Cargando…

Performance of antigen testing for diagnosis of COVID-19: a direct comparison of a lateral flow device to nucleic acid amplification based tests

OBJECTIVES: The gold standard for diagnosing an infection with SARS-CoV-2 is detection of viral RNA by nucleic acid amplification techniques. Test capacities, however, are limited. Therefore, numerous easy-to-use rapid antigen tests based on lateral flow technology have been developed. Manufacturer-...

Descripción completa

Detalles Bibliográficos
Autores principales: Kahn, Maria, Schuierer, Lukas, Bartenschlager, Christina, Zellmer, Stephan, Frey, Ramona, Freitag, Marie, Dhillon, Christine, Heier, Margit, Ebigbo, Alanna, Denzel, Christian, Temizel, Selin, Messmann, Helmut, Wehler, Markus, Hoffmann, Reinhard, Kling, Elisabeth, Römmele, Christoph
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8354301/
https://www.ncbi.nlm.nih.gov/pubmed/34376187
http://dx.doi.org/10.1186/s12879-021-06524-7
Descripción
Sumario:OBJECTIVES: The gold standard for diagnosing an infection with SARS-CoV-2 is detection of viral RNA by nucleic acid amplification techniques. Test capacities, however, are limited. Therefore, numerous easy-to-use rapid antigen tests based on lateral flow technology have been developed. Manufacturer-reported performance data seem convincing, but real-world data are missing. METHODS: We retrospectively analysed all prospectively collected antigen tests results performed between 23.06.2020 and 26.11.2020, generated by non-laboratory personnel at the point-of-care from oro- or nasopharyngeal swab samples at the University Hospital Augsburg and compared them to concomitantly (within 24 h.) generated results from molecular tests. RESULTS: For a total of 3630 antigen tests, 3110 NAAT results were available. Overall, sensitivity, specificity, NPV and PPV of antigen testing were 59.4%, 99.0%, 98.7% and 64.8%, respectively. Sensitivity and PPV were lower in asymptomatic patients (47.6% and 44.4%, respectively) and only slightly higher in patients with clinical symptoms (66.7% and 85.0%, respectively). Some samples with very low Ct-values (minimum Ct 13) were not detected by antigen testing. 31 false positive results occurred. ROC curve analysis showed that reducing the COI cut-off from 1, as suggested by the manufacturer, to 0.9 is optimal, albeit with an AUC of only 0.66. CONCLUSION: In real life, performance of lateral-flow-based antigen tests are well below the manufacturer's specifications, irrespective of patient’s symptoms. Their use for detection of individual patients infected with SARS-CoV2 should be discouraged. This does not preclude their usefulness in large-scale screening programs to reduce transmission events on a population-wide scale. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1186/s12879-021-06524-7.