Cargando…

Clinical Outcomes after Mix-and-Match Implantation of Extended Depth of Focus and Diffractive Multifocal Intraocular Lenses

PURPOSE: To evaluate the clinical outcomes after bilateral mix-and-match cataract surgery using extended depth of focus (EDOF) and diffractive multifocal (DMF) intraocular lenses (IOLs). Setting. Asan Medical Center, Seoul, South Korea. DESIGN: Prospective clinical study. METHODS: Thirty-seven patie...

Descripción completa

Detalles Bibliográficos
Autores principales: Lee, Jae Hyuck, Chung, Ho Seok, Moon, Su Young, Park, So Young, Lee, Hun, Kim, Jae Yong, Tchah, Hungwon
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2021
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8355972/
https://www.ncbi.nlm.nih.gov/pubmed/34394981
http://dx.doi.org/10.1155/2021/8881794
_version_ 1783736856320409600
author Lee, Jae Hyuck
Chung, Ho Seok
Moon, Su Young
Park, So Young
Lee, Hun
Kim, Jae Yong
Tchah, Hungwon
author_facet Lee, Jae Hyuck
Chung, Ho Seok
Moon, Su Young
Park, So Young
Lee, Hun
Kim, Jae Yong
Tchah, Hungwon
author_sort Lee, Jae Hyuck
collection PubMed
description PURPOSE: To evaluate the clinical outcomes after bilateral mix-and-match cataract surgery using extended depth of focus (EDOF) and diffractive multifocal (DMF) intraocular lenses (IOLs). Setting. Asan Medical Center, Seoul, South Korea. DESIGN: Prospective clinical study. METHODS: Thirty-seven patients underwent TECNIS Symfony EDOF IOL (ZXR00) implantation in the dominant eye, and TECNIS +3.25 DMF IOL (ZLB00) implantation in the nondominant eye. Patients were followed up for 3 months; uncorrected and corrected distance visual acuity (UDVA and CDVA), uncorrected intermediate and near visual acuity (UIVA and UNVA), contrast sensitivity, defocus curves, stereopsis, and patient satisfaction were assessed. RESULTS: At 3 months, the mean logarithm of the minimum angle of resolution (logMAR) of UDVA was 0.07 ± 0.09 in EDOF IOL eyes, 0.12 ± 0.11 in DMF IOL eyes, and 0.02 ± 0.05 in both eyes. UIVA was 0.11 ± 0.11 in EDOF IOL eyes, 0.16 ± 0.12 in DMF IOL eyes, and 0.04 ± 0.07 in both eyes. UNVA was 0.25 ± 0.15 in EDOF IOL eyes, 0.22 ± 0.16 in DMF IOL eyes, and 0.13 ± 0.13 in both eyes. Thirty patients (81.1%) were more than satisfied with near vision, and 8 patients (21.6%) complained of severe glare and halo. Spectacle independence for near vision was achieved in 34 patients (91.9%), and 31 patients (83.8%) had better than a 50-second arc of stereopsis. CONCLUSION: Mix-and-match cataract surgery with EDOF and DMF IOL implantation provided good visual outcomes for all distances. Additionally, excellent patient satisfaction was achieved with a high level of spectacle independence and acceptable photic phenomena.
format Online
Article
Text
id pubmed-8355972
institution National Center for Biotechnology Information
language English
publishDate 2021
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-83559722021-08-12 Clinical Outcomes after Mix-and-Match Implantation of Extended Depth of Focus and Diffractive Multifocal Intraocular Lenses Lee, Jae Hyuck Chung, Ho Seok Moon, Su Young Park, So Young Lee, Hun Kim, Jae Yong Tchah, Hungwon J Ophthalmol Research Article PURPOSE: To evaluate the clinical outcomes after bilateral mix-and-match cataract surgery using extended depth of focus (EDOF) and diffractive multifocal (DMF) intraocular lenses (IOLs). Setting. Asan Medical Center, Seoul, South Korea. DESIGN: Prospective clinical study. METHODS: Thirty-seven patients underwent TECNIS Symfony EDOF IOL (ZXR00) implantation in the dominant eye, and TECNIS +3.25 DMF IOL (ZLB00) implantation in the nondominant eye. Patients were followed up for 3 months; uncorrected and corrected distance visual acuity (UDVA and CDVA), uncorrected intermediate and near visual acuity (UIVA and UNVA), contrast sensitivity, defocus curves, stereopsis, and patient satisfaction were assessed. RESULTS: At 3 months, the mean logarithm of the minimum angle of resolution (logMAR) of UDVA was 0.07 ± 0.09 in EDOF IOL eyes, 0.12 ± 0.11 in DMF IOL eyes, and 0.02 ± 0.05 in both eyes. UIVA was 0.11 ± 0.11 in EDOF IOL eyes, 0.16 ± 0.12 in DMF IOL eyes, and 0.04 ± 0.07 in both eyes. UNVA was 0.25 ± 0.15 in EDOF IOL eyes, 0.22 ± 0.16 in DMF IOL eyes, and 0.13 ± 0.13 in both eyes. Thirty patients (81.1%) were more than satisfied with near vision, and 8 patients (21.6%) complained of severe glare and halo. Spectacle independence for near vision was achieved in 34 patients (91.9%), and 31 patients (83.8%) had better than a 50-second arc of stereopsis. CONCLUSION: Mix-and-match cataract surgery with EDOF and DMF IOL implantation provided good visual outcomes for all distances. Additionally, excellent patient satisfaction was achieved with a high level of spectacle independence and acceptable photic phenomena. Hindawi 2021-08-03 /pmc/articles/PMC8355972/ /pubmed/34394981 http://dx.doi.org/10.1155/2021/8881794 Text en Copyright © 2021 Jae Hyuck Lee et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Lee, Jae Hyuck
Chung, Ho Seok
Moon, Su Young
Park, So Young
Lee, Hun
Kim, Jae Yong
Tchah, Hungwon
Clinical Outcomes after Mix-and-Match Implantation of Extended Depth of Focus and Diffractive Multifocal Intraocular Lenses
title Clinical Outcomes after Mix-and-Match Implantation of Extended Depth of Focus and Diffractive Multifocal Intraocular Lenses
title_full Clinical Outcomes after Mix-and-Match Implantation of Extended Depth of Focus and Diffractive Multifocal Intraocular Lenses
title_fullStr Clinical Outcomes after Mix-and-Match Implantation of Extended Depth of Focus and Diffractive Multifocal Intraocular Lenses
title_full_unstemmed Clinical Outcomes after Mix-and-Match Implantation of Extended Depth of Focus and Diffractive Multifocal Intraocular Lenses
title_short Clinical Outcomes after Mix-and-Match Implantation of Extended Depth of Focus and Diffractive Multifocal Intraocular Lenses
title_sort clinical outcomes after mix-and-match implantation of extended depth of focus and diffractive multifocal intraocular lenses
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC8355972/
https://www.ncbi.nlm.nih.gov/pubmed/34394981
http://dx.doi.org/10.1155/2021/8881794
work_keys_str_mv AT leejaehyuck clinicaloutcomesaftermixandmatchimplantationofextendeddepthoffocusanddiffractivemultifocalintraocularlenses
AT chunghoseok clinicaloutcomesaftermixandmatchimplantationofextendeddepthoffocusanddiffractivemultifocalintraocularlenses
AT moonsuyoung clinicaloutcomesaftermixandmatchimplantationofextendeddepthoffocusanddiffractivemultifocalintraocularlenses
AT parksoyoung clinicaloutcomesaftermixandmatchimplantationofextendeddepthoffocusanddiffractivemultifocalintraocularlenses
AT leehun clinicaloutcomesaftermixandmatchimplantationofextendeddepthoffocusanddiffractivemultifocalintraocularlenses
AT kimjaeyong clinicaloutcomesaftermixandmatchimplantationofextendeddepthoffocusanddiffractivemultifocalintraocularlenses
AT tchahhungwon clinicaloutcomesaftermixandmatchimplantationofextendeddepthoffocusanddiffractivemultifocalintraocularlenses