Cargando…
Peanut components measured by ISAC: comparison with ImmunoCap and clinical relevance in peanut allergic children
BACKGROUND: Specific IgE (sIgE) against the peanut component Arachis hypogaea (Ara h) 2 has been shown to be the most important allergen to discriminate between peanut allergy and peanut tolerance. Several studies determined sIgE cut off values for Ara h 2, determined by singleplex measurements. How...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8353733/ https://www.ncbi.nlm.nih.gov/pubmed/34372856 http://dx.doi.org/10.1186/s12948-021-00153-w |
_version_ | 1783736463916007424 |
---|---|
author | Brand, H. K. Schreurs, M. W. J. Emons, J. A. M. Gerth van Wijk, R. de Groot, H. Arends, N. J. T. |
author_facet | Brand, H. K. Schreurs, M. W. J. Emons, J. A. M. Gerth van Wijk, R. de Groot, H. Arends, N. J. T. |
author_sort | Brand, H. K. |
collection | PubMed |
description | BACKGROUND: Specific IgE (sIgE) against the peanut component Arachis hypogaea (Ara h) 2 has been shown to be the most important allergen to discriminate between peanut allergy and peanut tolerance. Several studies determined sIgE cut off values for Ara h 2, determined by singleplex measurements. However, cut off values for Ara h 2 from multiplex arrays are less well defined. The aim of this study was to evaluate the correlation between Ara h 2 sIgE determined by singleplex versus multiplex measurements and to assess the diagnostic value of the different peanut components included in Immuno Solid-phase Allergen Chip (ISAC) multiplex analysis in children with a suspected peanut allergy. METHODS: In this retrospective study we analyzed Ara h 2 sIgE values with singleplex Fluorescence Enzyme Immunoassay (FEIA, ImmunoCap) and multiplex microarray (ISAC) measurements in 117 children with a suspected peanut allergy. Also, other peanut components measured by ISAC were analyzed. Double blinded placebo controlled oral food challenges were used as golden standard. RESULTS: Among all studied peanut components FEIA Ara h 2 sIgE showed the highest area under the curve (AUC, 0.922), followed by ISAC Ara h 6 and Ara h 2 sIgE with AUCs of respectively 0.906 and 0.902. Best cut off values to diagnose peanut allergy were 4.40 kU/l for FEIA Ara h 2 sIgE and, 7.43 ISU and 8.13 ISU for respectively Ara h 2 and Ara h 6 sIgE in ISAC microarray. Ara h 2 sIgE determined in FEIA and ISAC showed a good correlation (r = 0.88; p < 0.01). CONCLUSION: Ara h 6 and Ara h 2 sIgE in multiplex ISAC are both good predictors of clinical peanut allergy in Dutch children, and their performance is comparable to the use of Ara h 2 in singleplex FEIA. The simultaneous measurement of different peanut components using ISAC is an advantage and clinically useful to detect peanut allergic children that are Ara h 2 negative but sensitized to other peanut proteins such as Ara h 6. |
format | Online Article Text |
id | pubmed-8353733 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-83537332021-08-10 Peanut components measured by ISAC: comparison with ImmunoCap and clinical relevance in peanut allergic children Brand, H. K. Schreurs, M. W. J. Emons, J. A. M. Gerth van Wijk, R. de Groot, H. Arends, N. J. T. Clin Mol Allergy Research BACKGROUND: Specific IgE (sIgE) against the peanut component Arachis hypogaea (Ara h) 2 has been shown to be the most important allergen to discriminate between peanut allergy and peanut tolerance. Several studies determined sIgE cut off values for Ara h 2, determined by singleplex measurements. However, cut off values for Ara h 2 from multiplex arrays are less well defined. The aim of this study was to evaluate the correlation between Ara h 2 sIgE determined by singleplex versus multiplex measurements and to assess the diagnostic value of the different peanut components included in Immuno Solid-phase Allergen Chip (ISAC) multiplex analysis in children with a suspected peanut allergy. METHODS: In this retrospective study we analyzed Ara h 2 sIgE values with singleplex Fluorescence Enzyme Immunoassay (FEIA, ImmunoCap) and multiplex microarray (ISAC) measurements in 117 children with a suspected peanut allergy. Also, other peanut components measured by ISAC were analyzed. Double blinded placebo controlled oral food challenges were used as golden standard. RESULTS: Among all studied peanut components FEIA Ara h 2 sIgE showed the highest area under the curve (AUC, 0.922), followed by ISAC Ara h 6 and Ara h 2 sIgE with AUCs of respectively 0.906 and 0.902. Best cut off values to diagnose peanut allergy were 4.40 kU/l for FEIA Ara h 2 sIgE and, 7.43 ISU and 8.13 ISU for respectively Ara h 2 and Ara h 6 sIgE in ISAC microarray. Ara h 2 sIgE determined in FEIA and ISAC showed a good correlation (r = 0.88; p < 0.01). CONCLUSION: Ara h 6 and Ara h 2 sIgE in multiplex ISAC are both good predictors of clinical peanut allergy in Dutch children, and their performance is comparable to the use of Ara h 2 in singleplex FEIA. The simultaneous measurement of different peanut components using ISAC is an advantage and clinically useful to detect peanut allergic children that are Ara h 2 negative but sensitized to other peanut proteins such as Ara h 6. BioMed Central 2021-08-09 /pmc/articles/PMC8353733/ /pubmed/34372856 http://dx.doi.org/10.1186/s12948-021-00153-w Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Brand, H. K. Schreurs, M. W. J. Emons, J. A. M. Gerth van Wijk, R. de Groot, H. Arends, N. J. T. Peanut components measured by ISAC: comparison with ImmunoCap and clinical relevance in peanut allergic children |
title | Peanut components measured by ISAC: comparison with ImmunoCap and clinical relevance in peanut allergic children |
title_full | Peanut components measured by ISAC: comparison with ImmunoCap and clinical relevance in peanut allergic children |
title_fullStr | Peanut components measured by ISAC: comparison with ImmunoCap and clinical relevance in peanut allergic children |
title_full_unstemmed | Peanut components measured by ISAC: comparison with ImmunoCap and clinical relevance in peanut allergic children |
title_short | Peanut components measured by ISAC: comparison with ImmunoCap and clinical relevance in peanut allergic children |
title_sort | peanut components measured by isac: comparison with immunocap and clinical relevance in peanut allergic children |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8353733/ https://www.ncbi.nlm.nih.gov/pubmed/34372856 http://dx.doi.org/10.1186/s12948-021-00153-w |
work_keys_str_mv | AT brandhk peanutcomponentsmeasuredbyisaccomparisonwithimmunocapandclinicalrelevanceinpeanutallergicchildren AT schreursmwj peanutcomponentsmeasuredbyisaccomparisonwithimmunocapandclinicalrelevanceinpeanutallergicchildren AT emonsjam peanutcomponentsmeasuredbyisaccomparisonwithimmunocapandclinicalrelevanceinpeanutallergicchildren AT gerthvanwijkr peanutcomponentsmeasuredbyisaccomparisonwithimmunocapandclinicalrelevanceinpeanutallergicchildren AT degrooth peanutcomponentsmeasuredbyisaccomparisonwithimmunocapandclinicalrelevanceinpeanutallergicchildren AT arendsnjt peanutcomponentsmeasuredbyisaccomparisonwithimmunocapandclinicalrelevanceinpeanutallergicchildren |