Cargando…

Comparison of efficacy, safety & satisfaction of intermittent versus continuous phototherapy in hyperbilirubinaemic newborns ≥35 week gestation: A randomized controlled trial

BACKGROUND & OBJECTIVES: Phototherapy (PT) has become the standard of care for treating neonatal jaundice. This study was aimed to find out if intermittent PT (IPT) results in comparable rate of fall of bilirubin level to continuous PT (CPT) and results in lesser side effects and better acceptan...

Descripción completa

Detalles Bibliográficos
Autores principales: Gottimukkala, Sasi Bhushan, Sethuraman, Giridhar, Kitchanan, Srinivasan, Pathak, Surajit
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8354053/
https://www.ncbi.nlm.nih.gov/pubmed/34380790
http://dx.doi.org/10.4103/ijmr.IJMR_2156_18
_version_ 1783736524270993408
author Gottimukkala, Sasi Bhushan
Sethuraman, Giridhar
Kitchanan, Srinivasan
Pathak, Surajit
author_facet Gottimukkala, Sasi Bhushan
Sethuraman, Giridhar
Kitchanan, Srinivasan
Pathak, Surajit
author_sort Gottimukkala, Sasi Bhushan
collection PubMed
description BACKGROUND & OBJECTIVES: Phototherapy (PT) has become the standard of care for treating neonatal jaundice. This study was aimed to find out if intermittent PT (IPT) results in comparable rate of fall of bilirubin level to continuous PT (CPT) and results in lesser side effects and better acceptance. METHODS: In this non-inferiority trial, 174 neonates ≥35 wk gestation and >2000 g with jaundice requiring PT were randomized to receive either IPT (one hour on and two hours off) or CPT (with minimum interruptions for feeding) after device stratification [light-emitting diode (LED) or compact fluorescent light (CFL)]. Bilirubin was checked 12(th) hourly, and calcium, vitamin D and nitric oxide (NO) levels were analyzed along with the clinical side effects and nursing and maternal satisfaction scores (CTRI Registration No. CTRI/2018/01/011072). RESULTS: The rate of fall of bilirubin was similar in both the CPT and IPT groups [0.16 (0.10, 0.22) vs. 0.13 (0.09, 0.20) mg/dl/h, P=0.22]. The median difference with 95 per cent confidence interval of 0.03 (0.03, 0.03) mg/dl was also within the pre-defined inferiority limits. There was no significant change in the duration of PT and side effects such as fall in calcium levels, rise in vitamin D and NO levels or the clinical side effects. Maternal satisfaction favoured the IPT group, but the nurses opined that IPT was difficult to implement. Subgroup analysis for PT devices used showed that efficacy of both CFL and LED devices was equivalent. INTERPRETATION & CONCLUSIONS: IPT was non-inferior to CPT in reducing bilirubin levels in ≥35 wk neonates, irrespective of device used, and also mothers reported better satisfaction with IPT. Although IPT appears promising, CPT does not increase clinical and biochemical side effects compared to IPT.
format Online
Article
Text
id pubmed-8354053
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-83540532021-08-23 Comparison of efficacy, safety & satisfaction of intermittent versus continuous phototherapy in hyperbilirubinaemic newborns ≥35 week gestation: A randomized controlled trial Gottimukkala, Sasi Bhushan Sethuraman, Giridhar Kitchanan, Srinivasan Pathak, Surajit Indian J Med Res Original Article BACKGROUND & OBJECTIVES: Phototherapy (PT) has become the standard of care for treating neonatal jaundice. This study was aimed to find out if intermittent PT (IPT) results in comparable rate of fall of bilirubin level to continuous PT (CPT) and results in lesser side effects and better acceptance. METHODS: In this non-inferiority trial, 174 neonates ≥35 wk gestation and >2000 g with jaundice requiring PT were randomized to receive either IPT (one hour on and two hours off) or CPT (with minimum interruptions for feeding) after device stratification [light-emitting diode (LED) or compact fluorescent light (CFL)]. Bilirubin was checked 12(th) hourly, and calcium, vitamin D and nitric oxide (NO) levels were analyzed along with the clinical side effects and nursing and maternal satisfaction scores (CTRI Registration No. CTRI/2018/01/011072). RESULTS: The rate of fall of bilirubin was similar in both the CPT and IPT groups [0.16 (0.10, 0.22) vs. 0.13 (0.09, 0.20) mg/dl/h, P=0.22]. The median difference with 95 per cent confidence interval of 0.03 (0.03, 0.03) mg/dl was also within the pre-defined inferiority limits. There was no significant change in the duration of PT and side effects such as fall in calcium levels, rise in vitamin D and NO levels or the clinical side effects. Maternal satisfaction favoured the IPT group, but the nurses opined that IPT was difficult to implement. Subgroup analysis for PT devices used showed that efficacy of both CFL and LED devices was equivalent. INTERPRETATION & CONCLUSIONS: IPT was non-inferior to CPT in reducing bilirubin levels in ≥35 wk neonates, irrespective of device used, and also mothers reported better satisfaction with IPT. Although IPT appears promising, CPT does not increase clinical and biochemical side effects compared to IPT. Wolters Kluwer - Medknow 2021-04 /pmc/articles/PMC8354053/ /pubmed/34380790 http://dx.doi.org/10.4103/ijmr.IJMR_2156_18 Text en Copyright: © 2021 Indian Journal of Medical Research https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Gottimukkala, Sasi Bhushan
Sethuraman, Giridhar
Kitchanan, Srinivasan
Pathak, Surajit
Comparison of efficacy, safety & satisfaction of intermittent versus continuous phototherapy in hyperbilirubinaemic newborns ≥35 week gestation: A randomized controlled trial
title Comparison of efficacy, safety & satisfaction of intermittent versus continuous phototherapy in hyperbilirubinaemic newborns ≥35 week gestation: A randomized controlled trial
title_full Comparison of efficacy, safety & satisfaction of intermittent versus continuous phototherapy in hyperbilirubinaemic newborns ≥35 week gestation: A randomized controlled trial
title_fullStr Comparison of efficacy, safety & satisfaction of intermittent versus continuous phototherapy in hyperbilirubinaemic newborns ≥35 week gestation: A randomized controlled trial
title_full_unstemmed Comparison of efficacy, safety & satisfaction of intermittent versus continuous phototherapy in hyperbilirubinaemic newborns ≥35 week gestation: A randomized controlled trial
title_short Comparison of efficacy, safety & satisfaction of intermittent versus continuous phototherapy in hyperbilirubinaemic newborns ≥35 week gestation: A randomized controlled trial
title_sort comparison of efficacy, safety & satisfaction of intermittent versus continuous phototherapy in hyperbilirubinaemic newborns ≥35 week gestation: a randomized controlled trial
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8354053/
https://www.ncbi.nlm.nih.gov/pubmed/34380790
http://dx.doi.org/10.4103/ijmr.IJMR_2156_18
work_keys_str_mv AT gottimukkalasasibhushan comparisonofefficacysafetysatisfactionofintermittentversuscontinuousphototherapyinhyperbilirubinaemicnewborns35weekgestationarandomizedcontrolledtrial
AT sethuramangiridhar comparisonofefficacysafetysatisfactionofintermittentversuscontinuousphototherapyinhyperbilirubinaemicnewborns35weekgestationarandomizedcontrolledtrial
AT kitchanansrinivasan comparisonofefficacysafetysatisfactionofintermittentversuscontinuousphototherapyinhyperbilirubinaemicnewborns35weekgestationarandomizedcontrolledtrial
AT pathaksurajit comparisonofefficacysafetysatisfactionofintermittentversuscontinuousphototherapyinhyperbilirubinaemicnewborns35weekgestationarandomizedcontrolledtrial