The „EPiQ“-Study (Evaluation of preanalytical quality): S-Monovette® in manual aspiration mode drastically reduces hemolytic samples in head-to-head study

BACKGROUND: Hemolytic blood samples are the number one cause for specimen rejection at emergency departments. Triggered by unsuitable blood sampling material or incorrect handling and a related strong vacuum force, hemolytic samples often must be retaken. The objective of this study was to assess wh...

Descripción completa

Detalles Bibliográficos
Autores principales: Millius, Laura, Riedo, Erwin, Caron, Thierry, Belissent, Juliette, Fellay, Benoît, Ribordy, Vincent, Magnin, Jean-Luc
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8353461/
https://www.ncbi.nlm.nih.gov/pubmed/34401434
http://dx.doi.org/10.1016/j.plabm.2021.e00252
_version_ 1783736411814363136
author Millius, Laura
Riedo, Erwin
Caron, Thierry
Belissent, Juliette
Fellay, Benoît
Ribordy, Vincent
Magnin, Jean-Luc
author_facet Millius, Laura
Riedo, Erwin
Caron, Thierry
Belissent, Juliette
Fellay, Benoît
Ribordy, Vincent
Magnin, Jean-Luc
author_sort Millius, Laura
collection PubMed
description BACKGROUND: Hemolytic blood samples are the number one cause for specimen rejection at emergency departments. Triggered by unsuitable blood sampling material or incorrect handling and a related strong vacuum force, hemolytic samples often must be retaken. The objective of this study was to assess whether correct manual aspiration using S-Monovette® could reduce the number of hemolytic samples. METHODS: Between January and April 2019, a head-to-head study was conducted. Whereas in the first eight weeks, all specimens were collected using Vacutainer®, in the second eight weeks, blood was taken using S-Monovette® in aspiration mode. Specimens were categorized into five classes (0–30, 31–50, 51–75, 76–100, and 101+ mg/dl of cell-free hemoglobin) and for the statistical analyses, all samples exceeding 30 mg/dl were classified as hemolytic. RESULTS: Data were collected on 4794 blood specimens (Vacutainer®: 2634 samples, S-Monovette®: 2160 samples). While the percentage of non-hemolytic samples (HI of 0–30 mg/dl) was substantially higher for specimens drawn by S-Monovette® (95.7 %) than Vacutainer® (83.0 %), the opposite was true for all HI categories above 30 mg/dl. Importantly, the reduction of hemolytic samples took place immediately following the imposition of S-Monovette® and remained stable at a low level until the end of the study. CONCLUSIONS: Based on our results, we conclude that switching to S-Monovette® in manual aspiration mode in the blood sampling process could be highly beneficial, not only from a financial point of view, but also with regards to reducing unnecessary tasks and stress for nursing staff and improving patient outcome overall.
format Online
Article
Text
id pubmed-8353461
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-83534612021-08-15 The „EPiQ“-Study (Evaluation of preanalytical quality): S-Monovette® in manual aspiration mode drastically reduces hemolytic samples in head-to-head study Millius, Laura Riedo, Erwin Caron, Thierry Belissent, Juliette Fellay, Benoît Ribordy, Vincent Magnin, Jean-Luc Pract Lab Med Article BACKGROUND: Hemolytic blood samples are the number one cause for specimen rejection at emergency departments. Triggered by unsuitable blood sampling material or incorrect handling and a related strong vacuum force, hemolytic samples often must be retaken. The objective of this study was to assess whether correct manual aspiration using S-Monovette® could reduce the number of hemolytic samples. METHODS: Between January and April 2019, a head-to-head study was conducted. Whereas in the first eight weeks, all specimens were collected using Vacutainer®, in the second eight weeks, blood was taken using S-Monovette® in aspiration mode. Specimens were categorized into five classes (0–30, 31–50, 51–75, 76–100, and 101+ mg/dl of cell-free hemoglobin) and for the statistical analyses, all samples exceeding 30 mg/dl were classified as hemolytic. RESULTS: Data were collected on 4794 blood specimens (Vacutainer®: 2634 samples, S-Monovette®: 2160 samples). While the percentage of non-hemolytic samples (HI of 0–30 mg/dl) was substantially higher for specimens drawn by S-Monovette® (95.7 %) than Vacutainer® (83.0 %), the opposite was true for all HI categories above 30 mg/dl. Importantly, the reduction of hemolytic samples took place immediately following the imposition of S-Monovette® and remained stable at a low level until the end of the study. CONCLUSIONS: Based on our results, we conclude that switching to S-Monovette® in manual aspiration mode in the blood sampling process could be highly beneficial, not only from a financial point of view, but also with regards to reducing unnecessary tasks and stress for nursing staff and improving patient outcome overall. Elsevier 2021-07-28 /pmc/articles/PMC8353461/ /pubmed/34401434 http://dx.doi.org/10.1016/j.plabm.2021.e00252 Text en © 2021 Published by Elsevier B.V. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Article
Millius, Laura
Riedo, Erwin
Caron, Thierry
Belissent, Juliette
Fellay, Benoît
Ribordy, Vincent
Magnin, Jean-Luc
The „EPiQ“-Study (Evaluation of preanalytical quality): S-Monovette® in manual aspiration mode drastically reduces hemolytic samples in head-to-head study
title The „EPiQ“-Study (Evaluation of preanalytical quality): S-Monovette® in manual aspiration mode drastically reduces hemolytic samples in head-to-head study
title_full The „EPiQ“-Study (Evaluation of preanalytical quality): S-Monovette® in manual aspiration mode drastically reduces hemolytic samples in head-to-head study
title_fullStr The „EPiQ“-Study (Evaluation of preanalytical quality): S-Monovette® in manual aspiration mode drastically reduces hemolytic samples in head-to-head study
title_full_unstemmed The „EPiQ“-Study (Evaluation of preanalytical quality): S-Monovette® in manual aspiration mode drastically reduces hemolytic samples in head-to-head study
title_short The „EPiQ“-Study (Evaluation of preanalytical quality): S-Monovette® in manual aspiration mode drastically reduces hemolytic samples in head-to-head study
title_sort „epiq“-study (evaluation of preanalytical quality): s-monovette® in manual aspiration mode drastically reduces hemolytic samples in head-to-head study
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8353461/
https://www.ncbi.nlm.nih.gov/pubmed/34401434
http://dx.doi.org/10.1016/j.plabm.2021.e00252
work_keys_str_mv AT milliuslaura theepiqstudyevaluationofpreanalyticalqualitysmonovetteinmanualaspirationmodedrasticallyreduceshemolyticsamplesinheadtoheadstudy
AT riedoerwin theepiqstudyevaluationofpreanalyticalqualitysmonovetteinmanualaspirationmodedrasticallyreduceshemolyticsamplesinheadtoheadstudy
AT caronthierry theepiqstudyevaluationofpreanalyticalqualitysmonovetteinmanualaspirationmodedrasticallyreduceshemolyticsamplesinheadtoheadstudy
AT belissentjuliette theepiqstudyevaluationofpreanalyticalqualitysmonovetteinmanualaspirationmodedrasticallyreduceshemolyticsamplesinheadtoheadstudy
AT fellaybenoit theepiqstudyevaluationofpreanalyticalqualitysmonovetteinmanualaspirationmodedrasticallyreduceshemolyticsamplesinheadtoheadstudy
AT ribordyvincent theepiqstudyevaluationofpreanalyticalqualitysmonovetteinmanualaspirationmodedrasticallyreduceshemolyticsamplesinheadtoheadstudy
AT magninjeanluc theepiqstudyevaluationofpreanalyticalqualitysmonovetteinmanualaspirationmodedrasticallyreduceshemolyticsamplesinheadtoheadstudy
AT milliuslaura epiqstudyevaluationofpreanalyticalqualitysmonovetteinmanualaspirationmodedrasticallyreduceshemolyticsamplesinheadtoheadstudy
AT riedoerwin epiqstudyevaluationofpreanalyticalqualitysmonovetteinmanualaspirationmodedrasticallyreduceshemolyticsamplesinheadtoheadstudy
AT caronthierry epiqstudyevaluationofpreanalyticalqualitysmonovetteinmanualaspirationmodedrasticallyreduceshemolyticsamplesinheadtoheadstudy
AT belissentjuliette epiqstudyevaluationofpreanalyticalqualitysmonovetteinmanualaspirationmodedrasticallyreduceshemolyticsamplesinheadtoheadstudy
AT fellaybenoit epiqstudyevaluationofpreanalyticalqualitysmonovetteinmanualaspirationmodedrasticallyreduceshemolyticsamplesinheadtoheadstudy
AT ribordyvincent epiqstudyevaluationofpreanalyticalqualitysmonovetteinmanualaspirationmodedrasticallyreduceshemolyticsamplesinheadtoheadstudy
AT magninjeanluc epiqstudyevaluationofpreanalyticalqualitysmonovetteinmanualaspirationmodedrasticallyreduceshemolyticsamplesinheadtoheadstudy