Effect of Tracheal Suctioning on Cuff Pressure in Mechanically Ventilated Patients: a Quasi-Experimental Study

BACKGROUND: Endotracheal tube cuff pressure must be kept in an optimal range, but it might change during some nursing procedures. If the cuff pressure gets outside the normal range, it can cause mucosal damage, insufficient ventilation, and microaspiration. This study aimed to determine the effect o...

Descripción completa

Detalles Bibliográficos
Autores principales: Nazari, Roghieh, Sharif Nia, Hamid, Hajihosseini, Fatemeh, Beheshti, Zahra, Panjoo, Mojgan, Rahmatpour, Pardis
Formato: Online Artículo Texto
Lenguaje:English
Publicado: National Research Institute of Tuberculosis and Lung Disease 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8355932/
https://www.ncbi.nlm.nih.gov/pubmed/34394366
_version_ 1783736847544877056
author Nazari, Roghieh
Sharif Nia, Hamid
Hajihosseini, Fatemeh
Beheshti, Zahra
Panjoo, Mojgan
Rahmatpour, Pardis
author_facet Nazari, Roghieh
Sharif Nia, Hamid
Hajihosseini, Fatemeh
Beheshti, Zahra
Panjoo, Mojgan
Rahmatpour, Pardis
author_sort Nazari, Roghieh
collection PubMed
description BACKGROUND: Endotracheal tube cuff pressure must be kept in an optimal range, but it might change during some nursing procedures. If the cuff pressure gets outside the normal range, it can cause mucosal damage, insufficient ventilation, and microaspiration. This study aimed to determine the effect of endotracheal suctioning on cuff pressure in patients during mechanical ventilation. MATERIALS AND METHODS: This is a quasi-experimental study utilizing repeated measures with a within-subject design. Using a simple convenience sampling method, 61 patients were studied during intubation on mechanical ventilation. Baseline cuff pressure was adjusted to 25 cm H ( 2 ) O. Then, at 15, 30, and 60 minutes’ intervals, cuff pressures were measured once without suctioning and again after suctioning. RESULTS: The results showed a significant change in the mean endotracheal tube cuff pressure during suctioning (p<0.001, d=7.47). During suctioning, cuff pressure exceeded the normal range in 64% of the patients. After suctioning, although endotracheal tube cuff pressure decreased in both conditions, it decreased more significantly (F (2.17, 260.55)=238.19, p<0.001, ν=0.665, d=1.37) in the suctioning condition. CONCLUSION: The results suggest that endotracheal tube cuff pressure increases suddenly and briefly during suctioning, but within 60 minutes after suctioning, it becomes more reduced in suctioning conditions than without suctioning. Therefore, patients are at risk of mucosal damage and microaspiration after and during suctioning, respectively. It is suggested that nurses use continuous cuff pressure regulation methods to prevent potential risks.
format Online
Article
Text
id pubmed-8355932
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher National Research Institute of Tuberculosis and Lung Disease
record_format MEDLINE/PubMed
spelling pubmed-83559322021-08-13 Effect of Tracheal Suctioning on Cuff Pressure in Mechanically Ventilated Patients: a Quasi-Experimental Study Nazari, Roghieh Sharif Nia, Hamid Hajihosseini, Fatemeh Beheshti, Zahra Panjoo, Mojgan Rahmatpour, Pardis Tanaffos Original Article BACKGROUND: Endotracheal tube cuff pressure must be kept in an optimal range, but it might change during some nursing procedures. If the cuff pressure gets outside the normal range, it can cause mucosal damage, insufficient ventilation, and microaspiration. This study aimed to determine the effect of endotracheal suctioning on cuff pressure in patients during mechanical ventilation. MATERIALS AND METHODS: This is a quasi-experimental study utilizing repeated measures with a within-subject design. Using a simple convenience sampling method, 61 patients were studied during intubation on mechanical ventilation. Baseline cuff pressure was adjusted to 25 cm H ( 2 ) O. Then, at 15, 30, and 60 minutes’ intervals, cuff pressures were measured once without suctioning and again after suctioning. RESULTS: The results showed a significant change in the mean endotracheal tube cuff pressure during suctioning (p<0.001, d=7.47). During suctioning, cuff pressure exceeded the normal range in 64% of the patients. After suctioning, although endotracheal tube cuff pressure decreased in both conditions, it decreased more significantly (F (2.17, 260.55)=238.19, p<0.001, ν=0.665, d=1.37) in the suctioning condition. CONCLUSION: The results suggest that endotracheal tube cuff pressure increases suddenly and briefly during suctioning, but within 60 minutes after suctioning, it becomes more reduced in suctioning conditions than without suctioning. Therefore, patients are at risk of mucosal damage and microaspiration after and during suctioning, respectively. It is suggested that nurses use continuous cuff pressure regulation methods to prevent potential risks. National Research Institute of Tuberculosis and Lung Disease 2021-01 /pmc/articles/PMC8355932/ /pubmed/34394366 Text en Copyright© 2021 National Research Institute of Tuberculosis and Lung Disease https://creativecommons.org/licenses/by-nc/4.0/This is an open access article distributed in accordance with the Creative Commons Attribution Non Commercial (CC BY-NC 4.0) license, which permits others to distribute, remix, adapt, build upon this work non-commercially, and license their derivative works on different terms, provided the original work is properly cited, appropriate credit is given, any changes made indicated, and the use is non-commercial. See: http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/)
spellingShingle Original Article
Nazari, Roghieh
Sharif Nia, Hamid
Hajihosseini, Fatemeh
Beheshti, Zahra
Panjoo, Mojgan
Rahmatpour, Pardis
Effect of Tracheal Suctioning on Cuff Pressure in Mechanically Ventilated Patients: a Quasi-Experimental Study
title Effect of Tracheal Suctioning on Cuff Pressure in Mechanically Ventilated Patients: a Quasi-Experimental Study
title_full Effect of Tracheal Suctioning on Cuff Pressure in Mechanically Ventilated Patients: a Quasi-Experimental Study
title_fullStr Effect of Tracheal Suctioning on Cuff Pressure in Mechanically Ventilated Patients: a Quasi-Experimental Study
title_full_unstemmed Effect of Tracheal Suctioning on Cuff Pressure in Mechanically Ventilated Patients: a Quasi-Experimental Study
title_short Effect of Tracheal Suctioning on Cuff Pressure in Mechanically Ventilated Patients: a Quasi-Experimental Study
title_sort effect of tracheal suctioning on cuff pressure in mechanically ventilated patients: a quasi-experimental study
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8355932/
https://www.ncbi.nlm.nih.gov/pubmed/34394366
work_keys_str_mv AT nazariroghieh effectoftrachealsuctioningoncuffpressureinmechanicallyventilatedpatientsaquasiexperimentalstudy
AT sharifniahamid effectoftrachealsuctioningoncuffpressureinmechanicallyventilatedpatientsaquasiexperimentalstudy
AT hajihosseinifatemeh effectoftrachealsuctioningoncuffpressureinmechanicallyventilatedpatientsaquasiexperimentalstudy
AT beheshtizahra effectoftrachealsuctioningoncuffpressureinmechanicallyventilatedpatientsaquasiexperimentalstudy
AT panjoomojgan effectoftrachealsuctioningoncuffpressureinmechanicallyventilatedpatientsaquasiexperimentalstudy
AT rahmatpourpardis effectoftrachealsuctioningoncuffpressureinmechanicallyventilatedpatientsaquasiexperimentalstudy