Cargando…

Biocompatibility and Osseointegration of Calcium Phosphate-Coated and Non-Coated Titanium Implants with Various Porosities

The aim of the investigation was to study the influence of pore size and the presence of a biologically active calcium phosphate coating in porous 3D printed titanium implants on the process of integration with the bone tissue. MATERIALS AND METHODS: Samples of cylindrical implants with three differ...

Descripción completa

Detalles Bibliográficos
Autores principales: Korytkin, A.A., Orlinskaya, N.Yu., Novikova, Ya.S., Gerasimov, S.A., Davydenko, D.V., Kulakova, K.V., Tverdokhlebov, S.I., Bolbasov, E.N.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Privolzhsky Research Medical University 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8353716/
https://www.ncbi.nlm.nih.gov/pubmed/34513077
http://dx.doi.org/10.17691/stm2021.13.2.06
_version_ 1783736460393840640
author Korytkin, A.A.
Orlinskaya, N.Yu.
Novikova, Ya.S.
Gerasimov, S.A.
Davydenko, D.V.
Kulakova, K.V.
Tverdokhlebov, S.I.
Bolbasov, E.N.
author_facet Korytkin, A.A.
Orlinskaya, N.Yu.
Novikova, Ya.S.
Gerasimov, S.A.
Davydenko, D.V.
Kulakova, K.V.
Tverdokhlebov, S.I.
Bolbasov, E.N.
author_sort Korytkin, A.A.
collection PubMed
description The aim of the investigation was to study the influence of pore size and the presence of a biologically active calcium phosphate coating in porous 3D printed titanium implants on the process of integration with the bone tissue. MATERIALS AND METHODS: Samples of cylindrical implants with three different pore diameters (100, 200, and 400 μm) were fabricated from titanium powder on the Arcam 3D printer (Sweden) using electron beam melting technology. A calcium phosphate coating with a thickness of 20±4 μm was applied to some of the products by microarc oxidation. Cytotoxicity of the implants was determined in vitro on human dermal fibroblast cultures. The samples were implanted in the femoral bones of 36 rabbits in vivo. The animals were divided into 6 groups according to the bone implant samples. The prepared samples and peri-implant tissues were studied on days 90 and 180 after implantation using scanning electron microscopy and histological methods. RESULTS: All samples under study were found to be non-toxic and well biocompatible with the bone tissue. There were revealed no differences between coated and non-coated implants of 100 and 200 μm pore diameters in terms of their histological structure, intensity of vascularization in the early stages, and bone formation in the later stages. Samples with pore diameters of 100 and 200 μm were easily removed from the bone tissue, the depth of bone growth into the pores of the implant was lower than in the samples with pore diameter of 400 μm (p<0.001). There were differences between coated and non-coated samples of 400 μm pore diameter, which was expressed in a more intensive osseointegration of samples with calcium phosphate coating (p<0.05). CONCLUSION: The optimal surface characteristics of the material for repairing bone defects are a pore diameter of 400 μm and the presence of a calcium phosphate coating.
format Online
Article
Text
id pubmed-8353716
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Privolzhsky Research Medical University
record_format MEDLINE/PubMed
spelling pubmed-83537162021-09-09 Biocompatibility and Osseointegration of Calcium Phosphate-Coated and Non-Coated Titanium Implants with Various Porosities Korytkin, A.A. Orlinskaya, N.Yu. Novikova, Ya.S. Gerasimov, S.A. Davydenko, D.V. Kulakova, K.V. Tverdokhlebov, S.I. Bolbasov, E.N. Sovrem Tekhnologii Med Biotechnologies The aim of the investigation was to study the influence of pore size and the presence of a biologically active calcium phosphate coating in porous 3D printed titanium implants on the process of integration with the bone tissue. MATERIALS AND METHODS: Samples of cylindrical implants with three different pore diameters (100, 200, and 400 μm) were fabricated from titanium powder on the Arcam 3D printer (Sweden) using electron beam melting technology. A calcium phosphate coating with a thickness of 20±4 μm was applied to some of the products by microarc oxidation. Cytotoxicity of the implants was determined in vitro on human dermal fibroblast cultures. The samples were implanted in the femoral bones of 36 rabbits in vivo. The animals were divided into 6 groups according to the bone implant samples. The prepared samples and peri-implant tissues were studied on days 90 and 180 after implantation using scanning electron microscopy and histological methods. RESULTS: All samples under study were found to be non-toxic and well biocompatible with the bone tissue. There were revealed no differences between coated and non-coated implants of 100 and 200 μm pore diameters in terms of their histological structure, intensity of vascularization in the early stages, and bone formation in the later stages. Samples with pore diameters of 100 and 200 μm were easily removed from the bone tissue, the depth of bone growth into the pores of the implant was lower than in the samples with pore diameter of 400 μm (p<0.001). There were differences between coated and non-coated samples of 400 μm pore diameter, which was expressed in a more intensive osseointegration of samples with calcium phosphate coating (p<0.05). CONCLUSION: The optimal surface characteristics of the material for repairing bone defects are a pore diameter of 400 μm and the presence of a calcium phosphate coating. Privolzhsky Research Medical University 2021 2021-01-01 /pmc/articles/PMC8353716/ /pubmed/34513077 http://dx.doi.org/10.17691/stm2021.13.2.06 Text en https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY 4.0 license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Biotechnologies
Korytkin, A.A.
Orlinskaya, N.Yu.
Novikova, Ya.S.
Gerasimov, S.A.
Davydenko, D.V.
Kulakova, K.V.
Tverdokhlebov, S.I.
Bolbasov, E.N.
Biocompatibility and Osseointegration of Calcium Phosphate-Coated and Non-Coated Titanium Implants with Various Porosities
title Biocompatibility and Osseointegration of Calcium Phosphate-Coated and Non-Coated Titanium Implants with Various Porosities
title_full Biocompatibility and Osseointegration of Calcium Phosphate-Coated and Non-Coated Titanium Implants with Various Porosities
title_fullStr Biocompatibility and Osseointegration of Calcium Phosphate-Coated and Non-Coated Titanium Implants with Various Porosities
title_full_unstemmed Biocompatibility and Osseointegration of Calcium Phosphate-Coated and Non-Coated Titanium Implants with Various Porosities
title_short Biocompatibility and Osseointegration of Calcium Phosphate-Coated and Non-Coated Titanium Implants with Various Porosities
title_sort biocompatibility and osseointegration of calcium phosphate-coated and non-coated titanium implants with various porosities
topic Biotechnologies
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8353716/
https://www.ncbi.nlm.nih.gov/pubmed/34513077
http://dx.doi.org/10.17691/stm2021.13.2.06
work_keys_str_mv AT korytkinaa biocompatibilityandosseointegrationofcalciumphosphatecoatedandnoncoatedtitaniumimplantswithvariousporosities
AT orlinskayanyu biocompatibilityandosseointegrationofcalciumphosphatecoatedandnoncoatedtitaniumimplantswithvariousporosities
AT novikovayas biocompatibilityandosseointegrationofcalciumphosphatecoatedandnoncoatedtitaniumimplantswithvariousporosities
AT gerasimovsa biocompatibilityandosseointegrationofcalciumphosphatecoatedandnoncoatedtitaniumimplantswithvariousporosities
AT davydenkodv biocompatibilityandosseointegrationofcalciumphosphatecoatedandnoncoatedtitaniumimplantswithvariousporosities
AT kulakovakv biocompatibilityandosseointegrationofcalciumphosphatecoatedandnoncoatedtitaniumimplantswithvariousporosities
AT tverdokhlebovsi biocompatibilityandosseointegrationofcalciumphosphatecoatedandnoncoatedtitaniumimplantswithvariousporosities
AT bolbasoven biocompatibilityandosseointegrationofcalciumphosphatecoatedandnoncoatedtitaniumimplantswithvariousporosities