The impact of 1/f activity and baseline correction on the results and interpretation of time-frequency analyses of EEG/MEG data: A cautionary tale

Typically, time-frequency analysis (TFA) of electrophysiological data is aimed at isolating narrowband signals (oscillatory activity) from broadband non-oscillatory (1/f) activity, so that changes in oscillatory activity resulting from experimental manipulations can be assessed. A widely used method...

Descripción completa

Detalles Bibliográficos
Autores principales: Gyurkovics, Máté, Clements, Grace M., Low, Kathy A., Fabiani, Monica, Gratton, Gabriele
Formato: Online Artículo Texto
Lenguaje:English
Publicado: 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8354524/
https://www.ncbi.nlm.nih.gov/pubmed/34048899
http://dx.doi.org/10.1016/j.neuroimage.2021.118192
_version_ 1783736611574382592
author Gyurkovics, Máté
Clements, Grace M.
Low, Kathy A.
Fabiani, Monica
Gratton, Gabriele
author_facet Gyurkovics, Máté
Clements, Grace M.
Low, Kathy A.
Fabiani, Monica
Gratton, Gabriele
author_sort Gyurkovics, Máté
collection PubMed
description Typically, time-frequency analysis (TFA) of electrophysiological data is aimed at isolating narrowband signals (oscillatory activity) from broadband non-oscillatory (1/f) activity, so that changes in oscillatory activity resulting from experimental manipulations can be assessed. A widely used method to do this is to convert the data to the decibel (dB) scale through baseline division and log transformation. This procedure assumes that, for each frequency, sources of power (i.e., oscillations and 1/f activity) scale by the same factor relative to the baseline (multiplicative model). This assumption may be incorrect when signal and noise are independent contributors to the power spectrum (additive model). Using resting-state EEG data from 80 participants, we found that the level of 1/f activity and alpha power are not positively correlated within participants, in line with the additive but not the multiplicative model. Then, to assess the effects of dB conversion on data that violate the multiplicativity assumption, we simulated a mixed design study with one between-subject (noise level, i.e., level of 1/f activity) and one within-subject (signal amplitude, i.e., amplitude of oscillatory activity added onto the background 1/f activity) factor. The effect size of the noise level × signal amplitude interaction was examined as a function of noise difference between groups, following dB conversion. Findings revealed that dB conversion led to the over- or under-estimation of the true interaction effect when groups differing in 1/f levels were compared, and it also led to the emergence of illusory interactions when none were present. This is because signal amplitude was systematically underestimated in the noisier compared to the less noisy group. Hence, we recommend testing whether the level of 1/f activity differs across groups or conditions and using multiple baseline correction strategies to validate results if it does. Such a situation may be particularly common in aging, developmental, or clinical studies.
format Online
Article
Text
id pubmed-8354524
institution National Center for Biotechnology Information
language English
publishDate 2021
record_format MEDLINE/PubMed
spelling pubmed-83545242021-08-15 The impact of 1/f activity and baseline correction on the results and interpretation of time-frequency analyses of EEG/MEG data: A cautionary tale Gyurkovics, Máté Clements, Grace M. Low, Kathy A. Fabiani, Monica Gratton, Gabriele Neuroimage Article Typically, time-frequency analysis (TFA) of electrophysiological data is aimed at isolating narrowband signals (oscillatory activity) from broadband non-oscillatory (1/f) activity, so that changes in oscillatory activity resulting from experimental manipulations can be assessed. A widely used method to do this is to convert the data to the decibel (dB) scale through baseline division and log transformation. This procedure assumes that, for each frequency, sources of power (i.e., oscillations and 1/f activity) scale by the same factor relative to the baseline (multiplicative model). This assumption may be incorrect when signal and noise are independent contributors to the power spectrum (additive model). Using resting-state EEG data from 80 participants, we found that the level of 1/f activity and alpha power are not positively correlated within participants, in line with the additive but not the multiplicative model. Then, to assess the effects of dB conversion on data that violate the multiplicativity assumption, we simulated a mixed design study with one between-subject (noise level, i.e., level of 1/f activity) and one within-subject (signal amplitude, i.e., amplitude of oscillatory activity added onto the background 1/f activity) factor. The effect size of the noise level × signal amplitude interaction was examined as a function of noise difference between groups, following dB conversion. Findings revealed that dB conversion led to the over- or under-estimation of the true interaction effect when groups differing in 1/f levels were compared, and it also led to the emergence of illusory interactions when none were present. This is because signal amplitude was systematically underestimated in the noisier compared to the less noisy group. Hence, we recommend testing whether the level of 1/f activity differs across groups or conditions and using multiple baseline correction strategies to validate results if it does. Such a situation may be particularly common in aging, developmental, or clinical studies. 2021-05-25 2021-08-15 /pmc/articles/PMC8354524/ /pubmed/34048899 http://dx.doi.org/10.1016/j.neuroimage.2021.118192 Text en https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/ (https://creativecommons.org/licenses/by-nc-nd/4.0/) )
spellingShingle Article
Gyurkovics, Máté
Clements, Grace M.
Low, Kathy A.
Fabiani, Monica
Gratton, Gabriele
The impact of 1/f activity and baseline correction on the results and interpretation of time-frequency analyses of EEG/MEG data: A cautionary tale
title The impact of 1/f activity and baseline correction on the results and interpretation of time-frequency analyses of EEG/MEG data: A cautionary tale
title_full The impact of 1/f activity and baseline correction on the results and interpretation of time-frequency analyses of EEG/MEG data: A cautionary tale
title_fullStr The impact of 1/f activity and baseline correction on the results and interpretation of time-frequency analyses of EEG/MEG data: A cautionary tale
title_full_unstemmed The impact of 1/f activity and baseline correction on the results and interpretation of time-frequency analyses of EEG/MEG data: A cautionary tale
title_short The impact of 1/f activity and baseline correction on the results and interpretation of time-frequency analyses of EEG/MEG data: A cautionary tale
title_sort impact of 1/f activity and baseline correction on the results and interpretation of time-frequency analyses of eeg/meg data: a cautionary tale
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8354524/
https://www.ncbi.nlm.nih.gov/pubmed/34048899
http://dx.doi.org/10.1016/j.neuroimage.2021.118192
work_keys_str_mv AT gyurkovicsmate theimpactof1factivityandbaselinecorrectionontheresultsandinterpretationoftimefrequencyanalysesofeegmegdataacautionarytale
AT clementsgracem theimpactof1factivityandbaselinecorrectionontheresultsandinterpretationoftimefrequencyanalysesofeegmegdataacautionarytale
AT lowkathya theimpactof1factivityandbaselinecorrectionontheresultsandinterpretationoftimefrequencyanalysesofeegmegdataacautionarytale
AT fabianimonica theimpactof1factivityandbaselinecorrectionontheresultsandinterpretationoftimefrequencyanalysesofeegmegdataacautionarytale
AT grattongabriele theimpactof1factivityandbaselinecorrectionontheresultsandinterpretationoftimefrequencyanalysesofeegmegdataacautionarytale
AT gyurkovicsmate impactof1factivityandbaselinecorrectionontheresultsandinterpretationoftimefrequencyanalysesofeegmegdataacautionarytale
AT clementsgracem impactof1factivityandbaselinecorrectionontheresultsandinterpretationoftimefrequencyanalysesofeegmegdataacautionarytale
AT lowkathya impactof1factivityandbaselinecorrectionontheresultsandinterpretationoftimefrequencyanalysesofeegmegdataacautionarytale
AT fabianimonica impactof1factivityandbaselinecorrectionontheresultsandinterpretationoftimefrequencyanalysesofeegmegdataacautionarytale
AT grattongabriele impactof1factivityandbaselinecorrectionontheresultsandinterpretationoftimefrequencyanalysesofeegmegdataacautionarytale