Cargando…

The Pink Pad: A Method of Post-Free Distraction During Hip Arthroscopy

Distraction is essential during hip arthroscopy to allow for adequate working space during central and peripheral compartment procedures. Pudendal posts are frequently used with traction boots to achieve distraction, but use of these posts is believed to be associated with the iatrogenic pudendal ar...

Descripción completa

Detalles Bibliográficos
Autores principales: Perry, Allison K., Gursoy, Safa, Singh, Harsh, Vadhera, Amar S., Mehta, Nabil, Chahla, Jorge
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8355178/
https://www.ncbi.nlm.nih.gov/pubmed/34401230
http://dx.doi.org/10.1016/j.eats.2021.04.013
_version_ 1783736715006967808
author Perry, Allison K.
Gursoy, Safa
Singh, Harsh
Vadhera, Amar S.
Mehta, Nabil
Chahla, Jorge
author_facet Perry, Allison K.
Gursoy, Safa
Singh, Harsh
Vadhera, Amar S.
Mehta, Nabil
Chahla, Jorge
author_sort Perry, Allison K.
collection PubMed
description Distraction is essential during hip arthroscopy to allow for adequate working space during central and peripheral compartment procedures. Pudendal posts are frequently used with traction boots to achieve distraction, but use of these posts is believed to be associated with the iatrogenic pudendal area and perineal nerve injuries seen with hip arthroscopy. Current post-free distraction tables are costly and cumbersome. The pink pad positioning device allows for post-free distraction through the creation of friction between the patient, the pad, and the bed. This device can be used with a standard hip arthroscopy table, is easy to learn, allows for adequate distraction, and allows for greater access to the femoral neck during osteochondroplasty, as there is less restriction of the patient’s range of motion without a post present. The purpose of this Technical Note is to describe a method of post-free distraction using the pink pad positioning device.
format Online
Article
Text
id pubmed-8355178
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Elsevier
record_format MEDLINE/PubMed
spelling pubmed-83551782021-08-15 The Pink Pad: A Method of Post-Free Distraction During Hip Arthroscopy Perry, Allison K. Gursoy, Safa Singh, Harsh Vadhera, Amar S. Mehta, Nabil Chahla, Jorge Arthrosc Tech Technical Note Distraction is essential during hip arthroscopy to allow for adequate working space during central and peripheral compartment procedures. Pudendal posts are frequently used with traction boots to achieve distraction, but use of these posts is believed to be associated with the iatrogenic pudendal area and perineal nerve injuries seen with hip arthroscopy. Current post-free distraction tables are costly and cumbersome. The pink pad positioning device allows for post-free distraction through the creation of friction between the patient, the pad, and the bed. This device can be used with a standard hip arthroscopy table, is easy to learn, allows for adequate distraction, and allows for greater access to the femoral neck during osteochondroplasty, as there is less restriction of the patient’s range of motion without a post present. The purpose of this Technical Note is to describe a method of post-free distraction using the pink pad positioning device. Elsevier 2021-07-13 /pmc/articles/PMC8355178/ /pubmed/34401230 http://dx.doi.org/10.1016/j.eats.2021.04.013 Text en © 2021 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
spellingShingle Technical Note
Perry, Allison K.
Gursoy, Safa
Singh, Harsh
Vadhera, Amar S.
Mehta, Nabil
Chahla, Jorge
The Pink Pad: A Method of Post-Free Distraction During Hip Arthroscopy
title The Pink Pad: A Method of Post-Free Distraction During Hip Arthroscopy
title_full The Pink Pad: A Method of Post-Free Distraction During Hip Arthroscopy
title_fullStr The Pink Pad: A Method of Post-Free Distraction During Hip Arthroscopy
title_full_unstemmed The Pink Pad: A Method of Post-Free Distraction During Hip Arthroscopy
title_short The Pink Pad: A Method of Post-Free Distraction During Hip Arthroscopy
title_sort pink pad: a method of post-free distraction during hip arthroscopy
topic Technical Note
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8355178/
https://www.ncbi.nlm.nih.gov/pubmed/34401230
http://dx.doi.org/10.1016/j.eats.2021.04.013
work_keys_str_mv AT perryallisonk thepinkpadamethodofpostfreedistractionduringhiparthroscopy
AT gursoysafa thepinkpadamethodofpostfreedistractionduringhiparthroscopy
AT singhharsh thepinkpadamethodofpostfreedistractionduringhiparthroscopy
AT vadheraamars thepinkpadamethodofpostfreedistractionduringhiparthroscopy
AT mehtanabil thepinkpadamethodofpostfreedistractionduringhiparthroscopy
AT chahlajorge thepinkpadamethodofpostfreedistractionduringhiparthroscopy
AT perryallisonk pinkpadamethodofpostfreedistractionduringhiparthroscopy
AT gursoysafa pinkpadamethodofpostfreedistractionduringhiparthroscopy
AT singhharsh pinkpadamethodofpostfreedistractionduringhiparthroscopy
AT vadheraamars pinkpadamethodofpostfreedistractionduringhiparthroscopy
AT mehtanabil pinkpadamethodofpostfreedistractionduringhiparthroscopy
AT chahlajorge pinkpadamethodofpostfreedistractionduringhiparthroscopy