, microchemical, and mechanical changes associated with the clinical reuse of two nickel–titanium endodontic instruments |
title_sort | microstructural, microchemical, and mechanical changes associated with the clinical reuse of two nickel–titanium endodontic instruments |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8351959/ https://www.ncbi.nlm.nih.gov/pubmed/34429868 |
work_keys_str_mv | AT restreporestrepofelipeaugusto microstructuralmicrochemicalandmechanicalchangesassociatedwiththeclinicalreuseoftwonickeltitaniumendodonticinstruments AT holguinvasquezvivianaandrea microstructuralmicrochemicalandmechanicalchangesassociatedwiththeclinicalreuseoftwonickeltitaniumendodonticinstruments AT canasjimenezsyldanajulieth microstructuralmicrochemicalandmechanicalchangesassociatedwiththeclinicalreuseoftwonickeltitaniumendodonticinstruments AT villamachadopaulaandrea microstructuralmicrochemicalandmechanicalchangesassociatedwiththeclinicalreuseoftwonickeltitaniumendodonticinstruments AT ochoasotosara microstructuralmicrochemicalandmechanicalchangesassociatedwiththeclinicalreuseoftwonickeltitaniumendodonticinstruments AT ossaorozcoclaudiapatricia microstructuralmicrochemicalandmechanicalchangesassociatedwiththeclinicalreuseoftwonickeltitaniumendodonticinstruments AT tobonarroyavesergioivan microstructuralmicrochemicalandmechanicalchangesassociatedwiththeclinicalreuseoftwonickeltitaniumendodonticinstruments |