Design of a novel tendon-driven manipulator structure based on monolithic compliant rolling-contact joint for minimally invasive surgery

PURPOSE: Compliant mechanisms are commonly used in the design of manipulator and surgical robotic tools for minimally invasive surgery (MIS) thanks to their compactness, ability of miniaturization and lower part count. However, conventional compliant joint has higher internal stiffness, which limits...

Descripción completa

Detalles Bibliográficos
Autores principales: Zhang, Dingzhi, Sun, Yilun, Lueth, Tim C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8354933/
https://www.ncbi.nlm.nih.gov/pubmed/34235629
http://dx.doi.org/10.1007/s11548-021-02442-w
_version_ 1783736682457071616
author Zhang, Dingzhi
Sun, Yilun
Lueth, Tim C.
author_facet Zhang, Dingzhi
Sun, Yilun
Lueth, Tim C.
author_sort Zhang, Dingzhi
collection PubMed
description PURPOSE: Compliant mechanisms are commonly used in the design of manipulator and surgical robotic tools for minimally invasive surgery (MIS) thanks to their compactness, ability of miniaturization and lower part count. However, conventional compliant joint has higher internal stiffness, which limits the bending radius. To overcome this problem, a novel tendon-driven manipulator structure based on monolithic compliant rolling-contact joint (CRCJ) is proposed. METHODS: The proposed rolling-contact mechanism is used to prevent cable slack during actuation, which occurs in conventional compliant joint design. By means of selective laser sintering (SLS) technique, the CRCJ can be fabricated in a monolithic structure, thus granting the CRCJ both the advantages of compliant joints and rolling-contact mechanism. Simulations with nonlinear finite element analysis (FEA) and experiments were conducted to evaluate and compare the mechanical properties of the proposed CRCJ with conventional leaf-type compliant joint including the bending and compliant motion. RESULTS: Experimental results showed that the CRCJ has lower bending stiffness, higher maximum bending angle (over [Formula: see text] ) and a higher compliance compared to conventional compliant hinges, which allows a larger workspace and reduces the possibility of tissue injury. Agreement was also found between the nonlinear FEA and experiments regarding the relation between actuation force and bending angle. A primary prototype of a 3-DOF handheld laparoscopic manipulator with a diameter of 7 mm was further developed. CONCLUSION: A dexterous tendon-driven monolithic manipulator structure based on CRCJ for MIS is proposed. A preliminary prototype of a handheld laparoscopic manipulator demonstrates the capability of the CRCJ for steerable medical devices. However, design improvements based on FEA and application-orientated prototypes considering anatomical requirements still show room for improvements. SUPPLEMENTARY INFORMATION: The online version supplementary material available at 10.1007/s11548-021-02442-w.
format Online
Article
Text
id pubmed-8354933
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-83549332021-08-25 Design of a novel tendon-driven manipulator structure based on monolithic compliant rolling-contact joint for minimally invasive surgery Zhang, Dingzhi Sun, Yilun Lueth, Tim C. Int J Comput Assist Radiol Surg Original Article PURPOSE: Compliant mechanisms are commonly used in the design of manipulator and surgical robotic tools for minimally invasive surgery (MIS) thanks to their compactness, ability of miniaturization and lower part count. However, conventional compliant joint has higher internal stiffness, which limits the bending radius. To overcome this problem, a novel tendon-driven manipulator structure based on monolithic compliant rolling-contact joint (CRCJ) is proposed. METHODS: The proposed rolling-contact mechanism is used to prevent cable slack during actuation, which occurs in conventional compliant joint design. By means of selective laser sintering (SLS) technique, the CRCJ can be fabricated in a monolithic structure, thus granting the CRCJ both the advantages of compliant joints and rolling-contact mechanism. Simulations with nonlinear finite element analysis (FEA) and experiments were conducted to evaluate and compare the mechanical properties of the proposed CRCJ with conventional leaf-type compliant joint including the bending and compliant motion. RESULTS: Experimental results showed that the CRCJ has lower bending stiffness, higher maximum bending angle (over [Formula: see text] ) and a higher compliance compared to conventional compliant hinges, which allows a larger workspace and reduces the possibility of tissue injury. Agreement was also found between the nonlinear FEA and experiments regarding the relation between actuation force and bending angle. A primary prototype of a 3-DOF handheld laparoscopic manipulator with a diameter of 7 mm was further developed. CONCLUSION: A dexterous tendon-driven monolithic manipulator structure based on CRCJ for MIS is proposed. A preliminary prototype of a handheld laparoscopic manipulator demonstrates the capability of the CRCJ for steerable medical devices. However, design improvements based on FEA and application-orientated prototypes considering anatomical requirements still show room for improvements. SUPPLEMENTARY INFORMATION: The online version supplementary material available at 10.1007/s11548-021-02442-w. Springer International Publishing 2021-07-07 2021 /pmc/articles/PMC8354933/ /pubmed/34235629 http://dx.doi.org/10.1007/s11548-021-02442-w Text en © The Author(s) 2021 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Original Article
Zhang, Dingzhi
Sun, Yilun
Lueth, Tim C.
Design of a novel tendon-driven manipulator structure based on monolithic compliant rolling-contact joint for minimally invasive surgery
title Design of a novel tendon-driven manipulator structure based on monolithic compliant rolling-contact joint for minimally invasive surgery
title_full Design of a novel tendon-driven manipulator structure based on monolithic compliant rolling-contact joint for minimally invasive surgery
title_fullStr Design of a novel tendon-driven manipulator structure based on monolithic compliant rolling-contact joint for minimally invasive surgery
title_full_unstemmed Design of a novel tendon-driven manipulator structure based on monolithic compliant rolling-contact joint for minimally invasive surgery
title_short Design of a novel tendon-driven manipulator structure based on monolithic compliant rolling-contact joint for minimally invasive surgery
title_sort design of a novel tendon-driven manipulator structure based on monolithic compliant rolling-contact joint for minimally invasive surgery
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8354933/
https://www.ncbi.nlm.nih.gov/pubmed/34235629
http://dx.doi.org/10.1007/s11548-021-02442-w
work_keys_str_mv AT zhangdingzhi designofanoveltendondrivenmanipulatorstructurebasedonmonolithiccompliantrollingcontactjointforminimallyinvasivesurgery
AT sunyilun designofanoveltendondrivenmanipulatorstructurebasedonmonolithiccompliantrollingcontactjointforminimallyinvasivesurgery
AT luethtimc designofanoveltendondrivenmanipulatorstructurebasedonmonolithiccompliantrollingcontactjointforminimallyinvasivesurgery