The Pink Pad: A Method of Post-Free Distraction During Hip Arthroscopy
Distraction is essential during hip arthroscopy to allow for adequate working space during central and peripheral compartment procedures. Pudendal posts are frequently used with traction boots to achieve distraction, but use of these posts is believed to be associated with the iatrogenic pudendal ar...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2021
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8355178/ https://www.ncbi.nlm.nih.gov/pubmed/34401230 http://dx.doi.org/10.1016/j.eats.2021.04.013 |
_version_ | 1783736715006967808 |
---|---|
author | Perry, Allison K. Gursoy, Safa Singh, Harsh Vadhera, Amar S. Mehta, Nabil Chahla, Jorge |
author_facet | Perry, Allison K. Gursoy, Safa Singh, Harsh Vadhera, Amar S. Mehta, Nabil Chahla, Jorge |
author_sort | Perry, Allison K. |
collection | PubMed |
description | Distraction is essential during hip arthroscopy to allow for adequate working space during central and peripheral compartment procedures. Pudendal posts are frequently used with traction boots to achieve distraction, but use of these posts is believed to be associated with the iatrogenic pudendal area and perineal nerve injuries seen with hip arthroscopy. Current post-free distraction tables are costly and cumbersome. The pink pad positioning device allows for post-free distraction through the creation of friction between the patient, the pad, and the bed. This device can be used with a standard hip arthroscopy table, is easy to learn, allows for adequate distraction, and allows for greater access to the femoral neck during osteochondroplasty, as there is less restriction of the patient’s range of motion without a post present. The purpose of this Technical Note is to describe a method of post-free distraction using the pink pad positioning device. |
format | Online Article Text |
id | pubmed-8355178 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2021 |
publisher | Elsevier |
record_format | MEDLINE/PubMed |
spelling | pubmed-83551782021-08-15 The Pink Pad: A Method of Post-Free Distraction During Hip Arthroscopy Perry, Allison K. Gursoy, Safa Singh, Harsh Vadhera, Amar S. Mehta, Nabil Chahla, Jorge Arthrosc Tech Technical Note Distraction is essential during hip arthroscopy to allow for adequate working space during central and peripheral compartment procedures. Pudendal posts are frequently used with traction boots to achieve distraction, but use of these posts is believed to be associated with the iatrogenic pudendal area and perineal nerve injuries seen with hip arthroscopy. Current post-free distraction tables are costly and cumbersome. The pink pad positioning device allows for post-free distraction through the creation of friction between the patient, the pad, and the bed. This device can be used with a standard hip arthroscopy table, is easy to learn, allows for adequate distraction, and allows for greater access to the femoral neck during osteochondroplasty, as there is less restriction of the patient’s range of motion without a post present. The purpose of this Technical Note is to describe a method of post-free distraction using the pink pad positioning device. Elsevier 2021-07-13 /pmc/articles/PMC8355178/ /pubmed/34401230 http://dx.doi.org/10.1016/j.eats.2021.04.013 Text en © 2021 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). |
spellingShingle | Technical Note Perry, Allison K. Gursoy, Safa Singh, Harsh Vadhera, Amar S. Mehta, Nabil Chahla, Jorge The Pink Pad: A Method of Post-Free Distraction During Hip Arthroscopy |
title | The Pink Pad: A Method of Post-Free Distraction During Hip Arthroscopy |
title_full | The Pink Pad: A Method of Post-Free Distraction During Hip Arthroscopy |
title_fullStr | The Pink Pad: A Method of Post-Free Distraction During Hip Arthroscopy |
title_full_unstemmed | The Pink Pad: A Method of Post-Free Distraction During Hip Arthroscopy |
title_short | The Pink Pad: A Method of Post-Free Distraction During Hip Arthroscopy |
title_sort | pink pad: a method of post-free distraction during hip arthroscopy |
topic | Technical Note |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8355178/ https://www.ncbi.nlm.nih.gov/pubmed/34401230 http://dx.doi.org/10.1016/j.eats.2021.04.013 |
work_keys_str_mv | AT perryallisonk thepinkpadamethodofpostfreedistractionduringhiparthroscopy AT gursoysafa thepinkpadamethodofpostfreedistractionduringhiparthroscopy AT singhharsh thepinkpadamethodofpostfreedistractionduringhiparthroscopy AT vadheraamars thepinkpadamethodofpostfreedistractionduringhiparthroscopy AT mehtanabil thepinkpadamethodofpostfreedistractionduringhiparthroscopy AT chahlajorge thepinkpadamethodofpostfreedistractionduringhiparthroscopy AT perryallisonk pinkpadamethodofpostfreedistractionduringhiparthroscopy AT gursoysafa pinkpadamethodofpostfreedistractionduringhiparthroscopy AT singhharsh pinkpadamethodofpostfreedistractionduringhiparthroscopy AT vadheraamars pinkpadamethodofpostfreedistractionduringhiparthroscopy AT mehtanabil pinkpadamethodofpostfreedistractionduringhiparthroscopy AT chahlajorge pinkpadamethodofpostfreedistractionduringhiparthroscopy |